Dearborn in Wayne County is the 8th largest city in Michigan and is still growing. In fact, Dearborn received a top rating for economic development from the University of Michigan-Dearborn’s Center for Innovation Research for a fifth year in a row. A city with standards this high should settle for nothing less than the best when it comes to heating and cooling. FLAME is proud to provide quality HVAC maintenance, installation and repair for Dearborn residents.
With temperatures averaging around 18°F in the winter and 85°F in the summer, Dearborn residents need heating and cooling they can rely on. After all, a city built on industry deserves an HVAC company that works the hardest, and FLAME has being doing just that for over 60 years. FLAME technicians complete thorough HVAC installations, maintenance, and repairs. We are your airflow pros for all your heating and cooling needs.
The city was the home of Henry Ford and is the world headquarters of the Ford Motor Company; not a small achievement. FLAME carries on Dearborn’s spirit of innovation in all of its HVAC products from Bryant®. We do this by providing high-quality and high-efficiency gas furnaces and air conditioners to keep your home comfortable. Depending on your needs, ask a FLAME representative about our Bryant HYBRID HEAT® dual-fuel gas and electrical whole-home systems.
Protect Your Family with an Aprilaire Dehumidifier
With rapidly changing temperatures and an abundance of surrounding water, a dehumidifier is essential for small homes and condominiums in Michigan.
Here’s a few reasons to install an Aprilaire dehumidifier:
-
Eliminate musty smells
-
Eliminate clammy skin
-
Prevent growth of molds that can trigger allergy or asthma symptoms
-
Eliminate undue energy costs when cooling your home to achieve ideal humidity levels
-
It’s less expensive than operating a portable unit and there are no trays to empty
-
Protect wood moldings, floors, windows and furniture from warping and rot that occurs from too much moisture
Choose FLAME for all of your heating and cooling needs in Dearborn, Michigan.
Call us today or sign up online and we’ll call you!
(888) 234-2340
Recent Jobs and Reviews in Dearborn , MI
Job Locations and Reviews
Responded to service call for 12-year-old Daikin mini-split system in upper bedroom with no heating or cooling function and clicking noise upon startup attempt. Upon arrival, conducted diagnostic assessment of both indoor head unit and outdoor condenser. Inspection revealed heavily corroded refrigerant line connections at outdoor unit with significant rust on brass fittings and deteriorated insulation on copper lines. Outdoor unit housing showed extensive weathering and debris accumulation on concrete pad. Performed system diagnostics using digital testing equipment to assess electrical and refrigerant system functionality. Documented existing conditions of remote control, refrigerant connections, and overall system deterioration for customer records and recommended repair options.
Responded to service call for leak detection and moisture assessment in residential condo unit. Performed comprehensive inspection of plumbing fixtures and water supply connections in bathroom and kitchen areas. Examined toilet water supply line, shut-off valve, and flexible braided connection for signs of leakage or deterioration. Inspected under-sink plumbing including P-trap assembly, drain connections, and dual braided stainless steel supply lines with chrome shut-off valves. Tested all connections for active leaks and checked surrounding areas for moisture intrusion or water damage. Documented all plumbing fixtures and connections with photographic evidence. Provided repair recommendations and prepared two quote options for necessary corrective work totaling required repairs and preventive maintenance measures.
Responded to no cooling complaint on central air conditioning system. Upon arrival, performed diagnostic testing using digital multimeter to check electrical components and measure voltage readings. Identified system failure preventing proper operation. Completed necessary repairs to restore cooling function. System tested and verified operational before departure.
Completed heat pump system replacement at DNR air quality monitoring station, a 12' x 12' structure located behind a school. Removed and properly reclaimed refrigerant from existing indoor and outdoor units, then recycled old equipment according to environmental regulations. Flushed and repurposed existing line set, reused equipment stand, and updated electrical components including power supply, disconnect, and GFI protection. Installed new heat pump system with handheld controller for remote operation and monitoring of the air quality station.
Completed comprehensive Gold AC inspection on 13-year-old residential air conditioning system with air handler located in basement. Performed thorough evaluation of outdoor condenser unit, verified proper operation of all components including fan assembly and compressor, inspected electrical connections, checked refrigerant levels, and assessed overall system performance. Unit found to be operating within normal parameters with no immediate service requirements identified.
Completed comprehensive Gold AC inspection on residential split system less than one year old. Performed thorough evaluation of outdoor condensing unit and basement-located air handler, confirming all components operating within normal parameters. Inspected exterior unit housing, verified proper airflow through ventilation louvers, checked fan operation and grille assembly, and documented equipment condition with no visible damage or operational concerns noted. System confirmed fully functional with homeowner present.
Provided estimate for conversion from leaking 7-year-old traditional tank water heater to tankless unit in basement location. Assessed existing natural gas supply line, venting requirements, and electrical connections needed for tankless installation. Evaluated basement space constraints and determined optimal mounting location for new tankless system, considering proximity to existing gas line and adequate clearance for proper ventilation and code compliance.
# Emergency Plumbing Repair - Basement Pipe Leak Responded to an active water leak in the basement caused by a cracked vertical PVC drain pipe. Upon arrival, discovered a significant vertical split running along the length of the pipe with heavy rust-colored staining indicating ongoing water seepage. Temporary measures were implemented by placing absorbent towels at the base of the pipe to contain water damage to the basement floor area. Documented the extent of the damage through photographic evidence, capturing the crack location at the coupling joint and the rust discoloration pattern. The pipe showed signs of deterioration with metal corrosion visible within the PVC system, suggesting contamination or internal component failure. The leak was confined to the basement utility area with no indication of spread to upper floors at the time of service. Assessed the vertical pipe running from floor to ceiling and identified the compromised section requiring replacement. The rust staini
Responded to emergency call for burst pipes in basement caused by freezing conditions. Upon arrival, conducted thorough inspection of affected area and documented damage to plumbing infrastructure. Multiple frozen pipes had ruptured, resulting in water damage to basement ceiling and surrounding structural components. Photographed exposed ceiling cavity showing damaged pipe sections, wooden support beams, and affected building materials. Documented water intrusion points and extent of damage to acoustic ceiling tiles and adjacent wall surfaces. Assessed basement utility area where burst pipes were located, noting water damage patterns on concrete walls and floors. Provided comprehensive visual documentation of all damaged components for insurance claim purposes, including detailed photographs of compromised plumbing system and resulting structural impact.
Completed full HVAC system replacement including removal of existing low boy furnace and installation of new 70,000 BTU furnace with 2-ton air conditioning unit configured for right-side placement. Installed new thermostat, humidifier, and liner as part of the complete system upgrade. Configured white PVC condensate drainage system with proper pitch and secure connections using purple primer, running both vertical and horizontal lines to ensure efficient moisture removal. Installed copper refrigerant lines with appropriate insulation and flexible metal conduit for electrical connections. Mounted control panel and wiring in compliance with mechanical and electrical permit requirements. System achieved AHRI certification number 21558462, qualifying for utility rebate program. All components properly secured and labeled with specification plates and safety warnings. Installation completed in unfinished utility space with drainage system terminating at flush mount pump kit for condensate r
Performed main sewer line cleanout service in preparation for property sale. Successfully snaked the main drain line to remove blockages and restore proper flow through the system. Accessed the cleanout point via floor drain assembly and cleared the line to ensure full functionality of the wastewater drainage system.
Completed Gold AC Inspection on a 2-year-old Lennox air conditioning system with air handler located in basement. Verified system operational status, inspected outdoor condenser unit positioned on concrete pad with clear surroundings and adequate clearances, confirmed proper electrical connections and conduit installation, and documented equipment condition with unit showing normal wear consistent with age. All components found operating within normal parameters with no immediate service concerns identified.
Completed comprehensive Gold AC inspection on 7-year-old system with basement evaporator coil configuration. Performed thorough evaluation of outdoor condensing unit, verified operational status of fan motor and compressor, inspected condenser coil louvers for airflow efficiency, and documented equipment condition through photographic records. Unit found to be in satisfactory operational condition with normal outdoor weathering present.
Installed bathroom exhaust fan in bedroom-adjacent bathroom area with proper ventilation routing. Upgraded electrical system to include GFCI-protected outlet with integrated switch for fan control, plus additional standard duplex receptacle on tiled bathroom wall. Work included running new electrical circuit, mounting ventilation grille, and ensuring all components meet current electrical code requirements for bathroom moisture protection.
Provided estimate for complete HVAC system replacement including new furnace and air conditioning unit to replace 40-year-old equipment located in basement. Existing furnace currently operational but due for replacement due to age; air conditioning system will be new installation with outdoor condenser unit mounted on exterior brick wall where mounting brackets are visible.
Performed AC system startup on outdoor condensing unit located at basement level. Connected Fieldpiece diagnostic manifold gauges and verified refrigerant pressures and temperatures within manufacturer specifications. Inspected electrical connections at disconnect boxes, refrigerant line sets, and outdoor unit. System operational and cooling properly. Customer inquiry regarding property violation requires follow-up discussion.
Responded to service call for toilet tank not refilling after flush. Upon inspection, identified faulty fill valve assembly preventing proper water flow into tank. Replaced defective fill valve mechanism and tested flush cycle to ensure proper tank refill and water shutoff at appropriate level.
Completed comprehensive Gold AC Inspection and tune-up on 7-year-old residential air conditioning system located on north side of property. Unit is a beige cylindrical condenser with top-discharge fan configuration, mounted on rubber isolation pad against brick exterior wall. Performed full system evaluation including visual inspection of condenser cabinet, coil fins, fan assembly, and electrical connections. Verified proper refrigerant line routing and insulation integrity. Checked condenser pad levelness and stability. Noted presence of seasonal debris including fallen leaves and dried vegetation around unit base and on concrete pad. Inspected manufacturer data plate for model and serial number documentation. Evaluated overall unit condition consistent with 7-8 years of operation. System operational and functioning within normal parameters upon completion of maintenance service.
Removed leaking brass trip waste and drum trap assembly from bathtub and replaced with new PVC trip waste and P-trap configuration. Work required access through basement ceiling to remove deteriorated drainage components and install updated plumbing system to eliminate active leak. All connections tested and verified operational with one-year labor warranty provided.
Responded to bathtub drain leak causing water to drip onto basement floor. Accessed plumbing system through basement ceiling to locate source of leak at drain pipe connection. Upon inspection, identified deteriorated pipe joint and loose fitting at the tub drain assembly where water was escaping during drainage. Disassembled affected section, cleaned connection points, and reinstalled drain piping with proper sealing. Replaced worn gaskets and tightened all compression fittings at the manifold junction. Tested system by running water through the tub drain while monitoring for leaks from basement below. Verified complete repair with no further water discharge to basement floor.