Whether you are out taking a stroll, working on your education, or starting a new business downtown, Berkley, Michigan, in Oakland County, offers a lot to its residents. FLAME Heating, Cooling, Plumbing, and Electrical serves Berkley with the highest quality products for Michigan customers.
Did you know that the Department of Energy has implemented new Energy Efficiency Standards for your residential or commercial water heater of over 55 gallons? If you have an older water heater or you have reason to believe you may need a water heater replacement, now is the time to take action. Call FLAME today for an inspection, repair, or to have a new water heater installed by an expert FLAME technician.
Berkley residents trust FLAME as the airflow pros of Michigan.
Call FLAME today, at (586) 217-2512, or sign up online, and we’ll call you!
Recent Jobs and Reviews in Berkley , MI
Job Locations and Reviews
Responded to emergency call for sewer drain and toilet water flooding throughout entire basement in 50-year-old home. Upon arrival, located main sewer line and cleared blockage causing backup. Verified proper drainage flow through system and confirmed water discharge through exterior PVC drain line. Basement flooding resolved and plumbing system restored to normal operation.
Responded to service call for water heater leaking from top of tank. Upon inspection, identified active leak originating from upper tank connections. Evaluated gas-fired water heater with Easy Set thermostat control and assessed overall unit condition, including copper supply lines showing age-related patina and gas valve assembly. Documented equipment specifications and leak source with photographic evidence for homeowner records.
Responded to service call for tanked water heater producing popping noise in basement. Upon inspection, diagnosed sediment buildup at bottom of tank causing characteristic popping sounds during heating cycles. Performed tank flush procedure by connecting drain hose to drain valve, opening pressure relief valve, and draining accumulated sediment and mineral deposits from unit. Verified all copper supply lines, valves, and connections for proper operation and absence of leaks. Restored unit to normal operation with reduced noise levels.
Completed comprehensive cooling maintenance and tune-up on 6-year-old air conditioning system found to be operating properly. Performed standard preventative maintenance procedures including system inspection, component testing, and filter replacement as part of first-time customer service agreement. All equipment functioning within normal parameters upon completion.
Completed comprehensive GOLD AC inspection on basement coil system installed two years ago. Thoroughly examined evaporator coil, refrigerant lines, electrical connections, and all system components; documented equipment condition with photographs showing proper installation and operational status. All components found to be functioning within normal parameters with no immediate service needs identified.
Responded to service call for water leak in basement affecting furnace and hot water tank installed in 2021. Upon arrival, discovered significant flooding throughout basement area with standing water and extensive water damage to floor surfaces. Inspected HVAC system and found condensate drainage system compromised, with PVC condensate lines showing signs of failure or blockage contributing to water accumulation. Removed furnace access panel to examine internal components including blower motor assembly and drainage connections. Documented extensive water staining on concrete floor beneath and around equipment, indicating prolonged or recurring leak issue. Photographed affected areas showing water intrusion, sediment buildup, and damage to surrounding storage areas. Equipment located in basement showed approximately 5 years of service life. Investigation revealed drainage system malfunction as primary source of water leak affecting both heating equipment and surrounding basement space.
Responded to service call for inoperative air conditioning system. Upon arrival, inspected outdoor condensing unit located in landscaped area adjacent to residence. Unit appeared to be a residential split system with circular top grille design, showing signs of weathering and minor rust discoloration on protective metal components. Performed diagnostic assessment to determine cause of complete system failure and documented equipment condition with photographic evidence for service records.
Completed comprehensive Gold AC inspection on 6-year-old residential cooling system with air handler located in basement. Performed full system evaluation including condenser unit examination, electrical connections check, refrigerant line inspection, and operational testing. Advised customer to maintain clear area around outdoor condenser unit and remove debris and organic matter accumulation observed near equipment to ensure proper airflow and system efficiency.
Completed comprehensive Gold AC inspection on 2015 residential cooling system with air handler located in basement. Performed thorough evaluation of outdoor condenser unit, confirming fan assembly and protective grille in operational condition with minimal debris accumulation, and verified surrounding area clear of obstructions per maintenance protocol.
Responded to a clogged drain call in the master bathroom. Upon arrival, inspected the modern bathroom featuring a freestanding tub with floor-mounted fixtures and an adjacent walk-in shower with marble-look tile walls and hexagonal mosaic floor tile. Assessed the drainage system and successfully cleared the obstruction from the master bathroom drain, restoring proper water flow and drainage function.
Completed comprehensive Gold Plan AC tune-up on residential Daikin condenser unit located on exterior pad. Performed full system inspection including refrigerant level check, electrical component testing, condenser coil cleaning, and airflow verification. All components operating within manufacturer specifications; system ready for cooling season.
Completed annual Gold AC inspection on 5-year-old air conditioning system located in attic. Performed comprehensive tune-up including visual inspection of evaporator coil assembly, which revealed ice and frost buildup along the bottom edge of the coil and drainage pan area. This condition indicates potential airflow restriction, refrigerant charge issues, or drainage problems requiring further diagnosis. Inspected blower compartment and motor assembly, noting loose electrical wiring arrangement within the housing. Documented all findings with photographs for service records. System requires follow-up to address freezing condition and ensure proper operation during cooling season.
Completed comprehensive seasonal cooling maintenance and tune-up on 9-year-old Bryant residential air conditioning system. Performed full system inspection including condenser unit evaluation, verified proper operation of Lennox outdoor unit components, checked fan motor assembly and protective grille condition, inspected electrical connections, measured refrigerant levels and pressures, cleaned condenser coils, verified adequate airflow through louvers, and confirmed system cycling and temperature differential. All components found operating within manufacturer specifications with no deficiencies noted. System confirmed working properly and ready for cooling season operation.
Responded to service call for AprilAire Model E100 whole-home dehumidifier displaying E4 error code and failing to maintain operation after startup. Inspected unit in basement, documented equipment condition and manufacturer specifications. Low temperature sensor/frost sensor identified as required component for repair, with part to be supplied under existing purchase order for future installation.
Completed installation of 3.5-ton air conditioning unit with new evaporator coil on left side of residence. System was positioned in narrow side yard area against privacy fencing on gravel base, with unit properly secured and leveled. Electrical reconnection was performed in accordance with code requirements. Mechanical and electrical permits were requested and processed for the installation. System was flushed, tested, and verified operational upon completion.
Conducted on-site assessment for complete HVAC system replacement in basement location. Existing equipment is 20 years old and has reached end of service life. Evaluated electrical panel capacity and confirmed adequate amperage available for new system installation. Inspected existing ductwork, water heater clearances, and utility infrastructure to determine optimal equipment placement and sizing requirements. Documented current system configuration including electrical connections, ventilation pathways, and available installation space. Provided comprehensive replacement quote including equipment specifications and installation scope.
Completed comprehensive Gold AC Inspection on a one-year-old residential air conditioning system with outdoor condenser unit located on concrete pad and air handler positioned in basement. Performed multi-point inspection including visual assessment of condenser unit condition, verification of electrical connections and utility components, evaluation of refrigerant lines and condensate drainage system, and confirmation of proper equipment operation and airflow. Unit found to be functioning within normal parameters with no immediate service concerns identified.
Completed comprehensive Gold AC Inspection on residential outdoor condensing unit with cylindrical cabinet design and vertical louver configuration. Performed full system tune-up including inspection of refrigerant lines, electrical connections, and condenser coil condition. Replaced air filter showing moderate dust accumulation and discoloration in multiple segments of hexagonal frame assembly, ensuring optimal airflow and system efficiency for continued operation.
Responded to service call for 5-year-old furnace in basement displaying "G F S flame fail in run mode" error. Performed comprehensive tune-up maintenance including system diagnostics, flame sensor inspection and cleaning, burner assembly examination, and verification of proper ignition sequence. Tested gas pressure at meter (37.8" reading documented), inspected intake/exhaust venting at exterior termination point, confirmed all safety controls operational, and cycled unit multiple times to verify error code resolution and stable operation.
Completed air conditioning system startup and commissioning for newly installed HVAC equipment. Verified proper installation of attic-mounted components including ductwork, insulation, and structural supports. Programmed and configured Honeywell Home HumidiPRO digital thermostat to system specifications, confirmed display functionality and control settings. System tested and operational, ready for service.