
The city of Center Line in Macomb County, Michigan prides itself on its close-knit community, with a small-town feel and many local restaurants, bakeries, and mom & pop shops. FLAME Heating, Cooling, Plumbing and Electrical believes in community values and provides Center Line residents with the best heating and cooling services money can buy.
That’s why FLAME installs only the most reliable and highest efficiency HVAC products from Bryant®. Call FLAME today so we can help you find the best comfort system for your home as well as your budget.
Center Line residents trust the airflow pros at FLAME for all their heating and cooling needs. Call FLAME, at (586) 217-2512, or sign up online and we’ll call you!
Recent Jobs and Reviews in Center Line , MI
Center Line, MI at a glance
Flame Heating, Cooling, Plumbing, Electrical has completed 17 jobs in Center Line, MI between March 2026 and May 2026.
The most recent job was on May 19, 2026.
Flame Heating, Cooling, Plumbing, Electrical has completed 57 jobs in Center Line, MI in the last 12 months.
Job Locations and Reviews
Completed comprehensive Gold AC inspection on 3-year-old single-unit Lennox system with basement-located air handler. Performed full multi-point inspection of outdoor condenser unit positioned on concrete pad with proper clearance and landscaping rock surround, verified operational status of all components including fan motor and coil assembly. Inspected indoor air handler equipped with Aprilaire humidistat control, confirmed proper airflow, checked electrical connections, verified refrigerant levels, cleaned condenser coils, and documented system performance with NADCA certification label present indicating previous maintenance compliance. All equipment found operating within normal parameters with no immediate service needs identified.
Completed Gold AC inspection on single Lennox air conditioning system with air handler located in first floor utility closet and condenser unit positioned on exterior pad. Performed comprehensive system evaluation including electrical voltage testing, which confirmed proper operation at 244.8 VAC. Inspected condenser unit components, verified clearances around outdoor unit, examined refrigerant lines, electrical connections, and disconnect box. All equipment found operating within normal parameters with no immediate service concerns identified.
Completed comprehensive inspection and tune-up on 2022 Lennox furnace system located in basement utility area. Performed full system diagnostic including visual inspection of heat exchanger, blower assembly, and all electrical connections; verified proper operation of gas valve and ignition system; checked and cleaned flame sensor; inspected and confirmed proper venting and condensate drainage through PVC piping; tested safety controls and limit switches; measured temperature rise across heat exchanger within manufacturer specifications; verified adequate combustion air supply; inspected ductwork connections for proper sealing. System operating efficiently with no deficiencies noted at time of inspection.
Responded to service call for no hot water and leaking 75-gallon tanked water heater approximately 8-10 years old. Upon inspection, confirmed active leak from tank and determined unit had reached end of serviceable life. Disconnected existing water heater, removed failed unit, and installed replacement 75-gallon residential water heater. Reconnected copper supply lines with brass fittings and shut-off valves, verified all connections for proper seal and operation, and tested system to ensure adequate hot water delivery throughout residence.
Completed two-day installation of Navien combination boiler system in residential basement mechanical room. Installed wall-mounted combi unit with comprehensive copper piping network, including supply and return lines, expansion tank, pressure relief components, and water filtration system. Routed and secured all piping with proper support brackets, installed necessary valves and fittings, and integrated system with existing plumbing infrastructure. Permit requested and all work performed to code specifications.
Completed gas line repairs in basement utility area. Inspected and serviced copper gas piping system with multiple vertical and horizontal runs, including brass fittings, valves, and pressure gauges mounted to cinder block walls. Verified integrity of connections and tested system for proper operation and safety compliance.
Completed three-day installation of Daikin three-head mini-split system at residential property. Mounted exterior condenser unit on white concrete block wall with refrigerant lines and electrical conduit run along exterior surface to disconnect box near roofline. Installed indoor air handler units in multiple rooms with proper wall mounting and connection to outdoor unit. Ran new dedicated electrical circuit to support system requirements. Obtained mechanical and electrical permits prior to installation. System tested and operational upon completion.
Completed estimate for mini split installation requiring gas line extension to second floor. Assessed existing gas meter location and mapped routing path along exterior wall up approximately 25 feet to second-floor penetration point. Proposed installation includes running new gas piping from existing meter through exterior wall-mounted route with appropriate supports and code-compliant fittings to supply future mini split equipment on upper level.
Completed comprehensive Gold AC Inspection on Lennox outdoor air conditioning unit. Performed full system tune-up including cleaning condenser coils, checking refrigerant levels, testing electrical components and disconnect box, inspecting fan motor operation, and verifying proper airflow through louvers. Unit photographed and confirmed to be in operational condition with no immediate repairs required.
Responded to water leak under kitchen sink in historic 1924 home where leak had been present for approximately one week. Inspected P-trap assembly and drainage configuration beneath sink, replaced deteriorated PVC trap components, and verified proper seal connections to eliminate active leak. Confirmed no water intrusion in surrounding areas and tested system for proper drainage function.
Performed furnace inspection and documented existing equipment condition. Observed significant corrosion on gas supply piping and general wear on internal components including gas valve assembly, electrical connections, and wiring harnesses. Photographed corroded horizontal gas line, control wiring, and mechanical components showing age-related deterioration for customer records and future service reference.
Completed comprehensive Gold AC inspection on 6-year-old residential air conditioning system with air handler located in utility/back of house area. Performed full system evaluation including electrical component inspection, verified capacitor connections and contactor operation, checked all wiring terminations for proper connections and secure mounting. Inspected disconnect switch operation, confirmed proper electrical supply to unit, and examined blower motor assembly. Verified condensate drain line routing and functionality. All electrical components including capacitor, contactor, and control wiring found in good operational condition with proper connections. System operating as designed with no deficiencies noted during inspection.
Completed comprehensive tune-up and safety inspection on basement-located furnace, hot water tank, humidifier, and thermostat system. Performed combustion analysis using digital analyzer, recording CO2 levels at 8.4%, oxygen at 20.9%, with zero carbon monoxide detected and stack temperature at 98.9°F. All equipment found operating within normal parameters with no deficiencies noted.
# Plumbing Service Report Completed stack repair service in residential property. Replaced and reconfigured white PVC drain stack assembly in basement utility area, including multiple fittings and curved sections to ensure proper drainage flow. Connected flexible corrugated drain hose to new stack system and verified all connections were secure and leak-free. Work performed in area with existing PEX water lines and electrical infrastructure. All plumbing work completed to code specifications and system tested for proper operation.
Responded to emergency service call for a main drain backup affecting the toilet and shower. Performed temporary drain cleaning to restore functionality of plumbing fixtures until the scheduled stack repair on Monday. Identified significant buildup and residue in the drain system that will require the more comprehensive stack repair as previously arranged.
Responded to service call for main stack backup in unfinished basement. Utilized heavy-duty drain cleaning equipment to clear obstruction in the main vertical drainage pipe. Successfully restored proper flow in the plumbing system, eliminating backup issues.
Responded to emergency no-heat call for 4-year-old furnace. Diagnostic inspection revealed faulty flame sensor preventing ignition sequence completion. Cleaned oxidation from flame sensor, tested system through multiple heating cycles, and confirmed proper operation with normal flame signal readings.