Efficient Heating and Cooling Services in Grosse Pointe, MI

With average temperatures in Grosse Pointe reaching lows of around 16 degrees Fahrenheit in the winter and highs of around 77 degrees Fahrenheit in the summer, you want to ensure you and your family remain warm or cool all year round. 

The team at FLAME Heating, Cooling, Plumbing & Electrical can take care of all your heating and cooling in Grosse Point and surrounding areas. As your go-to HVAC provider in Michigan, we can help keep your home comfortable in all seasons.

Schedule Your Service Today!

Furnace Repair and Installation in Grosse Point

Furnaces keep your home warm even in the coldest months, and we can work with any brand or model. We provide the following furnace services:

  • Furnace installation: Our technicians can install an electric or gas furnace and will do all the checks to make sure it’s running smoothly.
  • Furnace maintenance and repair: If you notice your furnace is acting unusually and not providing enough heat, our team can help. We’ll inspect the unit and complete the required repairs.

Other types of heaters we install include:

  1. Combination boilers
  2. Boilers
  3. Heat pumps
  4. Ductless mini-splits
  5. Packaged units

AC Repair and Installation

Whether you want a ductless mini-split system or another air conditioning unit, FLAME Heating, Cooling, Plumbing & Electrical has the solutions to keep you cool and comfortable during the hot months. Our AC services include:

  • AC installation: No project is too big or small for us. We’ll install the AC unit, set up the connections, and run the tests. Rest assured of comprehensive assistance when you choose us.
  • AC maintenance and repair: If you’re looking for AC repair services in Grosse Pointe, you have come to the right place. As soon as you schedule a service with us, our technicians will drive to your home and restore your AC so it’s working as usual again.

Why Work With FLAME Heating, Cooling, Plumbing & Electrical?

Our team goes above and beyond, using quality tools, brands, and the latest industry technology to upgrade or repair your HVAC system. Our goal is for you to be comfortable in your living spaces and happy with your unit, which is why we provide the highest quality products and services.

Trusted HVAC Services

We only employ skilled and experienced HVAC technicians, allowing us to offer premium HVAC services in Grosse Point.

Fast Response in the Local Area

At FLAME Heating, Cooling, Plumbing & Electrical, we respect your time and want to install or repair your system as quickly as possible. That’s why we respond fast to your Grosse Pointe HVAC needs.

Competitive, Transparent Pricing

Get value for your money and budget with ease with our reasonable, transparent prices.

Contact Us Today for Reliable Heating and Cooling Services

Get started and schedule your appointment by calling us at 586-271-8813 or contacting us online.

Recent Jobs and Reviews in Grosse Pointe , MI

Grosse Pointe, MI at a glance

Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Grosse Pointe, MI in July 2026.

The most recent job was on July 30, 2026.

Job Locations and Reviews

Installed new refrigerant line-sets through underground PVC conduit previously installed by plumbing contractor, running from foundation penetration point through excavated trench in yard. Evacuated and charged system with refrigerant to manufacturer specifications, ensuring proper operation of HVAC equipment.
Installed new refrigerant line-sets through underground PVC conduit previously installed by plumbing contractor, running from foundation penetration point through excavated trench in yard. Evacuated and charged system with refrigerant to manufacturer specifications, ensuring proper operation of HVAC equipment.
FL C.
FL C. Checked in
Installed new refrigerant line-sets through underground PVC conduit previously installed by plumbing contractor, running from foundation penetration point through excavated trench in yard. Evacuated and charged system with refrigerant to manufacturer specifications, ensuring proper operation of HVAC equipment.
Grosse Pointe, MI 48230
Grosse Pointe, MI - Completed comprehensive Gold AC Inspection on a 5-year-old residential air conditioning system with outdoor condensing unit and basement-located air handler. Performed full system evaluation including visual inspection of exterior unit showing proper installation on concrete pad with adequate clearance, verified refrigerant line integrity, checked electrical connections and conduit routing, and confirmed operational status of all components. Unit demonstrated normal outdoor weathering with no significant deterioration, proper airflow through louvers, and functional fan operation with protective grille intact.
FL P.
FL P. Checked in
Completed comprehensive Gold AC Inspection on a 5-year-old residential air conditioning system with outdoor condensing unit and basement-located air handler. Performed full system evaluation including visual inspection of exterior unit showing proper installation on concrete pad with adequate clearance, verified refrigerant line integrity, checked electrical connections and conduit routing, and confirmed operational status of all components. Unit demonstrated normal outdoor weathering with no significant deterioration, proper airflow through louvers, and functional fan operation with protective grille intact.
Grosse Pointe, MI 48230
Excavated trench through residential yard following Miss Dig ticket #206072403970 clearance to install underground plumbing line. Trenched from exterior HVAC pad area through landscaped section and across lawn, installed white PVC piping system at proper grade and depth per code requirements, with soil berms maintained along trench edges for backfill.
Excavated trench through residential yard following Miss Dig ticket #206072403970 clearance to install underground plumbing line. Trenched from exterior HVAC pad area through landscaped section and across lawn, installed white PVC piping system at proper grade and depth per code requirements, with soil berms maintained along trench edges for backfill.
FL C.
FL C. Checked in
Excavated trench through residential yard following Miss Dig ticket #206072403970 clearance to install underground plumbing line. Trenched from exterior HVAC pad area through landscaped section and across lawn, installed white PVC piping system at proper grade and depth per code requirements, with soil berms maintained along trench edges for backfill.
Grosse Pointe, MI 48230
Responded to service call for no airflow from vents and lack of cooling. Performed system evaluation of existing air conditioning unit with unknown age and heating capability status. Assessed electrical panel configuration and thermostat operation. Documented equipment conditions and provided replacement estimate for HVAC system upgrade.
Responded to service call for no airflow from vents and lack of cooling. Performed system evaluation of existing air conditioning unit with unknown age and heating capability status. Assessed electrical panel configuration and thermostat operation. Documented equipment conditions and provided replacement estimate for HVAC system upgrade.
FL S.
FL S. Checked in
Responded to service call for no airflow from vents and lack of cooling. Performed system evaluation of existing air conditioning unit with unknown age and heating capability status. Assessed electrical panel configuration and thermostat operation. Documented equipment conditions and provided replacement estimate for HVAC system upgrade.
Grosse pointe, MI 48230
Completed comprehensive tune-up service on residential forced-air furnace and air conditioning system located in basement. Performed full inspection of furnace burner assembly, heat exchanger, blower motor, electrical controls, and gas connections; verified proper operation of all safety systems and cleaned burner compartment. Inspected AC unit including refrigerant levels, electrical components, and condensate drainage; both systems tested and confirmed operating within manufacturer specifications.
Completed comprehensive tune-up service on residential forced-air furnace and air conditioning system located in basement. Performed full inspection of furnace burner assembly, heat exchanger, blower motor, electrical controls, and gas connections; verified proper operation of all safety systems and cleaned burner compartment. Inspected AC unit including refrigerant levels, electrical components, and condensate drainage; both systems tested and confirmed operating within manufacturer specifications.
FL S.
FL S. Checked in
Completed comprehensive tune-up service on residential forced-air furnace and air conditioning system located in basement. Performed full inspection of furnace burner assembly, heat exchanger, blower motor, electrical controls, and gas connections; verified proper operation of all safety systems and cleaned burner compartment. Inspected AC unit including refrigerant levels, electrical components, and condensate drainage; both systems tested and confirmed operating within manufacturer specifications.
Grosse Pointe, MI 48230
Replaced deteriorated black iron piping assembly showing severe corrosion and oxidation. The existing vertical pipe section and threaded fittings exhibited heavy rust buildup and structural degradation, posing a leak risk. Installed new black pipe with proper threaded connections and brass fittings to restore system integrity and prevent future water damage.
Replaced deteriorated black iron piping assembly showing severe corrosion and oxidation. The existing vertical pipe section and threaded fittings exhibited heavy rust buildup and structural degradation, posing a leak risk. Installed new black pipe with proper threaded connections and brass fittings to restore system integrity and prevent future water damage.
FL B.
FL B. Checked in
Replaced deteriorated black iron piping assembly showing severe corrosion and oxidation. The existing vertical pipe section and threaded fittings exhibited heavy rust buildup and structural degradation, posing a leak risk. Installed new black pipe with proper threaded connections and brass fittings to restore system integrity and prevent future water damage.
Grosse Pointe, MI 48230
Responded to no cooling complaint with no air flow from vents. Upon arrival, found outdoor condensing unit in severely deteriorated condition with extensive rust damage on cabinet panels and internal components. Unit interior contained heavy accumulation of leaves, dirt, and organic debris surrounding electrical components including capacitor and wiring connections. Exterior cabinet showed significant corrosion along edges and panels with weathering from prolonged exposure to elements. Removed debris from unit interior and assessed electrical connections. Due to extensive rust damage compromising structural integrity and potential electrical hazards from moisture infiltration around capacitor and wiring, recommended unit replacement rather than repair given safety concerns and deteriorated condition of components.
Responded to no cooling complaint with no air flow from vents. Upon arrival, found outdoor condensing unit in severely deteriorated condition with extensive rust damage on cabinet panels and internal components. Unit interior contained heavy accumulation of leaves, dirt, and organic debris surrounding electrical components including capacitor and wiring connections. Exterior cabinet showed significant corrosion along edges and panels with weathering from prolonged exposure to elements. Removed debris from unit interior and assessed electrical connections. Due to extensive rust damage compromising structural integrity and potential electrical hazards from moisture infiltration around capacitor and wiring, recommended unit replacement rather than repair given safety concerns and deteriorated condition of components.
FL W.
FL W. Checked in
Responded to no cooling complaint with no air flow from vents. Upon arrival, found outdoor condensing unit in severely deteriorated condition with extensive rust damage on cabinet panels and internal components. Unit interior contained heavy accumulation of leaves, dirt, and organic debris surrounding electrical components including capacitor and wiring connections. Exterior cabinet showed significant corrosion along edges and panels with weathering from prolonged exposure to elements. Removed debris from unit interior and assessed electrical connections. Due to extensive rust damage compromising structural integrity and potential electrical hazards from moisture infiltration around capacitor and wiring, recommended unit replacement rather than repair given safety concerns and deteriorated condition of components.
Grosse pointe, MI 48230
Returned to site to complete lineset repair on leaking refrigerant line. Successfully pumped down system and recovered refrigerant from affected lineset while ensuring live unit remained undisturbed per specifications. Performed nitrogen pressure test to verify leak location and system integrity. Cut in new ball valve on the compromised copper lineset section. Pulled deep vacuum to remove moisture and contaminants from repaired section. System held vacuum successfully, confirming leak repair. Restored refrigerant charge and verified proper operation without disturbing existing operational equipment.
Returned to site to complete lineset repair on leaking refrigerant line. Successfully pumped down system and recovered refrigerant from affected lineset while ensuring live unit remained undisturbed per specifications. Performed nitrogen pressure test to verify leak location and system integrity. Cut in new ball valve on the compromised copper lineset section. Pulled deep vacuum to remove moisture and contaminants from repaired section. System held vacuum successfully, confirming leak repair. Restored refrigerant charge and verified proper operation without disturbing existing operational equipment.
FL B.
FL B. Checked in
Returned to site to complete lineset repair on leaking refrigerant line. Successfully pumped down system and recovered refrigerant from affected lineset while ensuring live unit remained undisturbed per specifications. Performed nitrogen pressure test to verify leak location and system integrity. Cut in new ball valve on the compromised copper lineset section. Pulled deep vacuum to remove moisture and contaminants from repaired section. System held vacuum successfully, confirming leak repair. Restored refrigerant charge and verified proper operation without disturbing existing operational equipment.
Grosse Pointe, MI 48230
Completed comprehensive Gold AC Inspection on two 5-year-old Lennox air conditioning systems serving a multi-level residence. Performed thorough evaluation of both outdoor condenser units, inspecting refrigerant lines, electrical connections, and overall equipment condition. Both systems were operational at time of service, with units showing normal wear consistent with age and outdoor exposure. Documented equipment condition through detailed photography for maintenance records.
Completed comprehensive Gold AC Inspection on two 5-year-old Lennox air conditioning systems serving a multi-level residence. Performed thorough evaluation of both outdoor condenser units, inspecting refrigerant lines, electrical connections, and overall equipment condition. Both systems were operational at time of service, with units showing normal wear consistent with age and outdoor exposure. Documented equipment condition through detailed photography for maintenance records.
FL Z.
FL Z. Checked in
Completed comprehensive Gold AC Inspection on two 5-year-old Lennox air conditioning systems serving a multi-level residence. Performed thorough evaluation of both outdoor condenser units, inspecting refrigerant lines, electrical connections, and overall equipment condition. Both systems were operational at time of service, with units showing normal wear consistent with age and outdoor exposure. Documented equipment condition through detailed photography for maintenance records.
Grosse Pointe, MI 48230
Grosse Pointe, MI - Performed routine furnace maintenance on approximately 100-year-old heating unit located in basement. Completed comprehensive tune-up including inspection of boiler system, associated piping, pressure gauges, circulator components, and related mechanical systems. All equipment inspected and serviced per manufacturer specifications with system confirmed operational upon completion.
FL H.
FL H. Checked in
Performed routine furnace maintenance on approximately 100-year-old heating unit located in basement. Completed comprehensive tune-up including inspection of boiler system, associated piping, pressure gauges, circulator components, and related mechanical systems. All equipment inspected and serviced per manufacturer specifications with system confirmed operational upon completion.
Grosse Pointe, MI 48230
Grosse Pointe, MI - Responded to no-cooling complaint on 12-year-old residential AC system with attic-mounted air handler and ground-level condenser unit. Upon arrival, confirmed system was running but delivering only tepid air with no cooling capacity. Performed diagnostic evaluation of outdoor condenser unit, which showed signs of age-related wear and weathering, and documented equipment condition with photos for service records.
FL P.
FL P. Checked in
Responded to no-cooling complaint on 12-year-old residential AC system with attic-mounted air handler and ground-level condenser unit. Upon arrival, confirmed system was running but delivering only tepid air with no cooling capacity. Performed diagnostic evaluation of outdoor condenser unit, which showed signs of age-related wear and weathering, and documented equipment condition with photos for service records.
Grosse Pointe, MI 48230
Completed comprehensive Gold AC Inspection on multi-unit residential HVAC system consisting of two outdoor condensing units: one Lennox unit and one Bryant unit, both positioned on exterior concrete pads against brick wall. Performed thorough visual inspection of both condenser units, evaluated physical condition of cabinets showing normal outdoor weathering, verified proper installation on concrete pads, inspected fan guards and louvers for adequate airflow, checked refrigerant labels (Puron), and documented equipment specifications. Noted minor organic growth accumulation around unit bases and dirt buildup consistent with outdoor exposure, though both units remain operational. Equipment located at basement and side of house positions, with upstairs unit being newer installation. All components inspected and photographed for maintenance records.
Completed comprehensive Gold AC Inspection on multi-unit residential HVAC system consisting of two outdoor condensing units: one Lennox unit and one Bryant unit, both positioned on exterior concrete pads against brick wall. Performed thorough visual inspection of both condenser units, evaluated physical condition of cabinets showing normal outdoor weathering, verified proper installation on concrete pads, inspected fan guards and louvers for adequate airflow, checked refrigerant labels (Puron), and documented equipment specifications. Noted minor organic growth accumulation around unit bases and dirt buildup consistent with outdoor exposure, though both units remain operational. Equipment located at basement and side of house positions, with upstairs unit being newer installation. All components inspected and photographed for maintenance records.
FL H.
FL H. Checked in
Completed comprehensive Gold AC Inspection on multi-unit residential HVAC system consisting of two outdoor condensing units: one Lennox unit and one Bryant unit, both positioned on exterior concrete pads against brick wall. Performed thorough visual inspection of both condenser units, evaluated physical condition of cabinets showing normal outdoor weathering, verified proper installation on concrete pads, inspected fan guards and louvers for adequate airflow, checked refrigerant labels (Puron), and documented equipment specifications. Noted minor organic growth accumulation around unit bases and dirt buildup consistent with outdoor exposure, though both units remain operational. Equipment located at basement and side of house positions, with upstairs unit being newer installation. All components inspected and photographed for maintenance records.
Grosse Pointe, MI 48230
Completed Gold AC Inspection and tune-up on outdoor air conditioning unit. Performed comprehensive system evaluation including inspection of condenser unit, electrical components, refrigerant lines, and condensate drainage system. Cleaned exterior surfaces of condenser unit, removed debris and organic matter from surrounding area and equipment base. Verified proper operation of all mechanical and electrical components, checked mounting hardware and pipe connections for integrity, and confirmed adequate drainage function through Schedule 40 PVC condensate line. System operational with no deficiencies noted at time of service.
Completed Gold AC Inspection and tune-up on outdoor air conditioning unit. Performed comprehensive system evaluation including inspection of condenser unit, electrical components, refrigerant lines, and condensate drainage system. Cleaned exterior surfaces of condenser unit, removed debris and organic matter from surrounding area and equipment base. Verified proper operation of all mechanical and electrical components, checked mounting hardware and pipe connections for integrity, and confirmed adequate drainage function through Schedule 40 PVC condensate line. System operational with no deficiencies noted at time of service.
FL W.
FL W. Checked in
Completed Gold AC Inspection and tune-up on outdoor air conditioning unit. Performed comprehensive system evaluation including inspection of condenser unit, electrical components, refrigerant lines, and condensate drainage system. Cleaned exterior surfaces of condenser unit, removed debris and organic matter from surrounding area and equipment base. Verified proper operation of all mechanical and electrical components, checked mounting hardware and pipe connections for integrity, and confirmed adequate drainage function through Schedule 40 PVC condensate line. System operational with no deficiencies noted at time of service.
Grosse Pointe, MI 48230
Grosse Pointe, MI - Responded to service call for first-floor AC unit not operating. Located equipment in basement with RTU access through garage. Upon inspection, diagnosed failed capacitor on outdoor unit. Replaced defective dual-run capacitor, verified proper electrical connections at contactor and terminals, and tested system operation. Unit restored to normal cooling function with proper amperage draw and temperature differential confirmed.
FL H.
FL H. Checked in
Responded to service call for first-floor AC unit not operating. Located equipment in basement with RTU access through garage. Upon inspection, diagnosed failed capacitor on outdoor unit. Replaced defective dual-run capacitor, verified proper electrical connections at contactor and terminals, and tested system operation. Unit restored to normal cooling function with proper amperage draw and temperature differential confirmed.
Grosse Pointe, MI 48230
Grosse Pointe, MI - Responded to service call for 13kW Briggs & Stratton generator that failed to restore power to residence following utility company repairs in the neighborhood. Performed diagnostic inspection of generator system and transfer switch control board. Inspected internal control panel components, circuit board connections, terminal blocks, and wiring harness for damage or fault conditions. Documented control board condition with photos showing PCB assembly, LED indicators, relay components, and wire terminations. Determined transfer switch control board requires replacement, with unit available at shop for installation.
FL H.
FL H. Checked in
Responded to service call for 13kW Briggs & Stratton generator that failed to restore power to residence following utility company repairs in the neighborhood. Performed diagnostic inspection of generator system and transfer switch control board. Inspected internal control panel components, circuit board connections, terminal blocks, and wiring harness for damage or fault conditions. Documented control board condition with photos showing PCB assembly, LED indicators, relay components, and wire terminations. Determined transfer switch control board requires replacement, with unit available at shop for installation.
Grosse Pointe, MI 48230
Grosse Pointe, MI - Responded to recurring leak on boiler piping in basement of century-old home. Upon inspection, identified compromised threaded connection on vertical black iron pipe with copper fittings showing significant corrosion and green oxidation buildup. Disassembled affected section, cleaned threads, applied new thread sealant, and reassembled connection to manufacturer specifications. Pressure tested system to verify leak elimination and monitored for stability. Documented existing condition with photos for warranty consideration.
FL P.
FL P. Checked in
Responded to recurring leak on boiler piping in basement of century-old home. Upon inspection, identified compromised threaded connection on vertical black iron pipe with copper fittings showing significant corrosion and green oxidation buildup. Disassembled affected section, cleaned threads, applied new thread sealant, and reassembled connection to manufacturer specifications. Pressure tested system to verify leak elimination and monitored for stability. Documented existing condition with photos for warranty consideration.
Grosse Pointe, MI 48230
Responded to report of water leaking from bottom of furnace unit located in basement. Upon inspection, identified condensate drainage issue causing water accumulation on concrete floor around base of heating system. Cleared blocked condensate drain line, verified proper drainage flow, and confirmed no additional leaks from heat exchanger or other components. System tested and operating normally with condensate now draining properly through PVC drainage system.
Responded to report of water leaking from bottom of furnace unit located in basement. Upon inspection, identified condensate drainage issue causing water accumulation on concrete floor around base of heating system. Cleared blocked condensate drain line, verified proper drainage flow, and confirmed no additional leaks from heat exchanger or other components. System tested and operating normally with condensate now draining properly through PVC drainage system.
FL C.
FL C. Checked in
Responded to report of water leaking from bottom of furnace unit located in basement. Upon inspection, identified condensate drainage issue causing water accumulation on concrete floor around base of heating system. Cleared blocked condensate drain line, verified proper drainage flow, and confirmed no additional leaks from heat exchanger or other components. System tested and operating normally with condensate now draining properly through PVC drainage system.
Grosse Pointe, MI 48230
Completed comprehensive AC tune-up on 15-year-old air conditioning system with no reported symptoms or operational issues. Performed standard preventive maintenance procedures including inspection of all major components, refrigerant level verification, electrical connection testing, condenser and evaporator coil examination, air filter assessment, thermostat calibration check, and condensate drain line verification. System found to be operating within normal parameters with all components functioning properly at time of service.
Completed comprehensive AC tune-up on 15-year-old air conditioning system with no reported symptoms or operational issues. Performed standard preventive maintenance procedures including inspection of all major components, refrigerant level verification, electrical connection testing, condenser and evaporator coil examination, air filter assessment, thermostat calibration check, and condensate drain line verification. System found to be operating within normal parameters with all components functioning properly at time of service.
FL P.
FL P. Checked in
Completed comprehensive AC tune-up on 15-year-old air conditioning system with no reported symptoms or operational issues. Performed standard preventive maintenance procedures including inspection of all major components, refrigerant level verification, electrical connection testing, condenser and evaporator coil examination, air filter assessment, thermostat calibration check, and condensate drain line verification. System found to be operating within normal parameters with all components functioning properly at time of service.
Grosse Pointe, MI 48230
Replaced a non-functioning 75-gallon Bradford White water heater under warranty with a new 75-gallon Bradford White unit. Connected copper supply lines, pressure relief valve, and all necessary plumbing connections to restore hot water service. Expansion tank installation to be scheduled for follow-up visit.
Replaced a non-functioning 75-gallon Bradford White water heater under warranty with a new 75-gallon Bradford White unit. Connected copper supply lines, pressure relief valve, and all necessary plumbing connections to restore hot water service. Expansion tank installation to be scheduled for follow-up visit.
FL A.
FL A. Checked in
Replaced a non-functioning 75-gallon Bradford White water heater under warranty with a new 75-gallon Bradford White unit. Connected copper supply lines, pressure relief valve, and all necessary plumbing connections to restore hot water service. Expansion tank installation to be scheduled for follow-up visit.
Grosse Pointe, MI 48230
Responded to service call for uneven cooling with upstairs area measuring 15 degrees warmer than downstairs despite newer system maintaining heating and cooling capability. Performed diagnostic evaluation of central air conditioning system and ductwork distribution. Inspected floor-mounted supply registers and vents throughout home, identifying potential airflow restriction issues at multiple locations with visible dirt accumulation and possible damper positioning concerns that could contribute to inadequate second-floor cooling performance.
Responded to service call for uneven cooling with upstairs area measuring 15 degrees warmer than downstairs despite newer system maintaining heating and cooling capability. Performed diagnostic evaluation of central air conditioning system and ductwork distribution. Inspected floor-mounted supply registers and vents throughout home, identifying potential airflow restriction issues at multiple locations with visible dirt accumulation and possible damper positioning concerns that could contribute to inadequate second-floor cooling performance.
FL W.
FL W. Checked in
Responded to service call for uneven cooling with upstairs area measuring 15 degrees warmer than downstairs despite newer system maintaining heating and cooling capability. Performed diagnostic evaluation of central air conditioning system and ductwork distribution. Inspected floor-mounted supply registers and vents throughout home, identifying potential airflow restriction issues at multiple locations with visible dirt accumulation and possible damper positioning concerns that could contribute to inadequate second-floor cooling performance.
Grosse Pointe, MI 48230
financing-img
Heartland Academy Learn More

What To Expect

Discover the Difference
Satisfaction Guaranteed
Licensed & Insured Services
Upfront & Fair Pricing
Background Checked Technicians
Satisfaction Guaranteed
Licensed & Insured Services
Upfront & Fair Pricing
Background Checked Technicians
discover the difference
Review Image
Our Reviews

See What Your Neighbors Are Saying

When our old furnace quit working in mid-January we called FLAME to look at it. They came right out. They send a message or email when they are on their way to you. They did a great job and were very professional and tidy about their…

Poilin B.

Poilin B.

We contacted FLAME due to a gas leak at our church. It was very nice that they sent a text message with the technician’s name photo and estimated arrival time. I feel that they went above their service responsibilities by offering to work with the gas…

Danielle K.

Danielle K.

This is my first time experience and I am completely satisfied with the speed and courtesy of the company. I called the company I had been using for over 20 years to fix my central air and was given a date 8 days out...seriously?! One call…

Tina M.

Tina M.

Used this company twice, one for a same day gas line install for my dryer and then as a second opinion on an alleged leak and low refrigerant on my AC unit per another company. Turns out that there is no leak and the refrigerant levels…

Chris S.

Chris S.

I have had some bad experiences in the recent past with other contractors. FLAME has been a god send and are in the process of fixing all my issues at a reasonable price. I am a gold member and they have already installed and serviced my…

Sandra K.

Sandra K.

Hear What Our Customers Are Saying

Learn why so many choose FLAME Heating, Cooling, Plumbing & Electrical for all their HVAC, plumbing, and electrical needs.

When our old furnace quit working in mid-January we called FLAME to look at it. They came right out. They send a message or email when they are on their way to you. They did a great job and were very professional and tidy about their work. A great crew that worked well with each other.…

Poilin B.

Poilin B.

We contacted FLAME due to a gas leak at our church. It was very nice that they sent a text message with the technician’s name photo and estimated arrival time. I feel that they went above their service responsibilities by offering to work with the gas company to find the problem. Throughout this process we also…

Danielle K.

Danielle K.

This is my first time experience and I am completely satisfied with the speed and courtesy of the company. I called the company I had been using for over 20 years to fix my central air and was given a date 8 days out...seriously?! One call to FLAME and they had Jeff out within a few…

Tina M.

Tina M.

Used this company twice, one for a same day gas line install for my dryer and then as a second opinion on an alleged leak and low refrigerant on my AC unit per another company. Turns out that there is no leak and the refrigerant levels are fine. All of FLAME technicians that I have worked…

Chris S.

Chris S.

I have had some bad experiences in the recent past with other contractors. FLAME has been a god send and are in the process of fixing all my issues at a reasonable price. I am a gold member and they have already installed and serviced my furnace, AC and water heater. Thank you for always being…

Sandra K.

Sandra K.