Clinton Township is the most populated township in Michigan, and it has the most parks of any city or township in Macomb County, MI. Perhaps most notably is the multi-million dollar George George Park which features 30 acres of playgrounds, walking paths and a picnic pavilion. With all that land to roam, who has time to worry about seasonal heating and cooling? The HVAC experts at FLAME are the best choice for emergency repairs and appliance installation for Clinton Township.
During the summertime, Clinton Township hosts the Gratiot Cruise. The cruise features a parade of classic cars and is a free public event for friends and families, from Macomb County and beyond. With average summer temperatures reaching 82°F, make sure your house is cool with a high-efficiency air conditioner installed by our FLAME experts.
FLAME can also help you prepare your home for winter. The average temperature of Clinton Township winters can get as low as 15°F. Make sure your home is warm enough by calling a FLAME expert today for an in-home inspection, and, if you need service, FLAME offers our Clinton Township customers nothing but the highest-quality work.
Why choose FLAME for your Clinton Township heating and cooling needs?
Because FLAME does high-quality HVAC work and install only the most reliable Bryant® products, and it’s all backed by a 100% satisfaction guarantee.
Call FLAME today, at (586) 217-2512, or sign up online, and we’ll call you!
Recent Jobs and Reviews in Clinton Township , MI
Job Locations and Reviews
Responded to service call for non-operational air conditioning system. Upon arrival, performed comprehensive assessment of existing HVAC equipment located in basement and backyard. Evaluated aging furnace and air conditioning components, including inspection of ductwork, copper refrigerant lines, and associated piping systems with shut-off valves. Documented current system configuration showing older green metal furnace unit with visible oxidation on copper piping and flexible metallic ductwork. Provided detailed estimate for complete HVAC system replacement to address non-functional outdoor condensing unit and related equipment failure.
Responded to service call for cooling system evaluation on 10+ year old equipment located in basement mechanical space. Upon inspection, diagnosed failed compressor unit requiring full system replacement rather than individual component repair. Assessed existing air handler, ductwork configuration, and refrigerant line routing. Provided comprehensive full system replacement estimate to homeowner, documenting current equipment condition and recommended replacement specifications for complete HVAC system upgrade.
Performed pre-replacement evaluation on 10+ year old cooling system located in basement. Upon inspection, discovered heavily corroded electrical connector with significant oxidation on prongs, creating potential safety hazard and contributing to system malfunction. Inspected blower assembly and found unit operational but showing normal wear consistent with age, with accumulated dust and debris present in housing and ductwork.
Completed comprehensive tune-up and inspection on 10+ year old furnace and air conditioning system located in basement. Performed standard maintenance procedures including checking condenser unit operation, inspecting fan grille assembly, verifying proper airflow, and evaluating overall system performance. All equipment found to be functioning within normal parameters with routine weathering noted on outdoor condenser unit consistent with age of system.
Provided estimate for replacement of existing 10+ year old air conditioning system and natural gas furnace currently located in basement. Current Lennox equipment is operational but nearing end of service life. Evaluated existing ductwork, thermostat, and ventilation configuration to determine replacement specifications and equipment sizing requirements.
Performed city certification inspection on forced air furnace and water heater located on main level. Inspected gas valve assembly and pressure regulator on heating equipment, verifying proper operation and safety compliance. Examined all visible piping connections, gas lines, and mechanical components for leaks and proper installation. Verified equipment functionality and documented current condition of system components for certification purposes. All equipment met municipal safety standards and passed inspection requirements.
Responded to callback for AC system continuing to cycle on and off following previous service where contactor was replaced and low refrigerant was addressed. Upon arrival, connected manifold gauges to verify system pressures and operating parameters. Investigated condenser unit for reported loud noises and short cycling issue. System monitored through multiple cycles to diagnose intermittent operation and assess compressor performance, refrigerant charge levels, and electrical components to determine root cause of continued cycling problem.
Completed comprehensive HVAC estimate for full system replacement at residential property. Evaluated existing outdoor air conditioning condenser unit and assessed electrical service configuration including dual meter setup and disconnect panels to determine compatibility requirements for new equipment installation. Documented current system conditions and site specifications to provide accurate equipment sizing and installation planning for furnace and air conditioning replacement.
Completed full HVAC system installation including new outdoor condensing unit positioned on concrete pad against exterior wall. Unit was properly mounted, refrigerant lines connected, and system charged to manufacturer specifications. Comprehensive system diagnostics performed using calibrated testing equipment, confirming optimal operating temperatures, pressures, and performance parameters across all components.
Responded to report of AC breaker tripping repeatedly over a two-day period. Upon inspection, found outdoor condensing unit with 60-amp CU-AL rated circuit breaker and electrical components showing significant weathering, corrosion, and oxidation. Documented condition of contactor, disconnect switch, and wire terminals at top of unit. Extensive rust present on metal fan guard and housing surfaces indicated prolonged environmental exposure. Photographed electrical connections and breaker assembly for service records.
Responded to service call for loud noises coming from 2022 AC condenser unit located in basement. Upon arrival, performed diagnostic testing using refrigerant leak detector and inspected control board wiring connections. Examined thermostat wiring configuration at control panel, checking COM, SAT, HEAT, and COOL terminal connections for proper seating and signs of arcing or deterioration. Verified all wire terminations were secure and heat-shrink connections were intact. Completed system evaluation and documented findings with photographs for service records.
Completed comprehensive Gold AC tune-up and inspection on Bryant outdoor condensing unit. System was operating properly upon arrival; performed standard cooling maintenance protocol including cleaning condenser coils, checking refrigerant levels, testing electrical components, inspecting fan operation, and verifying overall system performance. Unit is in good working condition with no issues identified.
Completed full HVAC system installation including a 90,000 BTU high-efficiency furnace, 3-ton air conditioning unit with rear discharge configuration, and whole-home humidifier in basement mechanical room. Installed all required PVC venting and drainage piping, connected ductwork, performed electrical reconnection, and verified proper system operation. Mechanical permit obtained and utility rebate applications submitted for energy-efficient equipment upgrade.
Completed comprehensive Gold AC Inspection on 2011 residential air conditioning system with basement-located air handler. Performed visual inspection of outdoor condenser unit, which showed good overall condition with no visible damage, secure fan guard assembly, and proper mounting on level concrete pad. Verified system operational status and documented equipment condition through photographic records.
Completed Gold AC Inspection and routine maintenance on Lennox outdoor condensing unit. Performed comprehensive system evaluation including refrigerant pressure checks, electrical component testing, capacitor inspection, and contactor examination. Cleaned condenser coils, verified proper airflow through louvers, inspected fan motor operation and blade condition. Checked refrigerant line connections for leaks, confirmed proper drainage, and verified thermostat communication. All components operating within manufacturer specifications with no deficiencies noted. Unit found in excellent condition consistent with newer equipment age.
Completed installation of 2-ton air conditioning unit with matching evaporator coil in front-return configuration. Reconnected system to existing furnace and ductwork, installed condensate pump, and verified proper refrigerant charge and airflow. Mechanical permit obtained for HVAC components only, with electrical work to be completed by licensed electrician at later date.
Completed comprehensive HVAC tune-up inspection on heating system over 10 years old, including thorough examination of humidifier, thermostat, and hot water tank components. Inspected A.O. Smith 50-gallon natural gas water heater (Model GCG-50 400, manufactured 03/30/2017) with 40,000 BTU/HR input rating, verifying proper operation of gas connections, copper supply lines with shutoff valves, and venting system. All equipment found operating within normal parameters with no immediate service requirements identified.
Completed comprehensive Gold AC Inspection on one-year-old cooling system located in basement. Performed full preventive maintenance tune-up including inspection of outdoor condenser unit, verification of proper fan operation, and system performance evaluation. Unit found to be in excellent working condition with no deficiencies noted; all components operating within manufacturer specifications.
Completed comprehensive Gold AC Inspection on single outdoor heat pump unit with indoor air handler located in basement. Performed full system evaluation including visual inspection of outdoor unit components, verified fan operation and protective grille integrity, and documented equipment condition through photographic records. All equipment confirmed operational at time of inspection with homeowner present.
Conducted on-site assessment for complete air conditioning system replacement at residential property. Evaluated existing electrical infrastructure including meter location and panel box positioning on exterior brick wall, and assessed interior ceiling access point for potential ductwork modifications and equipment installation routing. Documented current site conditions to develop comprehensive replacement specifications for new AC unit installation.