Keep your Farmington Hills home’s HVAC system up and running all year round, especially during the winter. At FLAME Heating, Cooling, Plumbing & Electrical, we aim to provide you with the expert heating and cooling solutions you deserve.
If you’re looking for reliable HVAC services in Farmington Hills, schedule a service with a technician or call 586-271-8813.
Reliable Furnace Installation and Repair
A furnace provides steady heat and is a convenient option. You can also choose an electric or gas furnace, whichever suits your needs. Whether you need furnace installation or repair in Farmington Hills, Michigan, our team will handle any service with attention to detail.
Furnace Installation
We’ll work with you to determine the right furnace type for your home and will install and connect it. Our thorough installation will prepare your household for the cold winters.
Furnace Maintenance and Repair
Furnace repair in Farmington Hills, Michigan, is an important service, and our team is ready to help with any issue. Whether your system is getting old or you’re noticing strange sounds or odors, we’ll identify the problem and apply the best solution.
We also install other types of heaters, including:
- Heat pumps
- Ductless mini-splits
- Packaged units
- Boilers and combination boilers
AC Repair and Installation Services
A summer’s day outside can be great, but only if you can return to a cool home. We specialize in virtually any type of AC system, providing comprehensive services you can count on. Let the team at FLAME Heating, Cooling, Plumbing & Electrical take care of your AC needs, including:
- AC installation: Our technicians will install your AC unit so it works efficiently and effectively. From central to ductless mini-split systems, we offer expert installation, readying you for the warmer months.
- AC repair and maintenance: If your air conditioner uses more energy than usual, is noisy, or isn’t cooling your home, it might be time for a repair. Rest assured, we’ll give the unit a new lease on life with comprehensive, targeted repairs.
See Why FLAME Heating, Cooling, Plumbing & Electrical Is Different
Whether you need a heater or AC repair in Farmington Hills, Michigan, you can trust our dedication to quality. We’ve been serving the community of Farmington Hills for over 75 years and continue to deliver exceptional services. When you choose us for your heating and cooling needs, you can enjoy:
- Prompt response times: We understand the urgency of an HVAC repair or installation and start the project swiftly.
- HVAC service experts: We specialize in all things HVAC, from heating to cooling and air quality. Our technicians are expertly trained and have the skills and experience to handle all your HVAC needs.
- Full-service company: Our comprehensive services include HVAC, plumbing, and electrical services.
- Financing options: Home care for HVAC, plumbing, and electrical needs isn’t cheap. That’s why we provide financing solutions and are upfront with our pricing to ensure we’re within your budget before you use our services. We even offer extensive discounts you can take advantage of immediately.
Schedule With FLAME Today
Our licensed and insured HVAC, plumbing, and electrical technicians at FLAME Heating, Cooling, Plumbing & Electrical have proudly served the Farmington Hills area since 1949. We strive to do the best job and treat your home and office as we would our own.
Contact FLAME for HVAC, plumbing, and electrical services by calling 586-271-8813.
Recent Jobs and Reviews in Farmington Hills , MI
Job Locations and Reviews
Responded to persistent "dancing pipes" noise complaint in 1967-built home, occurring between laundry room and half bath on main floor for four years despite previously installed water hammer arresters. Performed diagnostic assessment of plumbing system, identifying inadequate pipe strapping as the source of vibration and noise. Strategically removed minimal sections of drywall to access affected pipe runs, installed additional pipe strapping and support brackets to secure loose copper supply lines, and verified elimination of noise through multiple fixture operation tests.
Completed installation of a 3.5-ton air conditioning unit with matching evaporator coil in the rear yard location. System was professionally mounted on brick exterior, all electrical connections and refrigerant lines were properly installed and secured with appropriate conduit and cable management, and unit was successfully reconnected and tested for proper operation.
Completed installation of flexible ductwork and HVAC modifications in commercial office space, including routing and securing flex duct to ensure proper airflow distribution. Installed new Emerson thermostat with necessary wiring and programming for climate control system operation. Verified all connections, tested system functionality, and confirmed proper temperature regulation throughout the workspace.
Completed installation of a 4-ton air conditioning system with matching evaporator coil in basement mechanical room, positioned on right side of existing utility area. Unit installed per manufacturer specifications using R-454B refrigerant, with all condensate lines, refrigerant lines, and ductwork connections completed. Electrical reconnection work noted as requiring licensed electrician for final power connection, and mechanical permit has been requested for inspection compliance.
Responded to water leak above basement laundry washtub in 60-year-old residence. Conducted thorough inspection of laundry room area to identify source of leak that had been active for 1-2 days. Examined plumbing connections beneath appliances, including braided stainless steel supply lines and shutoff valves. Inspected flexible hose connections and mounting hardware for signs of failure or deterioration. Documented conditions with photographs showing underside of appliances, water supply connections, and floor surfaces. Located compromised connection point at appliance supply line. Tightened loose fitting and verified all connections were secure. Tested system for proper operation and confirmed leak was resolved with no further water discharge observed.
Conducted comprehensive evaluation of 14-year-old residential air conditioning system experiencing multiple failure indicators. Identified active refrigerant leak, severely pitted contactor showing signs of electrical arcing, and compressor exhibiting abnormal noise during startup and shutdown cycles indicating internal mechanical wear. Documented existing Lennox air handler installation in basement with associated ductwork and drainage systems. Prepared replacement estimate for complete HVAC system upgrade, noting that outdoor condenser pad area requires clearance of debris and animal waste prior to installation. Verified current system operational status and photographed equipment configuration including furnace, air handler, ductwork connections, and PVC condensate drainage lines for replacement planning purposes.
Completed comprehensive Gold AC inspection on 13-year-old residential air conditioning system with furnace-mounted air handler. Performed electrical diagnostics using digital multimeter, recording amperage draw of 95.00A and verifying proper system operation. Inspected outdoor condenser unit, confirming fan assembly, heat exchange coils, and cabinet components are in good working condition with no visible damage or deterioration.
Conducted on-site evaluation for air conditioning system replacement estimate. Assessed existing 40-year-old outdoor AC unit located in backyard, inspected indoor air handler and ductwork system in basement utility area, and documented current HVAC configuration including metal ductwork connections, refrigerant lines, and electrical components to provide comprehensive replacement quote for aging system.
Completed comprehensive estimate for replacement of aging HVAC system and water heater, with water heater exhibiting black substance discharge indicating potential sediment buildup or tank deterioration. Documented existing electrical infrastructure in attic space, including breaker panel configuration and gas piping assembly, to assess compatibility requirements for new equipment installation.
Completed comprehensive Gold AC inspection on residential cooling system with air handler located in basement. Verified unit is operational and under 10 years old. Outdoor condenser unit inspected and found in functional condition with proper placement on pad; advised customer to maintain clear area around condenser free of debris and animal waste for optimal performance and airflow.
Completed comprehensive AC tune-up on 27-year-old International Comfort air conditioning system. Performed standard cooling maintenance procedures including inspection of outdoor condenser unit (model PA10NA030N0A10AA), verified proper fan operation, checked electrical connections and specifications, cleaned unit components, and confirmed system is operating properly with no issues detected.
Completed preventative maintenance inspection on residential multi-zone HVAC system consisting of Daikin mini-split unit and conventional air conditioning system with furnace located in basement. Both systems are less than 10 years old and operational at time of service. Documented equipment condition through photography, verified proper operation of all components including condensate removal systems, inspected refrigerant lines and PVC drainage configuration, and confirmed all safety labels and warning stickers present on equipment.
Completed comprehensive Gold AC Inspection on Lennox air conditioning system under 10 years of age with evaporator coil located in basement. Performed thorough evaluation of outdoor condenser unit, which was found to be in excellent condition with clean exterior surfaces, no visible damage or corrosion, and proper fan assembly operation. Unit is properly positioned on mulch base with adequate clearance and ventilation through side louvers functioning as designed.
Completed comprehensive AC tune-up on brand new outdoor condenser unit. Performed full system inspection including refrigerant line check, electrical connections verification, and condenser coil assessment. Unit operating within manufacturer specifications with all components functioning properly and no deficiencies noted.
Completed comprehensive tune-up on residential forced-air furnace (September 2016) and air conditioning system located in basement. Performed full system inspection including visual examination of furnace internal components, blower motor assembly, electrical connections, and control board. Verified proper operation of all safety controls and sequencing. Inspected outdoor condensing unit mounted on concrete pad adjacent to building, noting satisfactory condition of unit housing, protective grilles, and refrigerant line set routing. Checked electrical disconnect box and copper line connections at exterior wall penetration. Customer reported humidifier experiencing operational issues; noted for further evaluation. Both heating and cooling systems confirmed operational at time of service, with equipment showing normal wear consistent with age of installation.
Provided comprehensive estimate for replacement of 10+ year old residential HVAC system including outdoor AC condenser unit (currently an XL 1200 model) and basement-installed Carrier natural gas furnace with air handler. Evaluated existing equipment configuration including ductwork, condensate drainage lines, and electrical connections to determine specifications for new system installation.
Completed commercial rooftop unit installation at a multi-tenant commercial facility. Removed existing aging RTU and disposed of unit according to EPA regulations. Installed new high-efficiency rooftop package unit with appropriate tonnage for the commercial space requirements. Set unit on existing curb adapter, verified structural integrity of roof mounting, and ensured proper weight distribution. Established all refrigerant line connections with nitrogen purge, performed vacuum test to 500 microns, and charged system to manufacturer specifications. Connected all electrical service including disconnect, control wiring, and thermostat integration. Installed new economizer damper assembly and configured fresh air intake controls. Ran condensate drain lines with proper pitch and trap installation. Completed full system startup including compressor staging, blower motor operation, and safety control verification. Tested heating and cooling modes through complete cycles, confirmed proper a
Responded to water leak in breakfast area ceiling. Upon arrival, discovered active leak had caused significant ceiling damage requiring exploratory access. Created access opening in ceiling to expose plumbing infrastructure and wooden joists above, revealing water-damaged drywall with irregular deterioration pattern. Traced leak source through ceiling cavity by inspecting visible plumbing lines and framing members. Documented extent of water damage to ceiling material and structural components for repair assessment.
Completed comprehensive Gold AC inspection on operational system with air handler located in basement. Verified proper operation of under-10-year-old equipment and documented outdoor condenser unit condition with cylindrical white housing positioned on ground pad with mulch base. Advised customer to maintain clear area around condenser unit, removing any debris and animal waste to ensure optimal airflow and system performance.
Completed comprehensive Gold Plan AC inspection on 5-year-old residential cooling system with air handler located in basement. Unit found operating properly with condenser positioned on exterior pad against brick wall. Performed standard diagnostic measurements including voltage readings of 295V at disconnect, inspected condenser coil condition, verified fan operation, and checked refrigerant levels. Advised customer to maintain clear area around outdoor unit by removing debris, wood chips, and any animal waste to ensure proper airflow and system efficiency.