Heating and Cooling Northville

Homeownership comes with its fair share of unexpected problems. One day, everything’s running smoothly, and the next, your furnace won’t turn on, your kitchen sink won’t drain, or a power outage leaves you in the dark. That’s when you need a team you can count on. At FLAME Heating, Cooling, Plumbing & Electrical, we’ve been helping homeowners for over 70 years, delivering reliable solutions with skilled service you can trust.When your home throws you a curveball, call Flame at (586) 217-2512 for our Northville home services or schedule your service online!

Reliable Plumbing Services in Northville for a Stress-Free Home

Instant tankless electric water heater installed on white tile wall with input and output pipe outlet and elcb safety breaker system

Plumbing problems always seem to happen when you least expect them. Whether it’s a backed-up sink when you’re hosting dinner or a burst pipe in the middle of the night, quick action is key. Our plumbers in Northville are here to respond fast, fix the issue efficiently, and make sure your home’s plumbing is working the way it should—so you can get back to your routine without the hassle.

Schedule Your Service Today!

Trusted Northville Electrical Services

When electrical problems pop up, they can be more than just frustrating—they can affect your entire home’s functionality and safety. Whether you’re dealing with flickering lights, outlets that suddenly stop working, or need outlets installed outdoors, you need solutions that last. The FLAME team of skilled electricians in Northville handle everything from troubleshooting minor issues to installing modern, energy-efficient upgrades that keep your home running smoothly and safely. 

Electrical Panel Upgrades

Modern Northville homes require more power than ever. If your electrical panel is outdated, we provide expert upgrades to ensure your home can handle today’s energy demands safely and efficiently.

Circuit Breaker Repairs

Frequent breaker trips or non-working outlets can indicate an underlying electrical issue. Our Northville electricians identify and fix these problems to keep your home running smoothly.

Northville Lighting Installation

Whether you need upgraded interior lighting or enhanced outdoor security lighting, we install high-quality fixtures that improve both function and aesthetics.

Ceiling Fan Installation

Improve air circulation and reduce energy costs with a professionally installed ceiling fan. We handle the wiring and setup for safe and efficient operation.

Whole-Home Surge Protection

Unexpected power surges can damage your appliances and electronics. Our whole-home surge protection solutions keep your home and devices safe.

Smart Home Installations in Northville

Upgrade your home with smart lighting, thermostats, and security systems. We integrate the latest technology for convenience, security, and energy efficiency.

EV Charging Stations

With electric vehicles becoming more common, a home charging station is essential. We install EV chargers for convenient and safe vehicle charging at home.

Backup Generators

Power outages don’t have to leave you in the dark. Our professionally installed backup generators keep your home running when the grid goes down.

Dependable Heating & Cooling in Northville for Year-Round Comfort

HVAC technician

In Northville, the weather doesn’t always play nice—one day, you’re layering up for the cold, and the next, you’re looking for relief from the heat. Your home’s heating and cooling systems shouldn’t struggle to keep up. At FLAME, we make sure your HVAC system operates reliably with our Northville heating and cooling services, so you stay comfortable no matter how unpredictable the forecast gets.

Cooling Services

Schedule Your Service Today!

Heating Services

  • Northville Furnace Repair & Installation – Whether your furnace isn’t heating efficiently or has stopped working altogether, we diagnose the problem quickly and offer energy-efficient replacement options if needed.
  • Boiler Services – Our technicians service and install high-efficiency boiler systems to keep your home warm without skyrocketing energy costs.
  • Heat Pump Installation & Repairs – A heat pump is a cost-effective solution for year-round comfort, and we provide expert installation and maintenance.
  • Heating Tune-Ups – Regular maintenance helps prevent breakdowns and extends the lifespan of your heating system.

Why Northville Homeowners Can Trust FLAME

  • Certified & Skilled Technicians – Our highly trained experts bring years of experience in HVAC, plumbing, and electrical services.
  • Transparent Pricing & Honest Service – No surprises, no hidden fees—just straightforward pricing before we start any work.
  • 24/7 Emergency Service – We’re available when you need us most, providing fast and reliable repairs.
  • Top-Quality Craftsmanship & Materials – We use only high-grade materials and trusted products for long-lasting results.
  • Satisfaction Guaranteed – Your comfort and safety are our top priorities, and we’re not happy until you are.

Book your Appointment with FLAME Today

Your home deserves expert care, and FLAME is here to provide it. Whether you need a repair, a system upgrade, or preventative maintenance, we’re ready to help. Contact us today by calling (586) 217-2512 to schedule an appointment and experience home service that puts your comfort first.

 

Recent Jobs and Reviews in Northville , MI

Northville, MI at a glance

Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Northville, MI between May 2026 and June 2026.

The most recent job was on June 22, 2026.

Job Locations and Reviews

Completed toilet installation to address active leak at fixture base. Removed existing toilet, inspected flange and wax ring, and installed new toilet with proper sealing to prevent future water intrusion. Connected braided stainless steel flexible supply line to fill valve with secure fittings. Water damage evident on surrounding wall surfaces indicated previous long-term leakage from failed seal, which has been corrected with new installation.
Completed toilet installation to address active leak at fixture base. Removed existing toilet, inspected flange and wax ring, and installed new toilet with proper sealing to prevent future water intrusion. Connected braided stainless steel flexible supply line to fill valve with secure fittings. Water damage evident on surrounding wall surfaces indicated previous long-term leakage from failed seal, which has been corrected with new installation.
FL S.
FL S. Checked in
Completed toilet installation to address active leak at fixture base. Removed existing toilet, inspected flange and wax ring, and installed new toilet with proper sealing to prevent future water intrusion. Connected braided stainless steel flexible supply line to fill valve with secure fittings. Water damage evident on surrounding wall surfaces indicated previous long-term leakage from failed seal, which has been corrected with new installation.
Northville, MI 48168
Northville, MI - Responded to no cooling complaint on 10-year-old air conditioning system with equipment located in basement. Upon arrival, performed diagnostic testing on outdoor condensing unit using clamp meter to measure electrical current draw on compressor and fan motor circuits, recording amperage readings of 17.58A and 27.97A. Conducted thorough inspection of outdoor unit components, electrical connections, and refrigerant system to identify root cause of cooling failure and determine appropriate repair recommendations.
FL K.
FL K. Checked in
Responded to no cooling complaint on 10-year-old air conditioning system with equipment located in basement. Upon arrival, performed diagnostic testing on outdoor condensing unit using clamp meter to measure electrical current draw on compressor and fan motor circuits, recording amperage readings of 17.58A and 27.97A. Conducted thorough inspection of outdoor unit components, electrical connections, and refrigerant system to identify root cause of cooling failure and determine appropriate repair recommendations.
Northville, MI 48167
Assessed plumbing requirements for upcoming Aprilaire humidifier installation in basement utility area. Determined need for new shut-off valve and dedicated water supply line to support HVAC humidifier system being installed by HVAC technician. Coordinated with office to schedule humidifier installation upon completion of plumbing work.
Assessed plumbing requirements for upcoming Aprilaire humidifier installation in basement utility area. Determined need for new shut-off valve and dedicated water supply line to support HVAC humidifier system being installed by HVAC technician. Coordinated with office to schedule humidifier installation upon completion of plumbing work.
FL C.
FL C. Checked in
Assessed plumbing requirements for upcoming Aprilaire humidifier installation in basement utility area. Determined need for new shut-off valve and dedicated water supply line to support HVAC humidifier system being installed by HVAC technician. Coordinated with office to schedule humidifier installation upon completion of plumbing work.
Northville, MI 48168
Completed Gold AC Inspection on Bryant air conditioning system with air handler located in basement. Performed comprehensive inspection of outdoor condenser unit, which was found in good operational condition with clean exterior housing and properly functioning components. Replaced Totaline LBP/600/700/760 humidifier water panel pad to ensure proper humidification throughout the home.
Completed Gold AC Inspection on Bryant air conditioning system with air handler located in basement. Performed comprehensive inspection of outdoor condenser unit, which was found in good operational condition with clean exterior housing and properly functioning components. Replaced Totaline LBP/600/700/760 humidifier water panel pad to ensure proper humidification throughout the home.
FL W.
FL W. Checked in
Completed Gold AC Inspection on Bryant air conditioning system with air handler located in basement. Performed comprehensive inspection of outdoor condenser unit, which was found in good operational condition with clean exterior housing and properly functioning components. Replaced Totaline LBP/600/700/760 humidifier water panel pad to ensure proper humidification throughout the home.
Northville, MI 48167
Completed comprehensive replacement estimate for over 20-year-old AC and furnace system located in basement. Assessed existing HVAC equipment condition, documented current installation configuration including ductwork and venting requirements, and provided homeowner with replacement options for both heating and cooling components.
Completed comprehensive replacement estimate for over 20-year-old AC and furnace system located in basement. Assessed existing HVAC equipment condition, documented current installation configuration including ductwork and venting requirements, and provided homeowner with replacement options for both heating and cooling components.
FL S.
FL S. Checked in
Completed comprehensive replacement estimate for over 20-year-old AC and furnace system located in basement. Assessed existing HVAC equipment condition, documented current installation configuration including ductwork and venting requirements, and provided homeowner with replacement options for both heating and cooling components.
Northville, MI 48168
Responded to no cooling complaint on 4-year-old R-410A air conditioning system located in basement. Upon arrival, found Sensi thermostat displaying 83°F ambient temperature with no cooling mode available. Performed diagnostic evaluation of thermostat wiring and communication between thermostat and CNPVP1A7LAAAAA condenser unit. Inspected equipment specification label confirming R-410A refrigerant system manufactured in 2021 with 450 PSIG design pressure rating. Conducted full system inspection as requested, evaluating electrical connections, refrigerant circuit integrity, and control board functionality. Identified thermostat configuration issue preventing cooling mode activation. Restored proper thermostat settings and verified system communication. Cycled unit through complete operational test, confirming cooling mode now accessible and system responding appropriately to temperature calls. System returned to normal operation with all safety controls functioning properly.
Responded to no cooling complaint on 4-year-old R-410A air conditioning system located in basement. Upon arrival, found Sensi thermostat displaying 83°F ambient temperature with no cooling mode available. Performed diagnostic evaluation of thermostat wiring and communication between thermostat and CNPVP1A7LAAAAA condenser unit. Inspected equipment specification label confirming R-410A refrigerant system manufactured in 2021 with 450 PSIG design pressure rating. Conducted full system inspection as requested, evaluating electrical connections, refrigerant circuit integrity, and control board functionality. Identified thermostat configuration issue preventing cooling mode activation. Restored proper thermostat settings and verified system communication. Cycled unit through complete operational test, confirming cooling mode now accessible and system responding appropriately to temperature calls. System returned to normal operation with all safety controls functioning properly.
FL C.
FL C. Checked in
Responded to no cooling complaint on 4-year-old R-410A air conditioning system located in basement. Upon arrival, found Sensi thermostat displaying 83°F ambient temperature with no cooling mode available. Performed diagnostic evaluation of thermostat wiring and communication between thermostat and CNPVP1A7LAAAAA condenser unit. Inspected equipment specification label confirming R-410A refrigerant system manufactured in 2021 with 450 PSIG design pressure rating. Conducted full system inspection as requested, evaluating electrical connections, refrigerant circuit integrity, and control board functionality. Identified thermostat configuration issue preventing cooling mode activation. Restored proper thermostat settings and verified system communication. Cycled unit through complete operational test, confirming cooling mode now accessible and system responding appropriately to temperature calls. System returned to normal operation with all safety controls functioning properly.
Northville, MI 48167
Completed comprehensive NSP AC inspection on 9-year-old residential cooling system with outdoor condensing unit and basement-located air handler. Performed visual assessment of exterior unit mounted on concrete pad, verified proper installation with adequate clearance, inspected refrigerant lines and condensate drainage system, and evaluated overall equipment condition. Notified homeowner of filter replacement requirement to maintain optimal system performance and air quality.
Completed comprehensive NSP AC inspection on 9-year-old residential cooling system with outdoor condensing unit and basement-located air handler. Performed visual assessment of exterior unit mounted on concrete pad, verified proper installation with adequate clearance, inspected refrigerant lines and condensate drainage system, and evaluated overall equipment condition. Notified homeowner of filter replacement requirement to maintain optimal system performance and air quality.
FL M.
FL M. Checked in
Completed comprehensive NSP AC inspection on 9-year-old residential cooling system with outdoor condensing unit and basement-located air handler. Performed visual assessment of exterior unit mounted on concrete pad, verified proper installation with adequate clearance, inspected refrigerant lines and condensate drainage system, and evaluated overall equipment condition. Notified homeowner of filter replacement requirement to maintain optimal system performance and air quality.
Northville, MI 48168
Completed comprehensive Gold AC Inspection on 2018 residential air conditioning system with outdoor condenser unit located on concrete pad and basement air handler. Performed thorough multi-point inspection including refrigerant level check, electrical connection testing, capacitor evaluation, contactor inspection, and airflow assessment. Verified proper operation of condenser fan motor, examined coil conditions both indoor and outdoor units, inspected condensate drain line for proper drainage, and confirmed thermostat functionality. All components found operating within manufacturer specifications with no immediate repairs required at this time.
Completed comprehensive Gold AC Inspection on 2018 residential air conditioning system with outdoor condenser unit located on concrete pad and basement air handler. Performed thorough multi-point inspection including refrigerant level check, electrical connection testing, capacitor evaluation, contactor inspection, and airflow assessment. Verified proper operation of condenser fan motor, examined coil conditions both indoor and outdoor units, inspected condensate drain line for proper drainage, and confirmed thermostat functionality. All components found operating within manufacturer specifications with no immediate repairs required at this time.
FL M.
FL M. Checked in
Completed comprehensive Gold AC Inspection on 2018 residential air conditioning system with outdoor condenser unit located on concrete pad and basement air handler. Performed thorough multi-point inspection including refrigerant level check, electrical connection testing, capacitor evaluation, contactor inspection, and airflow assessment. Verified proper operation of condenser fan motor, examined coil conditions both indoor and outdoor units, inspected condensate drain line for proper drainage, and confirmed thermostat functionality. All components found operating within manufacturer specifications with no immediate repairs required at this time.
Northville, MI 48167
Completed Gold AC Inspection on a 6-year-old air conditioning system with condenser unit located on exterior concrete pad against brick wall and evaporator coil in basement. Performed comprehensive maintenance including visual inspection of outdoor condenser unit, verified proper positioning on concrete pad with adequate clearance, inspected cabinet housing and protective grilles for structural integrity, and confirmed fan guard assembly secure. Checked condensate drainage system including white PVC piping configuration mounted to exterior wall, verified electrical disconnect box properly installed and accessible. Inspected condenser coil fins through louvers, assessed unit for signs of wear, corrosion, or damage. Evaluated surrounding area including mulch bedding and confirmed no debris obstruction to airflow. Unit operating within normal parameters with clean metal surfaces and no visible deficiencies noted. System demonstrates proper installation standards and maintenance condition
Completed Gold AC Inspection on a 6-year-old air conditioning system with condenser unit located on exterior concrete pad against brick wall and evaporator coil in basement. Performed comprehensive maintenance including visual inspection of outdoor condenser unit, verified proper positioning on concrete pad with adequate clearance, inspected cabinet housing and protective grilles for structural integrity, and confirmed fan guard assembly secure. Checked condensate drainage system including white PVC piping configuration mounted to exterior wall, verified electrical disconnect box properly installed and accessible. Inspected condenser coil fins through louvers, assessed unit for signs of wear, corrosion, or damage. Evaluated surrounding area including mulch bedding and confirmed no debris obstruction to airflow. Unit operating within normal parameters with clean metal surfaces and no visible deficiencies noted. System demonstrates proper installation standards and maintenance condition
FL M.
FL M. Checked in
Completed Gold AC Inspection on a 6-year-old air conditioning system with condenser unit located on exterior concrete pad against brick wall and evaporator coil in basement. Performed comprehensive maintenance including visual inspection of outdoor condenser unit, verified proper positioning on concrete pad with adequate clearance, inspected cabinet housing and protective grilles for structural integrity, and confirmed fan guard assembly secure. Checked condensate drainage system including white PVC piping configuration mounted to exterior wall, verified electrical disconnect box properly installed and accessible. Inspected condenser coil fins through louvers, assessed unit for signs of wear, corrosion, or damage. Evaluated surrounding area including mulch bedding and confirmed no debris obstruction to airflow. Unit operating within normal parameters with clean metal surfaces and no visible deficiencies noted. System demonstrates proper installation standards and maintenance condition
Northville, MI 48168
Northville, MI - Completed Gold AC inspection on system less than 10 years old with air handler located in basement. Unit confirmed operational with condenser positioned on concrete pad with gravel surround. Advised customer to maintain clear area around condenser unit, removing any debris and animal waste to ensure proper airflow and system efficiency.
FL Z.
FL Z. Checked in
Completed Gold AC inspection on system less than 10 years old with air handler located in basement. Unit confirmed operational with condenser positioned on concrete pad with gravel surround. Advised customer to maintain clear area around condenser unit, removing any debris and animal waste to ensure proper airflow and system efficiency.
Northville, MI 48168
Completed comprehensive Gold AC inspection on single residential unit less than 5 years old with air handler located in basement. Performed full system evaluation including outdoor condenser unit inspection, verified proper operation of all components, checked refrigerant levels, inspected electrical connections, and assessed overall system performance. Unit found to be operating within normal parameters with no immediate service needs identified.
Completed comprehensive Gold AC inspection on single residential unit less than 5 years old with air handler located in basement. Performed full system evaluation including outdoor condenser unit inspection, verified proper operation of all components, checked refrigerant levels, inspected electrical connections, and assessed overall system performance. Unit found to be operating within normal parameters with no immediate service needs identified.
FL M.
FL M. Checked in
Completed comprehensive Gold AC inspection on single residential unit less than 5 years old with air handler located in basement. Performed full system evaluation including outdoor condenser unit inspection, verified proper operation of all components, checked refrigerant levels, inspected electrical connections, and assessed overall system performance. Unit found to be operating within normal parameters with no immediate service needs identified.
Northville, MI 48167
Northville, MI - Completed preventive maintenance tune-up on 7-year-old residential HVAC system with indoor evaporator coil located in basement and outdoor condenser unit on patio. Performed standard inspection and service procedures on both components, verified system operation, and documented equipment condition with photos. All systems confirmed operational at time of service.
FL J.
FL J. Checked in
Completed preventive maintenance tune-up on 7-year-old residential HVAC system with indoor evaporator coil located in basement and outdoor condenser unit on patio. Performed standard inspection and service procedures on both components, verified system operation, and documented equipment condition with photos. All systems confirmed operational at time of service.
Northville, MI 48167
Responded to service call for multiple non-functioning outlets throughout the residence. Upon arrival, performed systematic electrical testing using digital voltage meter at affected outlet locations, including kitchen area with marble countertop and secondary location with horizontal panel siding. Testing revealed voltage irregularities, with readings of 122V and 102V respectively at different circuits. Diagnosed and resolved the electrical issue, restoring proper power to all affected outlets in the home.
Responded to service call for multiple non-functioning outlets throughout the residence. Upon arrival, performed systematic electrical testing using digital voltage meter at affected outlet locations, including kitchen area with marble countertop and secondary location with horizontal panel siding. Testing revealed voltage irregularities, with readings of 122V and 102V respectively at different circuits. Diagnosed and resolved the electrical issue, restoring proper power to all affected outlets in the home.
FL B.
FL B. Checked in
Responded to service call for multiple non-functioning outlets throughout the residence. Upon arrival, performed systematic electrical testing using digital voltage meter at affected outlet locations, including kitchen area with marble countertop and secondary location with horizontal panel siding. Testing revealed voltage irregularities, with readings of 122V and 102V respectively at different circuits. Diagnosed and resolved the electrical issue, restoring proper power to all affected outlets in the home.
Northville, MI 48167
Completed comprehensive Gold AC inspection on 16-year-old Bryant air conditioning unit located at residential property. Performed full system evaluation including refrigerant pressure checks, electrical component testing, condenser coil inspection, and fan motor operation verification. Unit found to be operating within normal parameters with no immediate service needs identified. Confirmed proper airflow through condenser coils and verified electrical connections at outdoor disconnect and power supply. Documented equipment condition with photographic records showing unit positioned on concrete pad with adequate clearance from surrounding landscaping and utility infrastructure.
Completed comprehensive Gold AC inspection on 16-year-old Bryant air conditioning unit located at residential property. Performed full system evaluation including refrigerant pressure checks, electrical component testing, condenser coil inspection, and fan motor operation verification. Unit found to be operating within normal parameters with no immediate service needs identified. Confirmed proper airflow through condenser coils and verified electrical connections at outdoor disconnect and power supply. Documented equipment condition with photographic records showing unit positioned on concrete pad with adequate clearance from surrounding landscaping and utility infrastructure.
FL W.
FL W. Checked in
Completed comprehensive Gold AC inspection on 16-year-old Bryant air conditioning unit located at residential property. Performed full system evaluation including refrigerant pressure checks, electrical component testing, condenser coil inspection, and fan motor operation verification. Unit found to be operating within normal parameters with no immediate service needs identified. Confirmed proper airflow through condenser coils and verified electrical connections at outdoor disconnect and power supply. Documented equipment condition with photographic records showing unit positioned on concrete pad with adequate clearance from surrounding landscaping and utility infrastructure.
Northville, MI 48167
Completed comprehensive Gold AC Inspection on a 7-year-old Bryant air conditioning system. Performed routine maintenance including visual inspection of outdoor condenser unit, checked refrigerant lines and electrical connections, verified proper operation of condenser fan, inspected coil fins for damage or debris accumulation, and documented system condition with photographs. Unit operational and in good working condition with no immediate repairs required.
Completed comprehensive Gold AC Inspection on a 7-year-old Bryant air conditioning system. Performed routine maintenance including visual inspection of outdoor condenser unit, checked refrigerant lines and electrical connections, verified proper operation of condenser fan, inspected coil fins for damage or debris accumulation, and documented system condition with photographs. Unit operational and in good working condition with no immediate repairs required.
FL M.
FL M. Checked in
Completed comprehensive Gold AC Inspection on a 7-year-old Bryant air conditioning system. Performed routine maintenance including visual inspection of outdoor condenser unit, checked refrigerant lines and electrical connections, verified proper operation of condenser fan, inspected coil fins for damage or debris accumulation, and documented system condition with photographs. Unit operational and in good working condition with no immediate repairs required.
Northville, MI 48168
Provided comprehensive estimate for replacement of 16-year-old air conditioning system experiencing compressor noise, outdoor fan motor drawing excessive amperage, and inadequate airflow around condenser unit. Evaluated existing Evolution system equipment and assessed compatibility with current furnace installation for complete system replacement recommendation.
Provided comprehensive estimate for replacement of 16-year-old air conditioning system experiencing compressor noise, outdoor fan motor drawing excessive amperage, and inadequate airflow around condenser unit. Evaluated existing Evolution system equipment and assessed compatibility with current furnace installation for complete system replacement recommendation.
FL S.
FL S. Checked in
Provided comprehensive estimate for replacement of 16-year-old air conditioning system experiencing compressor noise, outdoor fan motor drawing excessive amperage, and inadequate airflow around condenser unit. Evaluated existing Evolution system equipment and assessed compatibility with current furnace installation for complete system replacement recommendation.
Northville, MI 48168
Completed comprehensive Gold AC Inspection on a 4-year-old residential split system with two units and air handler located in basement. Performed full system evaluation of outdoor condenser unit including visual inspection of cabinet condition, refrigerant line insulation, electrical disconnect, and fan grille assembly. Noted debris accumulation on top grille and surrounding area with vegetation growth near unit base. Verified equipment operational status, documented system configuration, and captured photographic records of exterior condenser placement and condition. Recommended routine debris removal from top grille to maintain optimal airflow and system efficiency.
Completed comprehensive Gold AC Inspection on a 4-year-old residential split system with two units and air handler located in basement. Performed full system evaluation of outdoor condenser unit including visual inspection of cabinet condition, refrigerant line insulation, electrical disconnect, and fan grille assembly. Noted debris accumulation on top grille and surrounding area with vegetation growth near unit base. Verified equipment operational status, documented system configuration, and captured photographic records of exterior condenser placement and condition. Recommended routine debris removal from top grille to maintain optimal airflow and system efficiency.
FL P.
FL P. Checked in
Completed comprehensive Gold AC Inspection on a 4-year-old residential split system with two units and air handler located in basement. Performed full system evaluation of outdoor condenser unit including visual inspection of cabinet condition, refrigerant line insulation, electrical disconnect, and fan grille assembly. Noted debris accumulation on top grille and surrounding area with vegetation growth near unit base. Verified equipment operational status, documented system configuration, and captured photographic records of exterior condenser placement and condition. Recommended routine debris removal from top grille to maintain optimal airflow and system efficiency.
Northville, MI 48167
Completed comprehensive spring start-up inspection and preventive maintenance on 12-year-old residential air conditioning system as part of Gold maintenance plan. Performed complete AC tune-up including inspection of outdoor condensing unit, verified proper operation of all components, checked refrigerant levels, cleaned coils, and confirmed system is functioning properly with no issues identified. Unit is in good working condition and ready for the cooling season.
Completed comprehensive spring start-up inspection and preventive maintenance on 12-year-old residential air conditioning system as part of Gold maintenance plan. Performed complete AC tune-up including inspection of outdoor condensing unit, verified proper operation of all components, checked refrigerant levels, cleaned coils, and confirmed system is functioning properly with no issues identified. Unit is in good working condition and ready for the cooling season.
FL W.
FL W. Checked in
Completed comprehensive spring start-up inspection and preventive maintenance on 12-year-old residential air conditioning system as part of Gold maintenance plan. Performed complete AC tune-up including inspection of outdoor condensing unit, verified proper operation of all components, checked refrigerant levels, cleaned coils, and confirmed system is functioning properly with no issues identified. Unit is in good working condition and ready for the cooling season.
Northville, MI 48168
Replaced corroded anode rod on Performance Platinum water heater to restore corrosion protection and extend tank life. Performed complete tank flush to remove sediment buildup, improving heating efficiency and system performance.
Replaced corroded anode rod on Performance Platinum water heater to restore corrosion protection and extend tank life. Performed complete tank flush to remove sediment buildup, improving heating efficiency and system performance.
FL B.
FL B. Checked in
Replaced corroded anode rod on Performance Platinum water heater to restore corrosion protection and extend tank life. Performed complete tank flush to remove sediment buildup, improving heating efficiency and system performance.
Northville, MI 48167
Completed comprehensive tune-up and inspection on dual-zone HVAC system consisting of two air conditioning units and two furnaces installed in 2021. Performed combustion analysis using Testo 310 analyzer on both heating units, verified proper operation of all equipment, and conducted standard maintenance procedures on basement and exterior-mounted components. All systems tested and confirmed operational with no deficiencies noted.
Completed comprehensive tune-up and inspection on dual-zone HVAC system consisting of two air conditioning units and two furnaces installed in 2021. Performed combustion analysis using Testo 310 analyzer on both heating units, verified proper operation of all equipment, and conducted standard maintenance procedures on basement and exterior-mounted components. All systems tested and confirmed operational with no deficiencies noted.
FL M.
FL M. Checked in
Completed comprehensive tune-up and inspection on dual-zone HVAC system consisting of two air conditioning units and two furnaces installed in 2021. Performed combustion analysis using Testo 310 analyzer on both heating units, verified proper operation of all equipment, and conducted standard maintenance procedures on basement and exterior-mounted components. All systems tested and confirmed operational with no deficiencies noted.
Northville, MI 48167
financing-img
Heartland Academy Learn More

What To Expect

Discover the Difference
Satisfaction Guaranteed
Licensed & Insured Services
Upfront & Fair Pricing
Background Checked Technicians
Satisfaction Guaranteed
Licensed & Insured Services
Upfront & Fair Pricing
Background Checked Technicians
discover the difference
Review Image
Our Reviews

See What Your Neighbors Are Saying

When our old furnace quit working in mid-January we called FLAME to look at it. They came right out. They send a message or email when they are on their way to you. They did a great job and were very professional and tidy about their…

Poilin B.

Poilin B.

We contacted FLAME due to a gas leak at our church. It was very nice that they sent a text message with the technician’s name photo and estimated arrival time. I feel that they went above their service responsibilities by offering to work with the gas…

Danielle K.

Danielle K.

This is my first time experience and I am completely satisfied with the speed and courtesy of the company. I called the company I had been using for over 20 years to fix my central air and was given a date 8 days out...seriously?! One call…

Tina M.

Tina M.

Used this company twice, one for a same day gas line install for my dryer and then as a second opinion on an alleged leak and low refrigerant on my AC unit per another company. Turns out that there is no leak and the refrigerant levels…

Chris S.

Chris S.

I have had some bad experiences in the recent past with other contractors. FLAME has been a god send and are in the process of fixing all my issues at a reasonable price. I am a gold member and they have already installed and serviced my…

Sandra K.

Sandra K.

Hear What Our Customers Are Saying

Learn why so many choose FLAME Heating, Cooling, Plumbing & Electrical for all their HVAC, plumbing, and electrical needs.

When our old furnace quit working in mid-January we called FLAME to look at it. They came right out. They send a message or email when they are on their way to you. They did a great job and were very professional and tidy about their work. A great crew that worked well with each other.…

Poilin B.

Poilin B.

We contacted FLAME due to a gas leak at our church. It was very nice that they sent a text message with the technician’s name photo and estimated arrival time. I feel that they went above their service responsibilities by offering to work with the gas company to find the problem. Throughout this process we also…

Danielle K.

Danielle K.

This is my first time experience and I am completely satisfied with the speed and courtesy of the company. I called the company I had been using for over 20 years to fix my central air and was given a date 8 days out...seriously?! One call to FLAME and they had Jeff out within a few…

Tina M.

Tina M.

Used this company twice, one for a same day gas line install for my dryer and then as a second opinion on an alleged leak and low refrigerant on my AC unit per another company. Turns out that there is no leak and the refrigerant levels are fine. All of FLAME technicians that I have worked…

Chris S.

Chris S.

I have had some bad experiences in the recent past with other contractors. FLAME has been a god send and are in the process of fixing all my issues at a reasonable price. I am a gold member and they have already installed and serviced my furnace, AC and water heater. Thank you for always being…

Sandra K.

Sandra K.