Clinton Township is the most populated township in Michigan, and it has the most parks of any city or township in Macomb County, MI. Perhaps most notably is the multi-million dollar George George Park which features 30 acres of playgrounds, walking paths and a picnic pavilion. With all that land to roam, who has time to worry about seasonal heating and cooling? The HVAC experts at FLAME are the best choice for emergency repairs and appliance installation for Clinton Township.
During the summertime, Clinton Township hosts the Gratiot Cruise. The cruise features a parade of classic cars and is a free public event for friends and families, from Macomb County and beyond. With average summer temperatures reaching 82°F, make sure your house is cool with a high-efficiency air conditioner installed by our FLAME experts.
FLAME can also help you prepare your home for winter. The average temperature of Clinton Township winters can get as low as 15°F. Make sure your home is warm enough by calling a FLAME expert today for an in-home inspection, and, if you need service, FLAME offers our Clinton Township customers nothing but the highest-quality work.
Why choose FLAME for your Clinton Township heating and cooling needs?
Because FLAME does high-quality HVAC work and install only the most reliable Bryant® products, and it’s all backed by a 100% satisfaction guarantee.
Call FLAME today, at (586) 217-2512, or sign up online, and we’ll call you!
Recent Jobs and Reviews in Clinton Township , MI
Job Locations and Reviews
Responded to no cooling complaint on 3-year-old residential air conditioning system with outdoor condenser unit located in backyard. Upon arrival, performed visual inspection of exterior condenser unit and verified proper electrical service to equipment. Conducted diagnostic evaluation to identify cause of cooling failure and assessed overall system operation and component functionality.
Performed estimate for complete air conditioning system replacement at residential property. Existing AC unit is approximately 20 years old and has reached end of serviceable life, located on exterior side of house. Inspected indoor air handler/furnace unit in basement mechanical room, noting copper refrigerant lines, metal ductwork connections with flexible and rigid sections, and standard PVC condensate drainage. Documented current system configuration including electrical connections and mounting arrangement. Photographed existing equipment to assess replacement requirements and provide visual reference for proposal. Recommended full system replacement due to age and efficiency considerations.
Completed callback to install low-profile exhaust vent kit on exterior brick wall for improved aesthetics and customer satisfaction. Inspected condensate pump system for reported water leak concerns, verified proper drainage operation, and confirmed secure mounting of discharge piping along exterior wall structure. All components functioning properly with no active leaks detected at time of inspection.
Completed full HVAC system installation including 90,000 BTU furnace and 4-ton air conditioning unit with rear discharge configuration. Installed humidifier, liner, and condensate pump, performed all necessary ductwork connections, and reconnected existing equipment. Obtained mechanical permit, completed remeasure verification, and documented AHRI certificate number for utility rebate processing.
Completed full HVAC system installation in residential basement including 70,000 BTU Lennox furnace, 3-ton air conditioning system, whole-home humidifier, and 50-gallon water heater. All equipment positioned on left side of utility room with proper clearances for service access. Installed white PVC venting for high-efficiency furnace routed through ceiling joists, connected humidifier to HVAC system with appropriate supply lines, and integrated all electrical connections per code requirements. Reconnected existing ductwork to new furnace unit and verified proper airflow throughout system. Commissioned AC system using digital manifold gauges, confirmed refrigerant pressures (108.0 psi low side, 207.4 psi high side), verified superheat at 100.0°F and subcooling parameters within manufacturer specifications. Water heater installed with code-compliant venting and plumbing connections. Mechanical permit secured and all work performed to local building code standards. System tested and opera
Responded to persistent toilet malfunction on Kohler K160 unit that continued after previous repair attempt. Senior plumber reassessed the system and removed the existing fill valve, flapper, and supply line. Installed new replacement components and conducted thorough testing to verify proper function and water flow. Coordinated with municipal water department to schedule main water shut-off for the following morning to complete necessary repairs. All new parts installed with warranty coverage on both parts and labor.
Performed comprehensive air conditioning maintenance and inspection on residential cooling system. Evaluated humidifier control settings and verified proper humidity level configuration based on outdoor temperature parameters. Documented existing water heater installation and associated plumbing connections during system assessment, noting equipment conditions and component functionality for maintenance records.
Completed comprehensive Gold AC inspection on 10+ year old Lennox air conditioning system with air handler located in kitchen area. Performed full system evaluation including outdoor condenser unit inspection, verified proper operation of all components, checked refrigerant levels and airflow, and confirmed MERV 11 filter (16x25x4) was properly installed with correct airflow direction. System found to be operating within normal parameters with no immediate service needs identified.
Responded to a clogged basement toilet drain caused by a scrubby that was accidentally dropped and flushed. Assessed the situation and determined the toilet would need to be pulled to access and remove the obstruction from the drain line. Located and inspected the basement plumbing system, including the toilet drain connection and cleanout access points.
Conducted on-site assessment for complete HVAC system replacement at owner-occupied residence. Evaluated existing basement-mounted forced air furnace and outdoor condensing unit, both showing significant age-related deterioration including rust, discoloration, and accumulated wear. Documented current system configuration including ductwork layout, electrical connections, and equipment placement between structures. Prepared comprehensive replacement estimate for full heating and cooling system installation.
Completed comprehensive Gold AC Inspection on a one-year-old Lennox outdoor condensing unit located on residential property. Performed full system evaluation including visual inspection of condenser cabinet, louvered panels, fan assembly, and refrigerant lines, confirming unit is in excellent operational condition with no visible damage, corrosion, or maintenance concerns. Air handler/coil located in basement was assessed as part of complete system check, with all components functioning properly and meeting manufacturer specifications.
Provided comprehensive estimate for complete HVAC system replacement including air conditioning unit and natural gas furnace for 25-year-old equipment located in basement. The existing Lennox outdoor condensing unit is non-operational and requires replacement, while the furnace replacement is being quoted proactively due to age. Assessed current installation including outdoor unit positioning on concrete pad with gravel base against exterior brick wall, evaluated electrical service connections and metering configuration, and documented equipment specifications to provide accurate replacement options for both heating and cooling systems.
Completed comprehensive Gold AC inspection on 5-year-old residential air conditioning system with air handler located in basement. Performed multi-point inspection of outdoor condenser unit including fan motor operation, electrical connections, refrigerant lines, and cabinet condition. Verified proper operation of all system components, inspected auxiliary equipment including accumulator and electrical disconnect, and confirmed condenser area was clear of debris. System found to be operating within normal parameters with all components functioning properly.
Performed comprehensive assessment of 15-year-old air conditioning system located in basement that was blowing air but not producing cold air, affecting entire home. Documented existing equipment condition through photographic evidence showing aged HVAC unit with visible wear, dust accumulation, and deteriorating components including heat exchanger with metallic fins. Provided replacement estimate for complete system due to age and failure to cool, with customer enrolling in maintenance plan for two pieces of equipment.
Responded to callback for complete system failure affecting both heating and cooling control. Upon arrival, found furnace and smart thermostat completely non-responsive with no power to either unit. Traced electrical circuit from basement furnace location through thermostat wiring and identified loss of power at furnace control board. Inspected 3-year-old furnace unit for tripped breakers, blown fuses, or transformer failure. Restored power to system by addressing electrical fault at furnace, which re-established communication between thermostat and HVAC equipment. Verified proper operation of both air conditioning and heating functions. Confirmed thermostat regained full control capability and tested system cycling. Issue resolved with whole-house climate control restored to normal operation.
Conducted on-site evaluation for boiler replacement in residential basement mechanical room. Existing 15-year-old boiler system assessed, including current hydronic heating configuration with copper piping network, expansion tank, and associated plumbing components. Documented current installation layout featuring wall-mounted boiler unit with PVC exhaust/intake venting, multiple zone valves, pressure relief components, and connection points throughout the distribution system. Photographed existing equipment specifications, piping arrangements, and mechanical room conditions to prepare comprehensive replacement estimate for new boiler installation.
Provided comprehensive replacement estimate for non-operational residential air conditioning system over 10 years old, including outdoor condenser unit and indoor natural gas furnace located in utility room. Assessed existing equipment configuration, photographed current installation showing outdoor condenser with refrigerant line routing and indoor furnace with blower assembly and ductwork connections. Reviewed system specifications and discussed replacement options to restore cooling and heating functionality for the home.
Performed comprehensive boiler inspection in basement mechanical room for new homeowner. Conducted visual assessment of boiler system, expansion tank, venting components, and associated plumbing connections. Verified proper operation of heating equipment, examined ductwork connections, inspected gas piping and safety controls, and documented system condition with photographs for homeowner records.
Responded to no cooling call on 7-year-old Bryant system. Upon arrival, found system completely inoperative with no power to indoor or outdoor units. Discovered failed 3-amp fuse on low-voltage control circuit in air handler. Replaced defective fuse and restored power to system. Verified proper operation of thermostat communication, contactor engagement, and compressor startup. Tested system through complete cooling cycle with normal temperature differential across evaporator coil and proper outdoor unit operation.
Responded to no cooling complaint on 15-year-old air conditioning system affecting entire home. Performed diagnostic testing on outdoor unit using digital multimeter to check electrical components including capacitor, contactor, and associated wiring connections. Found system only circulating air without cooling capability. Identified failed component preventing compressor operation and explained repair options for aging equipment to customer, who elected to enroll in maintenance plan for multiple systems.