Keep your Farmington Hills home’s HVAC system up and running all year round, especially during the winter. At FLAME Heating, Cooling, Plumbing & Electrical, we aim to provide you with the expert heating and cooling solutions you deserve.
If you’re looking for reliable HVAC services in Farmington Hills, schedule a service with a technician or call 586-271-8813.
Reliable Furnace Installation and Repair
A furnace provides steady heat and is a convenient option. You can also choose an electric or gas furnace, whichever suits your needs. Whether you need furnace installation or repair in Farmington Hills, Michigan, our team will handle any service with attention to detail.
Furnace Installation
We’ll work with you to determine the right furnace type for your home and will install and connect it. Our thorough installation will prepare your household for the cold winters.
Furnace Maintenance and Repair
Furnace repair in Farmington Hills, Michigan, is an important service, and our team is ready to help with any issue. Whether your system is getting old or you’re noticing strange sounds or odors, we’ll identify the problem and apply the best solution.
We also install other types of heaters, including:
- Heat pumps
- Ductless mini-splits
- Packaged units
- Boilers and combination boilers
AC Repair and Installation Services
A summer’s day outside can be great, but only if you can return to a cool home. We specialize in virtually any type of AC system, providing comprehensive services you can count on. Let the team at FLAME Heating, Cooling, Plumbing & Electrical take care of your AC needs, including:
- AC installation: Our technicians will install your AC unit so it works efficiently and effectively. From central to ductless mini-split systems, we offer expert installation, readying you for the warmer months.
- AC repair and maintenance: If your air conditioner uses more energy than usual, is noisy, or isn’t cooling your home, it might be time for a repair. Rest assured, we’ll give the unit a new lease on life with comprehensive, targeted repairs.
See Why FLAME Heating, Cooling, Plumbing & Electrical Is Different
Whether you need a heater or AC repair in Farmington Hills, Michigan, you can trust our dedication to quality. We’ve been serving the community of Farmington Hills for over 75 years and continue to deliver exceptional services. When you choose us for your heating and cooling needs, you can enjoy:
- Prompt response times: We understand the urgency of an HVAC repair or installation and start the project swiftly.
- HVAC service experts: We specialize in all things HVAC, from heating to cooling and air quality. Our technicians are expertly trained and have the skills and experience to handle all your HVAC needs.
- Full-service company: Our comprehensive services include HVAC, plumbing, and electrical services.
- Financing options: Home care for HVAC, plumbing, and electrical needs isn’t cheap. That’s why we provide financing solutions and are upfront with our pricing to ensure we’re within your budget before you use our services. We even offer extensive discounts you can take advantage of immediately.
Schedule With FLAME Today
Our licensed and insured HVAC, plumbing, and electrical technicians at FLAME Heating, Cooling, Plumbing & Electrical have proudly served the Farmington Hills area since 1949. We strive to do the best job and treat your home and office as we would our own.
Contact FLAME for HVAC, plumbing, and electrical services by calling 586-271-8813.
Recent Jobs and Reviews in Farmington Hills , MI
Farmington Hills, MI at a glance
Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Farmington Hills, MI in July 2026.
The most recent job was on July 24, 2026.
Job Locations and Reviews
Completed comprehensive Gold AC Inspection on residential split system with outdoor condenser unit located on concrete pad and indoor air handler in basement. Performed full system evaluation including visual inspection of condenser coil, fan motor assembly, refrigerant line connections, electrical components, and condensate drainage system. Unit showed normal weathering consistent with outdoor exposure, all components operational with no immediate service needs identified at time of inspection.
Performed comprehensive AC tune-up on residential split system including inspection of air handler components in basement and outdoor condensing unit. Verified refrigerant line connections, electrical wiring integrity, and condensate drain functionality. All system components operating within normal parameters; no deficiencies noted during preventive maintenance inspection.
Completed comprehensive estimate for replacement of 10+ year old residential air conditioning system. Evaluated existing Bryant condensing unit located on exterior gravel pad with air handler and evaporator coil situated in basement. Documented current system configuration including electrical service, refrigerant line routing, and condenser placement on side of residence. Photographed existing equipment and installation area to assess replacement requirements. Advised property owner on importance of maintaining clear area around outdoor unit, free from debris and animal waste. Provided recommendations for complete AC system replacement due to age of equipment.
Performed comprehensive cooling season tune-up on 8-year-old Daikin air conditioning system. Conducted full operational assessment including refrigerant levels, electrical connections, compressor function, and airflow verification. Noted outdoor condenser unit sitting off-level on concrete pad; unit remains stable but recommend monitoring for future leveling needs. All system parameters operating within manufacturer specifications. Cleared vegetation and debris from around unit perimeter to ensure proper airflow and drainage. System confirmed operational and ready for cooling season.
Completed comprehensive Gold AC inspection on 10+ year old HVAC system with air handler and coil located in basement. Performed thorough evaluation of all system components including condensate drainage lines, electrical connections, and equipment cabinet accessibility. Advised customer that condenser exterior area requires clearing of debris and animal waste to ensure proper airflow and system efficiency, and that weather conditions below 65 degrees or rain may necessitate rescheduling of future inspections for accurate performance assessment.
Responded to cooling complaint where system was unable to maintain setpoint and running continuously. Performed diagnostic evaluation on both outdoor units (7-year and 15-year models). Found severely restricted airflow on outdoor coil due to heavy accumulation of dirt, debris, and environmental contaminants blocking heat exchange fins. Electrical contactor showed significant dust buildup and signs of age-related wear. Documented equipment condition with photos showing extent of coil contamination and component deterioration. Completed check-with-office-on-work diagnostic assessment to provide recommendations for coil cleaning service and potential component replacement to restore proper system operation and cooling capacity.
Completed comprehensive Gold AC Inspection on 4-year-old residential HVAC system with air handler and coil located in basement. Performed multi-point inspection of furnace, air handler, Aprilaire humidifier, ductwork, condensate drainage system, and all associated components. All equipment found to be in normal operational condition with no visible defects, leaks, or safety concerns identified during inspection.
Completed comprehensive Gold AC inspection on a 1-year-old outdoor condensing unit. System is operational and in excellent condition with clean surfaces, no visible damage, rust, or deterioration noted. Verified proper airflow through louvered vents, inspected fan guard and condenser components, and documented unit condition with photos showing well-maintained equipment and proper installation against residential structure.
Conducted comprehensive assessment of attic-mounted air conditioning system experiencing no-cool condition. Evaluated existing HVAC infrastructure including ductwork, electrical components, and control board functionality to determine extent of repairs needed. Provided detailed estimate for complete system replacement due to age and condition of equipment requiring extensive rewiring and component upgrades.
Responded to homeowner report of gas leak in residential property. Upon arrival, conducted comprehensive visual inspection of gas piping system in mechanical room, identifying aging galvanized steel pipes with visible surface corrosion and multiple connection points requiring evaluation. Performed systematic pressure test on gas distribution lines to isolate and verify leak location. Inspected copper and galvanized pipe connections, fittings, and shut-off valves throughout the system, paying particular attention to corroded joints and T-fittings showing signs of deterioration. Tested all accessible gas line connections in utility area and adjacent spaces, including areas near water heater installation. System pressure test confirmed integrity of gas lines; no active leaks detected at time of inspection. Verified proper operation of existing shut-off valves. Advised homeowner that while no immediate leak was found during testing, the visible corrosion on aging galvanized pipes warrants
Responded to no cooling complaint on attic-mounted AC unit. Upon inspection, identified failed control board and improper wiring connections at the electrical panel. Documented existing wire routing and terminal connections with photographs showing yellow, white, orange, red, and green wires at the terminal block. Control board has been ordered and is expected to arrive Wednesday for installation. Will return to install replacement control board and correct wiring issues to restore cooling operation.
Completed annual backflow preventer testing on exterior-mounted copper assembly as required by municipal code. Retrieved certified testing kit from warehouse, performed full inspection and operational test of brass control valve and backflow device mounted on building exterior, verified all check valves and relief ports functioning within acceptable parameters, and documented system compliance with current cross-connection control standards.
Completed comprehensive Gold AC Inspection on a 5-year-old Bryant air conditioning system with indoor air handler located in basement. Performed full system evaluation including inspection of outdoor condenser unit, verified proper operation of all components, checked refrigerant levels and electrical connections, and documented Trane humidifier control settings. System found to be operating within normal parameters with all equipment functioning properly at time of inspection.
Completed Gold AC inspection on single residential unit with air handler located in basement. Performed comprehensive system evaluation including inspection of outdoor condensing unit, verified operational status of all components, and documented equipment condition through photographic records. Unit confirmed to be functioning properly at time of inspection.
Completed comprehensive Gold AC Inspection on residential air conditioning system with outdoor condenser unit positioned against exterior brick wall. Performed full system diagnostic including refrigerant level check, electrical component testing, condenser coil inspection, and airflow verification. Inspected air filter showing moderate dust accumulation and debris buildup in pleated material. Cleaned condenser unit exterior which exhibited typical outdoor exposure with accumulated leaves, twigs, and organic debris around base and cooling fins. Verified proper operation of condenser fan motor and compressor. Tested thermostat functionality and system cycling. All components operating within manufacturer specifications with no immediate service needs identified. Unit showing normal wear for age with adequate cooling performance maintained.
Responded to cooling complaint on 11-year-old AC system failing to reach thermostat setpoint of 74 degrees, with indoor temperature remaining at 77 degrees. Upon inspection, found outdoor condenser unit operational but with moderate airflow restriction due to significant debris accumulation, dirt buildup, and weathering on compressor section. Cleaned condenser coils and housing, removed environmental debris from unit, verified refrigerant lines and electrical connections showed age-appropriate wear with surface corrosion but remained functional, and restored proper airflow to system.
Installed new half-inch gas line with shutoff valve in basement with open ceiling to supply gas dryer on first floor near garage door adjacent to kitchen. Routed flexible gas line from existing gas supply, secured properly per code, and installed shutoff valve for appliance isolation. Verified all connections for proper seal and tested system for leaks with no issues detected.
Completed annual gold plan preventive maintenance on 10-year-old residential air conditioning system with outdoor condenser unit and basement air handler. Performed comprehensive inspection including electrical connections, refrigerant levels, condensate drain, air filter replacement, coil cleaning, and operational testing of all components. System operating within normal parameters with no deficiencies noted; unit confirmed ready for cooling season.
Completed comprehensive Gold AC Inspection and tune-up on an 11-year-old air conditioning system located at the rear of the property. Performed full preventive maintenance protocol including system performance evaluation, refrigerant level check, electrical component testing, condenser coil cleaning, and air filter inspection. Unit operating within normal parameters with no deficiencies noted at time of service.
Completed comprehensive Gold AC inspection on 10+ year old residential air conditioning system with basement-located air handler. Performed detailed evaluation of 123ANA036-C unit (S/N 2614E14715), a 3-ton R410A system rated at 208-230V. Conducted electrical diagnostics using digital multimeter to verify proper voltage and amperage readings, confirming system operating within manufacturer specifications. Inspected condenser unit exterior condition, verified nameplate data legibility, and documented equipment specifications. Unit currently operational with no immediate concerns identified. Captured photographic documentation of equipment nameplate and diagnostic measurements for service records.