Bordered by Livonia and Dearborn Heights, Westland, Michigan is a large city in Wayne County, with over 80,000 residents. That’s a lot of Southeastern Michigan homes with HVAC systems! FLAME is proud to serve every last one of them, by offering high quality heating and cooling products.
Wintertime in Westland brings beautiful snow, and fun events, like the Wayne County Lightfest, a beautiful lights display during the holiday season. Unfortunately, wintertime in Michigan can also bring harsh cold through Michigan. Prepare for wintertime temperature lows with a new gas furnace from the HVAC pros—FLAME.
Did you know that eliminating excess humidity from your home is essential to your family’s health and comfort? An Aprilaire whole-home dehumidifier is the answer for getting rid of mold, mildew, airborne bacteria, and musty odors. Contact FLAME today, and protect your family!
Call FLAME today, at (586) 217-2512, or sign up online, and we’ll call you!
Recent Jobs and Reviews in Westland , MI
Westland, MI at a glance
Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Westland, MI between May 2026 and July 2026.
The most recent job was on July 21, 2026.
Flame Heating, Cooling, Plumbing, Electrical has completed 60 jobs in Westland, MI in the last 12 months.
Job Locations and Reviews
Responded to no cooling call on 16-year-old residential air conditioning system. Upon inspection, discovered severe thermal damage to wiring at outdoor unit's circuit breaker connection. Gray wire insulation was severely burned, melted, and charred with exposed conductor, indicating dangerous electrical failure and fire hazard. The 10-amp Square D breaker showed heavy dust accumulation and signs of extended service life. Documented electrical damage with photographs showing compromised wire integrity at terminal block. System was inoperable due to failed electrical connection preventing power delivery to compressor. Recommended immediate electrical repairs to restore safe operation and prevent potential fire risk.
Performed routine maintenance flush on a Bradford White 50-gallon natural gas water heater, model RG250T6N. Drained sediment buildup from tank bottom through drain valve to improve heating efficiency and extend unit lifespan. Verified proper operation of temperature and pressure relief valve, inspected all visible connections for leaks, and confirmed manufacturer labels and safety warnings remain legible and intact.
Completed routine furnace certification and tune-up on Goodman furnace located in kitchen for residential home sale requirement. Performed comprehensive inspection of all internal components including blower motor assembly, gas valve manifold, burner assembly, and electrical connections per city mechanical contractor certification standards. All systems tested and verified operational, with official certification form completed and unit approved for sale transfer.
Responded to no airflow complaint on 6-year-old residential air conditioning system. Performed diagnostic inspection of outdoor condensing unit located in backyard and indoor components. Inspected electrical compartment, capacitor, contactor, and associated wiring connections. Verified proper operation of thermostat on first floor and traced system controls from basement to outdoor unit. Renewed maintenance agreement on site per homeowner request.
Completed preventative maintenance tune-up on 4-year-old residential HVAC system with air handler located on main floor. Performed comprehensive inspection of outdoor condensing unit and indoor components, verified system operation and cooling functionality, and confirmed all equipment operating within normal parameters at time of service.
Responded to no air flow complaint on 4-year-old residential air conditioning system located in office/second bedroom. Performed diagnostic evaluation of outdoor condensing unit mounted on exterior wall. Inspected unit housing, louvers, and ventilation grilles for obstructions or damage. Verified proper airflow through condenser coils and assessed overall system operation to restore cooling capacity.
Responded to mechanical code violation by installing continuous insulation jacket on exposed refrigerant line near evaporator coil. The copper refrigerant piping that was previously bare near the coil connection point has been properly insulated to meet local building code requirements and prevent condensation issues.
Provided estimate for complete HVAC system replacement in basement location. Existing 36-year-old natural gas furnace is non-operational and requires full system replacement including furnace and air conditioning components. Assessed current equipment configuration, ductwork connections, and utility access to determine proper sizing and installation requirements for new system.
Responded to service call for central air conditioning system with poor cooling performance. Conducted thorough inspection of outdoor condenser unit and associated electrical components to diagnose cooling deficiency. Based on previous service history indicating potential refrigerant leak, performed leak detection testing and system performance evaluation to determine root cause of reduced cooling capacity.
Completed NSP AC inspection on 4-year-old York air conditioning system located in basement with outdoor condenser unit installed on gravel pad against exterior wall. Performed comprehensive system evaluation including visual inspection of condenser unit, electrical connections, and associated components mounted on building exterior. All equipment found operating within normal parameters with no deficiencies noted during inspection.
Completed HVAC system estimate for furnace replacement at property currently equipped with boiler and air conditioning system. Verified existing ductwork infrastructure and proper venting configuration to ensure compatibility with proposed Bryant furnace installation. Documented current basement-mounted furnace unit with insulated supply ductwork and existing digital thermostat control system. Assessed utility room layout, clearances, and mechanical requirements for seamless equipment replacement while maintaining proper airflow distribution throughout the residence.
Provided comprehensive estimate for complete HVAC system replacement including natural gas furnace located in basement and outdoor air conditioning unit. Existing 10+ year old equipment is non-operational and requires full replacement to restore heating and cooling capabilities to the residence.
Installed GFCI electrical outlet in outdoor concrete surface location. Mounted weatherproof cover and junction box flush with existing concrete patio area to provide protected power access in exterior environment. Verified proper grounding and weather sealing for code compliance.
Responded to a flame violation notice regarding improper water heater installation. Terminated and properly routed the drain pan discharge line to the crawl space as required by code. Addressed chimney penetration issues by applying mortar around the ductwork where it passes through the ceiling to seal gaps and prevent potential hazards. Documentation photos captured the water heater unit with exposed drain line termination on parquet flooring and the metal ductwork penetration through the ceiling showing previous water damage and staining around the penetration points that required sealing.
Completed on-site assessment for bathtub replacement in first floor bathroom of 1960s ranch-style home. Documented existing white subway-tiled shower/tub enclosure with chrome fixtures including temperature control valve, tub spout, and overhead shower head. Evaluated current bathtub condition, wall-mounted grab bar placement, and recessed shelf niches built into tile surround. Photographed existing plumbing fixtures, tile work, and bathroom configuration to provide accurate estimate for tub removal and replacement project.
Responded to service call for toilet replacement at residential property. Upon arrival, assessed existing toilet fixture and confirmed homeowner's request for complete unit replacement. Successfully removed old toilet, inspected flange and wax ring seal, and installed new toilet fixture with proper sealing and secure mounting to ensure leak-free operation.
Installed a weatherproof GFCI outlet in an Intermatic Type 3R rated enclosure on the building exterior. The ground fault circuit interrupter was properly wired, tested for functionality with the LED indicator confirming power, and the hinged clear protective cover was secured to maintain weather resistance per code requirements.
Completed comprehensive Gold AC Inspection on a 1-year-old air conditioning system located in the utility room. Performed thorough examination of evaporator coil, noting moderate dust and debris accumulation on coil fins with some organic matter present. Inspected air filtration system, observing moderately soiled filter media with visible dust and particle buildup but no structural damage to filter or frame. All components photographed and documented for maintenance records, with system operational at time of inspection.
Completed Gold AC inspection on a single 2021 outdoor condensing unit with air handler located in basement. Unit operational at time of inspection. Observed moderate debris accumulation on condenser coil fins, particularly in upper sections, with environmental dust and lint buildup noted during visual assessment. Exterior cabinet and protective wire grilles in good condition with no visible damage to housing or components. Homeowner advised that uninterruptible service option was affected by recent DTE furnace installation and expressed interest in exploring restoration options for this service feature.
Completed comprehensive five-year furnace inspection in basement and evaluated outdoor Bryant air conditioning condenser unit as part of prepaid maintenance visit. Inspected electrical components including capacitor, contactor, and associated wiring connections within outdoor unit, documenting condition of all terminals and electrical pathways. Verified outdoor condenser placement on pad, assessed unit cleanliness, and confirmed proper clearance from surrounding vegetation and debris.