Clinton Township is the most populated township in Michigan, and it has the most parks of any city or township in Macomb County, MI. Perhaps most notably is the multi-million dollar George George Park which features 30 acres of playgrounds, walking paths and a picnic pavilion. With all that land to roam, who has time to worry about seasonal heating and cooling? The HVAC experts at FLAME are the best choice for emergency repairs and appliance installation for Clinton Township.
During the summertime, Clinton Township hosts the Gratiot Cruise. The cruise features a parade of classic cars and is a free public event for friends and families, from Macomb County and beyond. With average summer temperatures reaching 82°F, make sure your house is cool with a high-efficiency air conditioner installed by our FLAME experts.
FLAME can also help you prepare your home for winter. The average temperature of Clinton Township winters can get as low as 15°F. Make sure your home is warm enough by calling a FLAME expert today for an in-home inspection, and, if you need service, FLAME offers our Clinton Township customers nothing but the highest-quality work.
Why choose FLAME for your Clinton Township heating and cooling needs?
Because FLAME does high-quality HVAC work and install only the most reliable Bryant® products, and it’s all backed by a 100% satisfaction guarantee.
Call FLAME today, at (586) 217-2512, or sign up online, and we’ll call you!
Recent Jobs and Reviews in Clinton Township , MI
Job Locations and Reviews
Conducted comprehensive site evaluation for high-efficiency HVAC system replacement. Assessed existing outdoor condenser unit with circular radial ventilation pattern, documented current electrical infrastructure including multiple meter housings and junction boxes mounted on exterior brick wall, and photographed refrigerant line routing and electrical disconnect components. Evaluated equipment placement, existing river rock landscaping base, and electrical service configuration to develop full system replacement estimate specifications.
Completed Gold AC Inspection on a 5-year-old residential air conditioning system with outdoor condenser unit and basement-located air handler. Performed comprehensive multi-point inspection including visual assessment of outdoor unit installation, electrical connections, refrigerant lines, and PVC condensate drainage system. All equipment found operating properly with no immediate service needs identified at time of inspection.
Completed comprehensive Gold AC Inspection on 10+ year old basement-located air handler system. Performed full multi-point inspection including refrigerant pressure checks, electrical connections, condensate drain verification, air filter assessment, and blower motor operation. All components found operating within manufacturer specifications with no immediate service needs identified at time of inspection.
Responded to service call for complete system failure affecting both heating and cooling control. Basement furnace (approximately 3 years old) and smart thermostat were non-operational, leaving entire residence without HVAC control. Performed diagnostic assessment and documented existing outdoor condensing unit and electrical metering configuration. Provided comprehensive replacement estimate for failed equipment to restore full system functionality.
Completed new air conditioning system installation estimate for residence with no existing A/C unit. Assessed electrical infrastructure at exterior meter location on brick wall, including weatherproof meter enclosure, conduit routing, and secondary junction box with existing wiring connections. Evaluated interior thermostat location with Honeywell digital control currently managing emergency heat functions. Provided comprehensive estimate for complete outdoor condensing unit installation, including electrical requirements, proper placement considerations, and system specifications suitable for the property's configuration.
Responded to no cooling complaint with complete system failure affecting both air conditioning and heating control. Upon arrival, found furnace and smart thermostat completely non-functional with no power to either unit. Performed diagnostic troubleshooting on 3-year-old furnace system located in basement. Identified failed TR40R dual element time delay fuse (40A 250V) in outdoor condensing unit disconnect as root cause of system failure. Inspected electrical control panel, capacitors, and circuit board for additional damage or failure points. Removed defective Tri-onic Smart SPOT fuse and replaced with new component, restoring power to system. Verified proper operation of furnace control board, thermostat communication, and air conditioning functionality. Tested all electrical connections and confirmed system restored to full operation. Coordinated with field supervisor per service protocol to review troubleshooting procedures and findings due to recurring service history. System retu
Responded to no cooling call on 15-year-old outdoor central air conditioning unit. Upon arrival, found severely deteriorated wiring with exposed copper conductors showing oxidation and corrosion, compromising electrical connections to the compressor. Documented the unsafe electrical condition and explained that the system required immediate replacement due to age and electrical failure presenting safety hazards.
Completed routine air conditioning maintenance inspection and tune-up on a 1-year-old system with outdoor condenser unit located in exterior service area and basement components. Performed comprehensive system evaluation including refrigerant charge assessment, where low refrigerant levels were identified and documented. Inspected condenser unit exterior condition, refrigerant line connections, electrical conduit routing, and proper mounting on concrete pad. Evaluated White-Rodgers programmable thermostat operation and settings for optimal performance. Documented system specifications and current operating parameters with photographic evidence. Provided full system estimate for necessary repairs and refrigerant recharge to restore unit to manufacturer specifications and ensure efficient cooling operation.
# Gold AC Inspection - HVAC Maintenance Completed comprehensive air conditioning tune-up and inspection under plan membership. Performed thorough examination of outdoor condensing unit, including evaluation of refrigerant lines, electrical connections, and overall system condition. ## Inspection Findings Outdoor unit exhibited moderate weathering consistent with age and environmental exposure. Copper refrigerant lines showed surface oxidation and corrosion typical of older systems. Significant debris accumulation observed within unit cabinet, including leaves, dirt, and spider webs around refrigerant line connections and internal components. Black insulation on refrigerant lines displayed deterioration and displacement in multiple areas. Unit exterior showed substantial staining and discoloration on side panel, indicating possible water intrusion or biological growth. Concrete pad displayed heavy algae and moss growth, suggesting inadequate drainage or moisture retention. Equipment
Responded to no cooling complaint on residential air conditioning system. Upon inspection, found condenser coil heavily obstructed with cottonwood seed debris and organic material, restricting airflow through the aluminum fins. Cleaned and cleared all foreign material from condenser coil using appropriate methods to restore proper airflow. Verified fan operation and unit functionality after cleaning. System restored to normal cooling operation.
Completed installation of 2-ton Bryant air conditioning system with matching evaporator coil on left side of residence. Mounted condenser unit on composite pad against exterior brick wall, established proper electrical connections via junction boxes, and installed condensate drain line with PVC piping. Indoor air handler positioned in utility room with all refrigerant lines connected, ductwork attached, and system tested for proper operation and reconnection to existing infrastructure.
Completed installation of 2.5-ton air conditioning unit with matching evaporator coil at rear location of mobile home structure. Successfully connected all refrigerant lines, electrical connections, and ductwork components including flexible boot attachment to main supply trunk. Unit utilizes A2L safety group flammable refrigerant with all required warning labels properly affixed to exterior cabinet. Mechanical permit requested and system reconnected per specifications.
Completed heating maintenance tune-up on Luxaire furnace system. Performed comprehensive system inspection including thermostat operation verification, burner assembly examination, heat exchanger inspection, blower motor assessment, and air filter evaluation. System tested and confirmed operating properly with all components functioning within normal parameters.
Completed comprehensive Gold AC Tune-Up on 1-year-old residential air conditioning system with outdoor condenser unit located in backyard. Performed full preventive maintenance inspection including checking refrigerant levels, testing electrical connections, cleaning condenser coils, inspecting fan operation and guard assembly, verifying proper airflow through louvered panels, and confirming all manufacturer specifications and safety labels are intact. Unit operating within normal parameters with no deficiencies noted; system covered under active service plan and in excellent condition for age.
Responded to no cooling complaint on 7-year-old central air conditioning system. Performed diagnostic evaluation of outdoor unit and indoor thermostat set at 77°F. Assessed system components, measured equipment clearances, and inspected refrigerant lines showing signs of age. Provided replacement estimate for complete HVAC system due to unit age and cooling performance issues.
Responded to no cooling complaint on 7-year-old central air conditioning system. Upon arrival, confirmed unit was running but not producing adequate cooling throughout the home. Performed comprehensive system diagnostic including refrigerant pressure check, electrical component testing, and airflow assessment. Inspected outdoor condenser unit located in backyard and indoor air handler serving 3-bedroom residence. Identified low refrigerant charge and traced to leak in refrigerant line. Provided customer with repair options and recommendations for leak repair and system recharge to restore proper cooling capacity.
Performed comprehensive tune-up on 6-year-old gas furnace located in basement. Inspected burner assembly with all five burners firing evenly with proper blue flame characteristics, checked gas valve operation and connections, verified all electrical components and wiring connections, and examined blower motor assembly. All components found operating within normal parameters with no deficiencies noted.
Completed comprehensive Gold AC Inspection on a 5-year-old residential air conditioning system with outdoor condenser unit and basement-located air handler. Performed full system evaluation including visual inspection of condenser unit mounted on exterior pad against brick wall, verified proper refrigerant line connections and electrical disconnect box functionality, and inspected indoor heating and cooling equipment. System found to be operational with no immediate service needs identified at time of inspection.
Completed Gold AC Inspection on 3-year-old residential air conditioning system. Performed comprehensive evaluation of outdoor condensing unit and basement-located air handler/coil assembly. System operating properly at time of inspection with no immediate service needs identified.
Responded to service call for Rheem tankless water heater (model EZOH200DVLKL2) displaying error code 99 with blinking display and no hot water delivery. Upon inspection, diagnosed system malfunction related to temperature sensor or control board issue causing false temperature reading. Performed troubleshooting procedures, reset unit controls, verified proper operation of circulator pump and plumbing connections, and restored hot water flow to system.