The Charter Township of West Bloomfield is a beautiful community with a great view of nature at every turn and deserves only the best in heating and cooling.
That’s why FLAME Heating, Cooling, Plumbing & Electrical provides reliable repairs and installs only premium HVAC products for Oakland County residents. From energy-efficient gas furnaces to air conditioners and small package systems, you can rely on us for all your HVAC services in West Bloomfield, MI. Call today and learn about our highly efficient heating and cooling systems.
Efficient Furnace Installation and Repair Services
If you need a furnace repair or installation for your home or business, the HVAC technicians at FLAME have the skills to provide comprehensive services no matter the size of the project. From minor restorations to full installations, if you need fast and dependable services, we’re the team to call.
Furnace Installation
Get your property ready for the cold months with our expert furnace installation services for your Bloomfield, MI, property. Whether you need a gas or electricity furnace, FLAME will install the system with precision and care. With a furnace upgrade from us, you can enjoy better efficiency and consistently warm indoor temperatures and add to your property’s value.
Furnace Repair
If it’s time for a furnace repair, you can trust our team for expert services. A technician will examine the issue and discuss the best approach with you, keeping you informed of the project’s progress. We can repair blower motors, heating element issues, filter problems, and more. For quality furnace repair in Bloomfield, MI, call the experts at FLAME.
AC Repair and Installation in West Bloomfield Township
Your air conditioner is a valuable addition to your property, keeping you cool during the hot seasons. Whether you need an AC for a new build, want to replace your current one, or need a repair, we can handle it all. Get cooling services you can rely on for a comfortable home or business throughout the scorching summer months.
AC Installation
The quality of your AC installation can determine its longevity and performance. At FLAME, we provide thorough AC installations and replacements for a new cooling system that delivers consistent cool air. If you notice a spike in your energy bills, noise while the unit is on, refrigerant or water leaks, or any other issue, call us today for a durable installation.
AC Repair
A sudden AC breakdown can disrupt your day, which is why prompt services are vital. Once you contact us, we’ll visit your property to assess the issue and restore your AC system to proper function. Our technicians can repair:
Discover Why FLAME Is Different
At FLAME Heating, Cooling, Plumbing & Electrical, we’re proud to provide responsive and punctual support. See why residents choose us for heating and cooling services in Bloomfield:
- Transparent estimates and fair pricing
- Friendly and respectful services
- Easy financing options
- One-day installations
- Veteran, military and senior discounts
Book Heating and Cooling Services Today
Enjoy consistent indoor temperatures and improved reliability when you let our experts handle your HVAC needs. Call FLAME today at (586) 271-8813, or sign up online, and we’ll call you!
Recent Jobs and Reviews in West Bloomfield Township , MI
Job Locations and Reviews
Completed comprehensive Gold AC Inspection on dual 3-year-old residential air conditioning systems with air handler located in basement. Performed multi-point inspection on both outdoor condensing units, including visual assessment of cabinet condition, refrigerant line connections, electrical components, and fan operation. Both units showed normal weathering for age with functional operation confirmed; noted moderate dirt and grime accumulation on exterior casings typical of outdoor exposure. Verified refrigerant lines properly insulated and secured, checked manufacturer labels and specifications, and confirmed adequate clearance around equipment. Systems operating within normal parameters at time of inspection.
Completed comprehensive Gold AC Inspection on two outdoor air conditioning condenser units located at the property exterior. Performed thorough maintenance on both systems including inspection of condenser coils, fan motors, electrical connections, and refrigerant levels. Both units showed signs of age with weathered cabinets but were found to be in operational condition. Cleaned condenser coils on both units, verified proper airflow through louvers, tested capacitors and contactors, and ensured adequate clearance from surrounding vegetation. Checked electrical meter connections and verified proper voltage supply to both condensers. Inspected fan blades and motor assemblies for wear, lubricated moving components as needed, and confirmed proper fan operation on both units. All safety controls tested and functioning within normal parameters. Recommended ongoing seasonal maintenance to ensure continued reliable operation throughout cooling season.
Completed preventive maintenance tune-up on 6-year-old coil system located in basement. Performed comprehensive inspection of evaporator coil assembly, verified operational status of all components, and documented system conditions with thermal imaging and temperature differential measurements reading 88.8 degrees. All equipment found to be functioning properly with no immediate service needs identified.
Responded to a reported leak from an upstairs shower affecting the downstairs area. Upon investigation, accessed the plumbing system through the wall cavity and inspected the exposed piping, valve assembly, and connections serving the shower fixture. Identified the source of the leak, performed necessary repairs to the affected components, and verified proper operation of all shut-off valves and water lines to prevent future water intrusion.
Completed comprehensive Gold AC Inspection and tune-up on 9-year-old air conditioning system with basement-located air handler and exterior condenser unit. Performed full system evaluation including refrigerant level check, electrical component testing, condenser coil inspection and cleaning, blower motor assessment, and thermostat calibration verification. Exterior condenser unit showed normal wear with debris accumulation around base; cleared organic matter and wood chips from perimeter to ensure proper airflow and drainage. Inspected refrigerant lines and PVC condensate drain; all connections secure with no visible leaks detected. System operating within manufacturer specifications with adequate cooling capacity and proper cycling. Documented heavy rust and corrosion observed on water heater top connections during visual inspection of mechanical room, though this falls outside scope of AC maintenance service. All AC system components functioning properly with no immediate repairs re
Completed comprehensive Gold AC Inspection on a 30-year-old outdoor condensing unit. Performed standard maintenance procedures including system evaluation, component inspection, and operational testing. Inspection camera revealed significant internal corrosion and mineral buildup within system components, indicating advanced age-related deterioration that may require monitoring for future service needs.
Completed comprehensive tune-up and preventive maintenance on approximately 20-year-old residential air conditioning system with coil-type air handler located in basement. Performed full inspection of outdoor condenser unit, which showed signs of age-related wear and weathering but was operational. Verified proper electrical connections at disconnect box, inspected refrigerant lines, cleaned condenser coils, and assessed overall system performance to ensure efficient cooling operation for the upcoming season.
Completed comprehensive gold-level preventive maintenance on a 7-year-old Bryant outdoor condensing unit located at rear of condominium property. Performed full system inspection including electrical connections, refrigerant pressures, condenser coil cleaning, fan motor lubrication, capacitor testing, and thermostat calibration. Verified Aprilaire humidifier control operation and ductwork connections; all components found operating within manufacturer specifications with no deficiencies noted and system returned to optimal performance.
Responded to complaint of whistling noise from pump in master bathroom following recent water heater replacement. Upon inspection, identified recirculation pump generating excessive noise due to air in the system and improper pressure settings. Bled air from hot water lines at manifold connections and adjusted pump speed settings to eliminate cavitation. Verified proper operation of braided stainless steel flex lines, PEX supply connections, and pressure tank assembly. Confirmed all connections at the distribution manifold were secure and leak-free. Tested system operation through multiple cycles to ensure whistling noise was completely eliminated and water flow remained consistent throughout the home.
Performed leak search on residential HVAC system in response to customer concern. Conducted thorough inspection of Bryant furnace, associated ductwork, refrigerant lines, and condensate drainage system. Documented equipment condition and connections with photos for service records.
Completed routine maintenance tune-up on a 10-year-old Bryant air conditioning system with no reported issues. Performed comprehensive inspection of outdoor condensing unit, checked refrigerant levels, cleaned condenser coils, verified electrical connections, tested capacitor and contactor operation, and confirmed proper system operation. Unit found in serviceable condition with normal wear for age; all components functioning within manufacturer specifications.
Completed comprehensive Gold AC inspection on 3-year-old residential air conditioning system with outdoor condenser unit and air handler/coil located in small entrance attic. Performed thorough visual examination of condenser unit positioned on rubber pad in backyard, noting unit exterior condition, manufacturer specifications, and refrigerant line connections. Inspected evaporator coil fins for cleanliness and proper airflow, confirming no visible corrosion, damage, or debris accumulation on heat exchanger surfaces. Advised property owner that surrounding condenser area requires clearing of organic debris, leaves, and any animal waste to maintain optimal system performance and prevent airflow restriction.
Completed comprehensive Gold AC inspection on single-zone mini split system with air handler located in basement. Unit is one year old and operating properly at time of inspection. Performed standard maintenance protocol including visual inspection of all accessible components, verified proper operation of humidity control system (Aprilaire unit observed with appropriate seasonal settings), and documented equipment condition through photographic records. All systems functioning within normal parameters with no immediate service needs identified.
Completed comprehensive Gold-level air conditioning maintenance on a 12-year-old split system with outdoor condensing unit and indoor basement air handler. Performed full system inspection including refrigerant charge verification, electrical component testing, condenser coil cleaning, and airflow measurements. Replaced air filter per customer request and inspected humidifier pad as requested. All components operating within manufacturer specifications with no immediate service needs identified. System cleared for continued operation through cooling season.
Completed comprehensive Gold AC inspection on 4-year-old Daikin air conditioning system with air handler located in basement. Performed full system evaluation including refrigerant charge verification, electrical component testing, condenser coil cleaning, and operational performance assessment. Advised customer to maintain clear area around outdoor condenser unit, removing any debris and animal waste to ensure proper airflow and system efficiency.
Completed comprehensive Gold AC inspection on 4-year-old Lennox air conditioning system with indoor components located in basement and outdoor condensing unit positioned on concrete pad with gravel surround. Performed full system evaluation including refrigerant levels, electrical connections, contactor operation, capacitor testing, and airflow measurements. Verified proper operation of condensing unit with clean coils, functional fan motor, and adequate clearance from house exterior. System operating within manufacturer specifications with no deficiencies noted at time of inspection.
Completed comprehensive Gold AC Inspection on single residential air conditioning system with basement-located air handler. Outdoor condenser unit exhibited significant algae and biological growth on top surface and fan assembly, indicating extended exposure to moisture and requiring cleaning attention. Performed standard inspection protocol including visual assessment of equipment condition, electrical disconnect verification, and refrigerant line examination, with surrounding area showing moss accumulation and organic debris requiring maintenance consideration.
Completed routine tanked water heater flush and maintenance service. Drained sediment buildup from tank bottom, inspected anode rod condition, verified temperature and pressure relief valve operation, and tested all plumbing connections for leaks. System restored to proper operating condition with improved efficiency.
Completed Gold AC Inspection on a 2-year-old Bryant condensing unit located at the exterior of the residence with the air handler/coil situated in the basement. Performed comprehensive system evaluation including visual inspection of the outdoor condenser unit, verified proper operation of all components, and documented equipment condition through photographic records. Provided complimentary air filter to homeowner as part of scheduled maintenance visit.
Performed routine maintenance flush on tanked water heater located in basement of 20-year-old residential property. Unit was operating properly with no reported symptoms or performance issues at time of service. Drained sediment buildup from tank bottom through drain valve, flushed system with fresh water to remove accumulated mineral deposits and debris, and refilled tank to restore normal operation. Inspected unit for any signs of corrosion, leaks, or component wear during maintenance procedure. All connections, pressure relief valve, and temperature settings verified to be within normal operating parameters. Provided customer with information regarding tankless water heater options as requested for future consideration.