
Keep your Farmington Hills home’s HVAC system up and running all year round, especially during the winter. At FLAME Heating, Cooling, Plumbing & Electrical, we aim to provide you with the expert heating and cooling solutions you deserve.
If you’re looking for reliable HVAC services in Farmington Hills, schedule a service with a technician or call 586-271-8813.
Reliable Furnace Installation and Repair
A furnace provides steady heat and is a convenient option. You can also choose an electric or gas furnace, whichever suits your needs. Whether you need furnace installation or repair in Farmington Hills, Michigan, our team will handle any service with attention to detail.
Furnace Installation
We’ll work with you to determine the right furnace type for your home and will install and connect it. Our thorough installation will prepare your household for the cold winters.
Furnace Maintenance and Repair
Furnace repair in Farmington Hills, Michigan, is an important service, and our team is ready to help with any issue. Whether your system is getting old or you’re noticing strange sounds or odors, we’ll identify the problem and apply the best solution.
We also install other types of heaters, including:
- Heat pumps
- Ductless mini-splits
- Packaged units
- Boilers and combination boilers
AC Repair and Installation Services
A summer’s day outside can be great, but only if you can return to a cool home. We specialize in virtually any type of AC system, providing comprehensive services you can count on. Let the team at FLAME Heating, Cooling, Plumbing & Electrical take care of your AC needs, including:
- AC installation: Our technicians will install your AC unit so it works efficiently and effectively. From central to ductless mini-split systems, we offer expert installation, readying you for the warmer months.
- AC repair and maintenance: If your air conditioner uses more energy than usual, is noisy, or isn’t cooling your home, it might be time for a repair. Rest assured, we’ll give the unit a new lease on life with comprehensive, targeted repairs.
See Why FLAME Heating, Cooling, Plumbing & Electrical Is Different
Whether you need a heater or AC repair in Farmington Hills, Michigan, you can trust our dedication to quality. We’ve been serving the community of Farmington Hills for over 75 years and continue to deliver exceptional services. When you choose us for your heating and cooling needs, you can enjoy:
- Prompt response times: We understand the urgency of an HVAC repair or installation and start the project swiftly.
- HVAC service experts: We specialize in all things HVAC, from heating to cooling and air quality. Our technicians are expertly trained and have the skills and experience to handle all your HVAC needs.
- Full-service company: Our comprehensive services include HVAC, plumbing, and electrical services.
- Financing options: Home care for HVAC, plumbing, and electrical needs isn’t cheap. That’s why we provide financing solutions and are upfront with our pricing to ensure we’re within your budget before you use our services. We even offer extensive discounts you can take advantage of immediately.
Schedule With FLAME Today
Our licensed and insured HVAC, plumbing, and electrical technicians at FLAME Heating, Cooling, Plumbing & Electrical have proudly served the Farmington Hills area since 1949. We strive to do the best job and treat your home and office as we would our own.
Contact FLAME for HVAC, plumbing, and electrical services by calling 586-271-8813.
Recent Jobs and Reviews in Farmington Hills , MI
Farmington Hills, MI at a glance
Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Farmington Hills, MI between July 2026 and August 2026.
The most recent job was on August 21, 2026.
Job Locations and Reviews
Responded to service call for leaking kitchen faucet. Inspected brushed nickel pull-down faucet mounted on granite countertop with stainless steel undermount sink. Identified source of leak and performed necessary repairs to stop water dripping. Tested faucet operation to ensure proper function and confirmed no further leakage present.
Completed comprehensive tune-up and safety inspection on 25-year-old furnace system located in basement. Performed electrical diagnostics using digital multimeter to verify proper voltage and amperage readings across control board and system components. Inspection included evaluation of humidifier operation, thermostat functionality, hot water tank condition, blower assembly, wiring connections, and all safety controls to ensure system is operating within manufacturer specifications.
Responded to no cooling call on residential split system with 1-year-old outdoor condenser and 2-year-old attic air handler. Upon arrival, verified thermostat was calling for cooling with display showing 73°F setpoint. Inspected outdoor unit located in backyard on concrete pad and confirmed unit was not operating. Checked electrical connections at disconnect and verified 240V power supply present at condenser. Tested contactor and found failed contacts preventing compressor and condenser fan operation. Replaced defective contactor with OEM equivalent part. Cycled system through multiple cooling cycles to verify proper operation of compressor, condenser fan motor, and overall system performance. Confirmed adequate airflow at indoor registers and proper temperature split across evaporator coil. System restored to normal cooling operation with all components functioning as designed.
Completed comprehensive whole home plumbing inspection with emphasis on kitchen area in preparation for upcoming remodeling project. Inspected and documented sump pump system in basement, including PVC discharge piping, check valve configuration, and pump pit condition; noted operational status and water accumulation levels. Thoroughly examined under-sink plumbing infrastructure in kitchen area, evaluating PVC drainage system, supply line connections, and pipe joint integrity. Identified deteriorated wall conditions behind cabinetry with significant paint and plaster damage requiring attention during remodel. Documented all findings with photographic evidence for customer reference and contractor coordination.
Responded to service call for RTU blowing warm air on rooftop location. Accessed equipment using 24-foot ladder and performed diagnostic assessment of unit experiencing cooling malfunction. Completed filter replacement service on five total RTU units, installing new pleated air filters with proper dimensions (18x20x2 and 16x20x2) to restore airflow efficiency. Verified filter installation in air handler compartments and documented condition of HVAC systems post-service.
Completed comprehensive Gold AC inspection on 3-year-old air conditioning system with outdoor condenser unit located on exterior pad. Performed multi-point inspection including electrical connections, refrigerant levels, condensate drainage, airflow verification, and overall system performance testing. Unit found to be operating within normal parameters with no immediate service needs identified; confirmed proper installation on base pad with adequate clearance and verified all safety controls functioning correctly.
Performed comprehensive maintenance service on wall-mounted Rheem tankless water heater for new property owner. Conducted complete system flush to remove mineral buildup and sediment, inspected all plumbing connections including copper supply lines and brass fittings with isolation valves, verified proper operation of unit and all components, and confirmed system temperature output at 129°F. All components found to be in good working order with no leaks or operational issues detected.
Completed comprehensive inspection of single rooftop AC unit accessed via ladder. Performed visual assessment of RTU components, checked refrigerant lines, electrical connections, and mechanical systems per owner-required certification standards. Documented equipment condition with interior crawl space and exterior rooftop photographs showing unit location, surrounding infrastructure, and accessible service areas. All inspection criteria met and unit found operational within normal parameters.
Completed comprehensive Gold AC inspection on 12-year-old residential cooling system with outdoor condenser unit and basement-located air handler. Performed multi-point inspection including visual examination of condenser unit, verified proper airflow through ventilation fins, checked unit specifications and safety labels for compliance, and documented equipment condition through photographic records. System operational at time of inspection with condenser unit showing normal wear consistent with age, positioned in well-maintained backyard landscape with adequate clearance from surrounding vegetation for proper air circulation.
Responded to service call for central air conditioning system with no cooling capability. Upon inspection, evaluated existing HVAC equipment in mechanical room and exterior condenser unit at multi-unit building. Assessed system components including ductwork, venting, and outdoor condensing unit. Determined system required full replacement rather than repair. Provided estimate for complete HVAC system replacement including new air handler, condenser unit, refrigerant lines, and associated components necessary to restore cooling functionality to the property.
Completed comprehensive Gold Furnace Inspection on a one-year-old forced air heating system located in basement. Performed thorough examination of all mechanical and electrical components including gas valve assembly, ignition system, blower motor, and control board wiring connections. Inspected air filter condition and verified proper installation in filter compartment. All components found to be operating within normal parameters with secure wiring bundles and intact connections throughout system. Unit confirmed to be functioning properly with no deficiencies noted during inspection.
Completed comprehensive tune-up on 10+ year old residential air conditioning system with outdoor condenser unit and basement-located air handler. Performed standard maintenance protocol including inspection of condenser coils, cleaning of debris from protective mesh screen, verification of refrigerant levels, electrical component testing, and system operational check. Unit confirmed working properly with all components functioning within normal parameters.
Responded to no-cooling complaint on residential central air conditioning system. Upon arrival, found outdoor condenser unit with significant weathering and age-related deterioration. Inspected dual condenser setup with primary unit showing extensive rust and oxidation on copper-colored top grille, indicating prolonged exposure to elements. Evaluated electrical connections, refrigerant lines, and overall system operation. Documented equipment condition showing compromised components and aging infrastructure requiring attention to restore cooling capacity.
Responded to no-cooling call on 1-year-old attic-mounted air conditioning system experiencing complete failure, identified as repeat issue from previous service. Diagnosed faulty thermostatic expansion valve (TXV) preventing refrigerant flow and system operation. Ordered replacement TXV-3T-454 component from shop inventory for R410A system rated at 670 psig MWP. Documented existing copper refrigerant line configuration, valve assembly, and system components via photos for warranty documentation and future reference.
Completed comprehensive Gold AC Inspection on 10+ year old residential air conditioning system with outdoor condensing unit and basement-located air handler. Performed electrical diagnostics using digital multimeter to verify proper amperage draw and voltage levels at the outdoor unit. Inspected evaporator coil assembly through access grille, noting presence of condensation on coil fins indicating normal operation. System confirmed operational with no deficiencies identified during inspection. All components functioning within normal parameters.
Completed comprehensive gold-level preventive maintenance inspection on recently installed Lennox air conditioning system. Unit had not yet been activated for the season. Performed full system evaluation including exterior condenser inspection, verified proper installation on rubber isolation pad with adequate drainage, confirmed electrical connections, and assessed Honeywell HumidiPRO thermostat operation currently set to system off mode at 68 degrees. All components found in excellent condition with no deficiencies noted on this new installation.
Completed comprehensive Gold AC inspection on 3-year-old residential air conditioning system. Unit confirmed operational at time of service. Performed full system evaluation including inspection of outdoor condensate drain line and drainage components, verifying proper flow and secure connections. Reviewed and documented Aprilaire humidistat settings and operation, noting seasonal adjustment recommendations for optimal humidity control. All accessible components photographed for service records. System operating within normal parameters with no immediate repairs required.
Responded to service call for inadequate cooling with unit running continuously and unable to reach setpoint temperature. Evaluated two outdoor condenser units located at rear of residence—one approximately 7 years old and one approximately 15 years old—both mounted on concrete pads against exterior brick wall. Performed comprehensive system assessment and provided replacement estimate for aging equipment that is unable to maintain desired indoor temperatures. Discussed maintenance program options to extend equipment longevity and optimize system performance.
Completed installation of 5-ton Lennox air conditioning system with matching evaporator coil at rear of residence. Installed outdoor condenser unit on rubber pad with gravel base, positioned adjacent to brick exterior wall with proper clearances. Connected refrigerant lines with service ports, completed electrical connections, and installed white PVC condensate drainage. Indoor air handler installed in utility room with beige tile flooring, equipped with condensate pump for proper drainage management. Performed system flush and refrigerant line connections. All mechanical work completed per permit requirements with reconnection of existing electrical components.
Responded to service call for noisy central air conditioning unit. Upon inspection, diagnosed and addressed excessive noise issue originating from the HVAC system. System was found operational with heating and cooling functions intact. Performed necessary repairs to eliminate noise disturbance, tested unit operation, and verified quiet performance upon completion.