Heating and Cooling Services in West Bloomfield Township

The Charter Township of West Bloomfield is a beautiful community with a great view of nature at every turn and deserves only the best in heating and cooling.

That’s why FLAME Heating, Cooling, Plumbing & Electrical provides reliable repairs and installs only premium HVAC products for Oakland County residents. From energy-efficient gas furnaces to air conditioners and small package systems, you can rely on us for all your HVAC services in West Bloomfield, MI. Call today and learn about our highly efficient heating and cooling systems.

Efficient Furnace Installation and Repair Services

If you need a furnace repair or installation for your home or business, the HVAC technicians at FLAME have the skills to provide comprehensive services no matter the size of the project. From minor restorations to full installations, if you need fast and dependable services, we’re the team to call.

Furnace Installation

Get your property ready for the cold months with our expert furnace installation services for your Bloomfield, MI, property. Whether you need a gas or electricity furnace, FLAME will install the system with precision and care. With a furnace upgrade from us, you can enjoy better efficiency and consistently warm indoor temperatures and add to your property’s value.

Furnace Repair

If it’s time for a furnace repair, you can trust our team for expert services. A technician will examine the issue and discuss the best approach with you, keeping you informed of the project’s progress. We can repair blower motors, heating element issues, filter problems, and more. For quality furnace repair in Bloomfield, MI, call the experts at FLAME.

AC Repair and Installation in West Bloomfield Township

Your air conditioner is a valuable addition to your property, keeping you cool during the hot seasons. Whether you need an AC for a new build, want to replace your current one, or need a repair, we can handle it all. Get cooling services you can rely on for a comfortable home or business throughout the scorching summer months. 

AC Installation

The quality of your AC installation can determine its longevity and performance. At FLAME, we provide thorough AC installations and replacements for a new cooling system that delivers consistent cool air. If you notice a spike in your energy bills, noise while the unit is on, refrigerant or water leaks, or any other issue, call us today for a durable installation.

AC Repair

A sudden AC breakdown can disrupt your day, which is why prompt services are vital. Once you contact us, we’ll visit your property to assess the issue and restore your AC system to proper function. Our technicians can repair:

Discover Why FLAME Is Different

At FLAME Heating, Cooling, Plumbing & Electrical, we’re proud to provide responsive and punctual support. See why residents choose us for heating and cooling services in Bloomfield:

  • Transparent estimates and fair pricing
  • Friendly and respectful services
  • Easy financing options
  • One-day installations
  • Veteran, military and senior discounts

Book Heating and Cooling Services Today

Enjoy consistent indoor temperatures and improved reliability when you let our experts handle your HVAC needs. Call FLAME today at (586) 271-8813, or sign up online, and we’ll call you!

Recent Jobs and Reviews in West Bloomfield Township , MI

Job Locations and Reviews

Completed air conditioning system startup for newly installed basement evaporator coil. Verified proper refrigerant line connections, condensate drainage system operation with PVC piping and condensate pump, and confirmed all electrical connections to control components. System tested and operating within manufacturer specifications with adequate airflow and drainage functioning correctly.
Completed air conditioning system startup for newly installed basement evaporator coil. Verified proper refrigerant line connections, condensate drainage system operation with PVC piping and condensate pump, and confirmed all electrical connections to control components. System tested and operating within manufacturer specifications with adequate airflow and drainage functioning correctly.
FL P.
FL P. Checked in
Completed air conditioning system startup for newly installed basement evaporator coil. Verified proper refrigerant line connections, condensate drainage system operation with PVC piping and condensate pump, and confirmed all electrical connections to control components. System tested and operating within manufacturer specifications with adequate airflow and drainage functioning correctly.
West Bloomfield Township, MI 48324
Completed comprehensive Gold AC Inspection and tune-up on 2-year-old Lennox condenser unit. Performed full system diagnostics including refrigerant pressure checks, electrical component testing, capacitor readings, contactor inspection, and airflow verification. Cleaned condenser coils, checked drain line operation, verified proper thermostat operation, and inspected both outdoor unit and indoor air handler components. All systems operating within manufacturer specifications with no deficiencies noted.
Completed comprehensive Gold AC Inspection and tune-up on 2-year-old Lennox condenser unit. Performed full system diagnostics including refrigerant pressure checks, electrical component testing, capacitor readings, contactor inspection, and airflow verification. Cleaned condenser coils, checked drain line operation, verified proper thermostat operation, and inspected both outdoor unit and indoor air handler components. All systems operating within manufacturer specifications with no deficiencies noted.
FL S.
FL S. Checked in
Completed comprehensive Gold AC Inspection and tune-up on 2-year-old Lennox condenser unit. Performed full system diagnostics including refrigerant pressure checks, electrical component testing, capacitor readings, contactor inspection, and airflow verification. Cleaned condenser coils, checked drain line operation, verified proper thermostat operation, and inspected both outdoor unit and indoor air handler components. All systems operating within manufacturer specifications with no deficiencies noted.
West Bloomfield Township, MI 48323
Responded to service call for ductless mini-split system experiencing reduced cooling performance in living room/bedroom area. Performed comprehensive inspection of wall-mounted indoor unit and assessed system operation. Evaluated refrigerant levels, airflow, and overall system functionality to determine whether unit required recharging or replacement. Provided estimate for mini-split replacement options based on findings from diagnostic assessment.
Responded to service call for ductless mini-split system experiencing reduced cooling performance in living room/bedroom area. Performed comprehensive inspection of wall-mounted indoor unit and assessed system operation. Evaluated refrigerant levels, airflow, and overall system functionality to determine whether unit required recharging or replacement. Provided estimate for mini-split replacement options based on findings from diagnostic assessment.
FL S.
FL S. Checked in
Responded to service call for ductless mini-split system experiencing reduced cooling performance in living room/bedroom area. Performed comprehensive inspection of wall-mounted indoor unit and assessed system operation. Evaluated refrigerant levels, airflow, and overall system functionality to determine whether unit required recharging or replacement. Provided estimate for mini-split replacement options based on findings from diagnostic assessment.
West Bloomfield Township, MI 48322
Completed comprehensive Gold AC inspection on 10+ year old single unit system with basement-located air handler. Performed diagnostic testing using calibrated instruments, measuring system pressures at 106.8 psig low side and 157.2 psig high side on R-410A refrigerant. Evaluated system performance metrics including calculated superheat of 11.0°F (target 18.0°F) and subcooling of 8.1°F (target 16.0°F), indicating potential undercharge condition. Verified electrical parameters using True RMS multimeter, documenting amperage draw and voltage readings. System currently operational with homeowner present; documented all findings with diagnostic screenshots for service records.
Completed comprehensive Gold AC inspection on 10+ year old single unit system with basement-located air handler. Performed diagnostic testing using calibrated instruments, measuring system pressures at 106.8 psig low side and 157.2 psig high side on R-410A refrigerant. Evaluated system performance metrics including calculated superheat of 11.0°F (target 18.0°F) and subcooling of 8.1°F (target 16.0°F), indicating potential undercharge condition. Verified electrical parameters using True RMS multimeter, documenting amperage draw and voltage readings. System currently operational with homeowner present; documented all findings with diagnostic screenshots for service records.
FL W.
FL W. Checked in
Completed comprehensive Gold AC inspection on 10+ year old single unit system with basement-located air handler. Performed diagnostic testing using calibrated instruments, measuring system pressures at 106.8 psig low side and 157.2 psig high side on R-410A refrigerant. Evaluated system performance metrics including calculated superheat of 11.0°F (target 18.0°F) and subcooling of 8.1°F (target 16.0°F), indicating potential undercharge condition. Verified electrical parameters using True RMS multimeter, documenting amperage draw and voltage readings. System currently operational with homeowner present; documented all findings with diagnostic screenshots for service records.
West Bloomfield Township, MI 48322
Responded to complaint of low water level in main floor toilet that continued dropping with air bubbles present after customer returned from vacation. Inspected toilet tank and bowl assembly, identifying internal component malfunction causing water loss and air infiltration. Removed tank lid and examined flush valve, flapper assembly, and fill valve mechanism. Adjusted Fluidmaster fill valve settings and replaced defective red flapper valve that was allowing water to slowly leak from tank into bowl. Verified proper seal on flush valve seat and confirmed refill tube was properly positioned in overflow tube. Tested flush cycle multiple times to ensure proper water level restoration and elimination of air bubbles in bowl. Verified toilet now maintains consistent water level without further loss.
Responded to complaint of low water level in main floor toilet that continued dropping with air bubbles present after customer returned from vacation. Inspected toilet tank and bowl assembly, identifying internal component malfunction causing water loss and air infiltration. Removed tank lid and examined flush valve, flapper assembly, and fill valve mechanism. Adjusted Fluidmaster fill valve settings and replaced defective red flapper valve that was allowing water to slowly leak from tank into bowl. Verified proper seal on flush valve seat and confirmed refill tube was properly positioned in overflow tube. Tested flush cycle multiple times to ensure proper water level restoration and elimination of air bubbles in bowl. Verified toilet now maintains consistent water level without further loss.
FL S.
FL S. Checked in
Responded to complaint of low water level in main floor toilet that continued dropping with air bubbles present after customer returned from vacation. Inspected toilet tank and bowl assembly, identifying internal component malfunction causing water loss and air infiltration. Removed tank lid and examined flush valve, flapper assembly, and fill valve mechanism. Adjusted Fluidmaster fill valve settings and replaced defective red flapper valve that was allowing water to slowly leak from tank into bowl. Verified proper seal on flush valve seat and confirmed refill tube was properly positioned in overflow tube. Tested flush cycle multiple times to ensure proper water level restoration and elimination of air bubbles in bowl. Verified toilet now maintains consistent water level without further loss.
West Bloomfield Township, MI 48323
Completed kitchen sink plumbing repair involving the garbage disposal drain assembly and P-trap system beneath the cabinet. Inspected and serviced the connection points between the black disposal unit, white PVC P-trap, and flexible discharge hose to ensure proper drainage and eliminate leaks. Additionally, accessed the upper-level plumbing infrastructure to inspect and address copper supply line routing and support, verifying proper installation and securing of pipes within the floor joist system to prevent future issues.
Completed kitchen sink plumbing repair involving the garbage disposal drain assembly and P-trap system beneath the cabinet. Inspected and serviced the connection points between the black disposal unit, white PVC P-trap, and flexible discharge hose to ensure proper drainage and eliminate leaks. Additionally, accessed the upper-level plumbing infrastructure to inspect and address copper supply line routing and support, verifying proper installation and securing of pipes within the floor joist system to prevent future issues.
FL B.
FL B. Checked in
Completed kitchen sink plumbing repair involving the garbage disposal drain assembly and P-trap system beneath the cabinet. Inspected and serviced the connection points between the black disposal unit, white PVC P-trap, and flexible discharge hose to ensure proper drainage and eliminate leaks. Additionally, accessed the upper-level plumbing infrastructure to inspect and address copper supply line routing and support, verifying proper installation and securing of pipes within the floor joist system to prevent future issues.
West Bloomfield Township, MI 48324
West Bloomfield Township, MI - Completed comprehensive Gold AC inspection on 10+ year old single-unit residential air conditioning system with air handler located in basement. Performed thorough evaluation of outdoor condensing unit positioned on composite deck adjacent to home, noting weathered condition with surface discoloration, minor rust staining on top panel, and debris accumulation including leaves and organic matter. Inspected electrical conduit runs, refrigerant line sets, and mounting stability. System confirmed operational at time of inspection. Documented equipment condition through photographic record showing exterior unit wear consistent with age and environmental exposure, including moss growth on surrounding deck surface.
FL S.
FL S. Checked in
Completed comprehensive Gold AC inspection on 10+ year old single-unit residential air conditioning system with air handler located in basement. Performed thorough evaluation of outdoor condensing unit positioned on composite deck adjacent to home, noting weathered condition with surface discoloration, minor rust staining on top panel, and debris accumulation including leaves and organic matter. Inspected electrical conduit runs, refrigerant line sets, and mounting stability. System confirmed operational at time of inspection. Documented equipment condition through photographic record showing exterior unit wear consistent with age and environmental exposure, including moss growth on surrounding deck surface.
West Bloomfield Township, MI 48323
West Bloomfield Township, MI - Completed NSP AC inspection on single residential unit with air handler located in basement. Performed comprehensive system evaluation of outdoor condensing unit and associated components, verified proper refrigerant line installation and electrical connections, and documented equipment condition with photos. Unit found operating normally with no deficiencies noted during inspection.
FL S.
FL S. Checked in
Completed NSP AC inspection on single residential unit with air handler located in basement. Performed comprehensive system evaluation of outdoor condensing unit and associated components, verified proper refrigerant line installation and electrical connections, and documented equipment condition with photos. Unit found operating normally with no deficiencies noted during inspection.
West Bloomfield Township, MI 48322
Responded to service call for plumbing assessment beneath kitchen sink. Inspected dishwasher discharge line connection to garbage disposal unit and evaluated condition of shut-off valves serving sink supply lines. Examined under-sink plumbing configuration including P-trap assembly, disposal mounting, and water supply connections with braided stainless steel flex lines. Accessed crawlspace area to assess copper supply piping, support brackets, and overall condition of water distribution system serving kitchen fixtures. Documented existing plumbing infrastructure and identified components requiring replacement. Provided detailed evaluation and prepared replacement quotes for dishwasher connection line and aging shut-off valves as requested.
Responded to service call for plumbing assessment beneath kitchen sink. Inspected dishwasher discharge line connection to garbage disposal unit and evaluated condition of shut-off valves serving sink supply lines. Examined under-sink plumbing configuration including P-trap assembly, disposal mounting, and water supply connections with braided stainless steel flex lines. Accessed crawlspace area to assess copper supply piping, support brackets, and overall condition of water distribution system serving kitchen fixtures. Documented existing plumbing infrastructure and identified components requiring replacement. Provided detailed evaluation and prepared replacement quotes for dishwasher connection line and aging shut-off valves as requested.
FL B.
FL B. Checked in
Responded to service call for plumbing assessment beneath kitchen sink. Inspected dishwasher discharge line connection to garbage disposal unit and evaluated condition of shut-off valves serving sink supply lines. Examined under-sink plumbing configuration including P-trap assembly, disposal mounting, and water supply connections with braided stainless steel flex lines. Accessed crawlspace area to assess copper supply piping, support brackets, and overall condition of water distribution system serving kitchen fixtures. Documented existing plumbing infrastructure and identified components requiring replacement. Provided detailed evaluation and prepared replacement quotes for dishwasher connection line and aging shut-off valves as requested.
West Bloomfield Township, MI 48324
West Bloomfield Township, MI - Completed comprehensive Gold AC inspection on 10-year-old residential air conditioning system with air handler located in basement. Performed thorough evaluation of outdoor condenser unit, which showed normal weathering consistent with age, verified fan assembly and protective grille integrity, and assessed overall system condition. Documented equipment with photographic evidence showing condenser unit positioned against exterior brick wall with minor debris accumulation at base requiring routine maintenance attention.
FL S.
FL S. Checked in
Completed comprehensive Gold AC inspection on 10-year-old residential air conditioning system with air handler located in basement. Performed thorough evaluation of outdoor condenser unit, which showed normal weathering consistent with age, verified fan assembly and protective grille integrity, and assessed overall system condition. Documented equipment with photographic evidence showing condenser unit positioned against exterior brick wall with minor debris accumulation at base requiring routine maintenance attention.
West Bloomfield Township, MI 48322
Performed diagnostic evaluation on 16-year-old residential furnace located in basement presenting with system malfunction error at thermostat and no heat condition. Inspection revealed failing inducer motor assembly requiring replacement. Due to advanced age of equipment and repair costs relative to system value, provided comprehensive replacement estimate for new furnace installation. Documented existing HVAC infrastructure including ductwork configuration, electrical connections, and equipment access points to facilitate accurate replacement specifications and installation planning.
Performed diagnostic evaluation on 16-year-old residential furnace located in basement presenting with system malfunction error at thermostat and no heat condition. Inspection revealed failing inducer motor assembly requiring replacement. Due to advanced age of equipment and repair costs relative to system value, provided comprehensive replacement estimate for new furnace installation. Documented existing HVAC infrastructure including ductwork configuration, electrical connections, and equipment access points to facilitate accurate replacement specifications and installation planning.
FL S.
FL S. Checked in
Performed diagnostic evaluation on 16-year-old residential furnace located in basement presenting with system malfunction error at thermostat and no heat condition. Inspection revealed failing inducer motor assembly requiring replacement. Due to advanced age of equipment and repair costs relative to system value, provided comprehensive replacement estimate for new furnace installation. Documented existing HVAC infrastructure including ductwork configuration, electrical connections, and equipment access points to facilitate accurate replacement specifications and installation planning.
West Bloomfield Township, MI 48323
Responded to service call for non-operational Lennox furnace in basement mechanical room following water intrusion from recent plumbing leak. Performed complete system inspection of furnace, ductwork, and Emerson thermostat to assess water damage and verify operational status. Documented equipment condition with photographic evidence showing furnace, air handler, and associated components in utility room setting.
Responded to service call for non-operational Lennox furnace in basement mechanical room following water intrusion from recent plumbing leak. Performed complete system inspection of furnace, ductwork, and Emerson thermostat to assess water damage and verify operational status. Documented equipment condition with photographic evidence showing furnace, air handler, and associated components in utility room setting.
FL C.
FL C. Checked in
Responded to service call for non-operational Lennox furnace in basement mechanical room following water intrusion from recent plumbing leak. Performed complete system inspection of furnace, ductwork, and Emerson thermostat to assess water damage and verify operational status. Documented equipment condition with photographic evidence showing furnace, air handler, and associated components in utility room setting.
West Bloomfield Township, MI 48324
West Bloomfield Township, MI - Responded to no heat call with thermostat displaying system malfunction error on 8-year-old furnace located in basement. Upon arrival, performed diagnostic evaluation of heating system. Inspected gas furnace internal components including burner assembly, gas valve, and blower motor housing. Verified gas valve operation and observed burner flames igniting properly with characteristic blue flame pattern. Checked all electrical connections to gas valve including control wiring and safety circuits. Examined blower motor assembly and associated wiring harnesses for proper operation. Tested thermostat communication with furnace control board and cleared system malfunction code. Cycled system through multiple heating calls to confirm proper ignition sequence, flame sensing, and blower operation. Verified adequate airflow and proper temperature rise across heat exchanger. System restored to normal heating operation with all safety controls functioning as designed.
FL P.
FL P. Checked in
Responded to no heat call with thermostat displaying system malfunction error on 8-year-old furnace located in basement. Upon arrival, performed diagnostic evaluation of heating system. Inspected gas furnace internal components including burner assembly, gas valve, and blower motor housing. Verified gas valve operation and observed burner flames igniting properly with characteristic blue flame pattern. Checked all electrical connections to gas valve including control wiring and safety circuits. Examined blower motor assembly and associated wiring harnesses for proper operation. Tested thermostat communication with furnace control board and cleared system malfunction code. Cycled system through multiple heating calls to confirm proper ignition sequence, flame sensing, and blower operation. Verified adequate airflow and proper temperature rise across heat exchanger. System restored to normal heating operation with all safety controls functioning as designed.
West Bloomfield Township, MI 48323
West Bloomfield Township, MI - Completed comprehensive Gold AC inspection on 14-year-old residential cooling system with outdoor condenser unit and basement-located air handler. Performed full system evaluation including visual inspection of condenser cabinet, fan operation, electrical connections, and refrigerant lines. All components found operating within normal parameters with no immediate service needs identified at time of inspection.
FL S.
FL S. Checked in
Completed comprehensive Gold AC inspection on 14-year-old residential cooling system with outdoor condenser unit and basement-located air handler. Performed full system evaluation including visual inspection of condenser cabinet, fan operation, electrical connections, and refrigerant lines. All components found operating within normal parameters with no immediate service needs identified at time of inspection.
West Bloomfield Township, MI 48322
Responded to a slow leak in the basement of a 40-year-old residential property. Upon inspection of the crawl space, located the source of the leak in the copper supply line system running through the floor joists. The aging copper piping showed signs of corrosion and patina consistent with the home's age. Identified a compromised joint connection that had been slowly dripping for approximately 24 hours. Repaired the affected section by replacing the faulty fitting and securing all connections. Verified the integrity of surrounding copper pipes and PVC drainage lines. Tested the system for proper water pressure and confirmed no additional leaks were present. Documented the existing plumbing infrastructure with photographs for maintenance records. The repair was completed successfully with no further water intrusion detected.
Responded to a slow leak in the basement of a 40-year-old residential property. Upon inspection of the crawl space, located the source of the leak in the copper supply line system running through the floor joists. The aging copper piping showed signs of corrosion and patina consistent with the home's age. Identified a compromised joint connection that had been slowly dripping for approximately 24 hours. Repaired the affected section by replacing the faulty fitting and securing all connections. Verified the integrity of surrounding copper pipes and PVC drainage lines. Tested the system for proper water pressure and confirmed no additional leaks were present. Documented the existing plumbing infrastructure with photographs for maintenance records. The repair was completed successfully with no further water intrusion detected.
FL S.
FL S. Checked in
Responded to a slow leak in the basement of a 40-year-old residential property. Upon inspection of the crawl space, located the source of the leak in the copper supply line system running through the floor joists. The aging copper piping showed signs of corrosion and patina consistent with the home's age. Identified a compromised joint connection that had been slowly dripping for approximately 24 hours. Repaired the affected section by replacing the faulty fitting and securing all connections. Verified the integrity of surrounding copper pipes and PVC drainage lines. Tested the system for proper water pressure and confirmed no additional leaks were present. Documented the existing plumbing infrastructure with photographs for maintenance records. The repair was completed successfully with no further water intrusion detected.
West Bloomfield Township, MI 48322
Responded to active water leak in basement originating from area above Bradford White water heater. Upon inspection, identified moisture and condensation on metallic exhaust flue pipe extending from top of water heater unit. Leak had been present for several weeks with recent worsening, contained to immediate vicinity by floor drain. Examined all plumbing connections including copper supply lines with brass fittings and dielectric union, PVC discharge piping, and surrounding utility infrastructure including yellow condensate pump and associated drainage systems. Assessed water heater installation in 1973-era home with concrete block foundation. Documented conditions with photographic evidence showing wet flue pipe, plumbing configuration, and mechanical systems layout. Confined water damage to immediate area around water heater with proper drainage preventing spread throughout basement.
Responded to active water leak in basement originating from area above Bradford White water heater. Upon inspection, identified moisture and condensation on metallic exhaust flue pipe extending from top of water heater unit. Leak had been present for several weeks with recent worsening, contained to immediate vicinity by floor drain. Examined all plumbing connections including copper supply lines with brass fittings and dielectric union, PVC discharge piping, and surrounding utility infrastructure including yellow condensate pump and associated drainage systems. Assessed water heater installation in 1973-era home with concrete block foundation. Documented conditions with photographic evidence showing wet flue pipe, plumbing configuration, and mechanical systems layout. Confined water damage to immediate area around water heater with proper drainage preventing spread throughout basement.
FL B.
FL B. Checked in
Responded to active water leak in basement originating from area above Bradford White water heater. Upon inspection, identified moisture and condensation on metallic exhaust flue pipe extending from top of water heater unit. Leak had been present for several weeks with recent worsening, contained to immediate vicinity by floor drain. Examined all plumbing connections including copper supply lines with brass fittings and dielectric union, PVC discharge piping, and surrounding utility infrastructure including yellow condensate pump and associated drainage systems. Assessed water heater installation in 1973-era home with concrete block foundation. Documented conditions with photographic evidence showing wet flue pipe, plumbing configuration, and mechanical systems layout. Confined water damage to immediate area around water heater with proper drainage preventing spread throughout basement.
West Bloomfield Township, MI 48324
Completed installation of dual 50-gallon AO Smith power vent water heaters in basement utility room. Established all hot and cold water supply connections using copper piping with proper shut-off valves, installed PVC power vent exhaust systems for both units, and completed electrical connections to code. All plumbing connections were tested for leaks, units were energized and verified operational, and system was left fully functional with proper venting configuration.
Completed installation of dual 50-gallon AO Smith power vent water heaters in basement utility room. Established all hot and cold water supply connections using copper piping with proper shut-off valves, installed PVC power vent exhaust systems for both units, and completed electrical connections to code. All plumbing connections were tested for leaks, units were energized and verified operational, and system was left fully functional with proper venting configuration.
FL J.
FL J. Checked in
Completed installation of dual 50-gallon AO Smith power vent water heaters in basement utility room. Established all hot and cold water supply connections using copper piping with proper shut-off valves, installed PVC power vent exhaust systems for both units, and completed electrical connections to code. All plumbing connections were tested for leaks, units were energized and verified operational, and system was left fully functional with proper venting configuration.
West Bloomfield Township, MI 48322
Completed comprehensive Gold AC inspection and tune-up on residential R-410A air conditioning system as part of plan membership maintenance. Performed full system evaluation including inspection of dual outdoor condensing units, verified proper leveling and placement on concrete pads, checked electrical connections and components per manufacturer wiring diagram specifications, measured refrigerant operating pressures against factory charging chart, inspected condenser coils and fan operation, and documented equipment condition with photographic records. All systems found operating within normal parameters with no immediate repairs required.
Completed comprehensive Gold AC inspection and tune-up on residential R-410A air conditioning system as part of plan membership maintenance. Performed full system evaluation including inspection of dual outdoor condensing units, verified proper leveling and placement on concrete pads, checked electrical connections and components per manufacturer wiring diagram specifications, measured refrigerant operating pressures against factory charging chart, inspected condenser coils and fan operation, and documented equipment condition with photographic records. All systems found operating within normal parameters with no immediate repairs required.
FL K.
FL K. Checked in
Completed comprehensive Gold AC inspection and tune-up on residential R-410A air conditioning system as part of plan membership maintenance. Performed full system evaluation including inspection of dual outdoor condensing units, verified proper leveling and placement on concrete pads, checked electrical connections and components per manufacturer wiring diagram specifications, measured refrigerant operating pressures against factory charging chart, inspected condenser coils and fan operation, and documented equipment condition with photographic records. All systems found operating within normal parameters with no immediate repairs required.
West Bloomfield Township, MI 48322
Responded to service call for hallway light fixture that was inoperative following recent furnace installation. Investigated electrical circuit and determined that wiring had been inadvertently disconnected during HVAC work. Restored proper electrical connections to wall-mounted decorative light fixture, verified operation, and confirmed all circuits functioning correctly. Fixture now operating as intended with no further issues identified.
Responded to service call for hallway light fixture that was inoperative following recent furnace installation. Investigated electrical circuit and determined that wiring had been inadvertently disconnected during HVAC work. Restored proper electrical connections to wall-mounted decorative light fixture, verified operation, and confirmed all circuits functioning correctly. Fixture now operating as intended with no further issues identified.
FL S.
FL S. Checked in
Responded to service call for hallway light fixture that was inoperative following recent furnace installation. Investigated electrical circuit and determined that wiring had been inadvertently disconnected during HVAC work. Restored proper electrical connections to wall-mounted decorative light fixture, verified operation, and confirmed all circuits functioning correctly. Fixture now operating as intended with no further issues identified.
West Bloomfield Township, MI 48322
West Bloomfield Township, MI - Responded to service call for furnace malfunction. Upon arrival, performed diagnostic temperature testing at thermostat to verify system operation and temperature differential. Confirmed proper thermostat functionality and system response, restoring normal heating operation.
FL H.
FL H. Checked in
Responded to service call for furnace malfunction. Upon arrival, performed diagnostic temperature testing at thermostat to verify system operation and temperature differential. Confirmed proper thermostat functionality and system response, restoring normal heating operation.
West Bloomfield Township, MI 48322
financing-img
Heartland Academy Learn More

What To Expect

Discover the Difference
Satisfaction Guaranteed
Licensed & Insured Services
Upfront & Fair Pricing
Background Checked Technicians
Satisfaction Guaranteed
Licensed & Insured Services
Upfront & Fair Pricing
Background Checked Technicians
discover the difference
Review Image
Our Reviews

See What Your Neighbors Are Saying

When our old furnace quit working in mid-January we called FLAME to look at it. They came right out. They send a message or email when they are on their way to you. They did a great job and were very professional and tidy about their…

Poilin B.

Poilin B.

We contacted FLAME due to a gas leak at our church. It was very nice that they sent a text message with the technician’s name photo and estimated arrival time. I feel that they went above their service responsibilities by offering to work with the gas…

Danielle K.

Danielle K.

This is my first time experience and I am completely satisfied with the speed and courtesy of the company. I called the company I had been using for over 20 years to fix my central air and was given a date 8 days out...seriously?! One call…

Tina M.

Tina M.

Used this company twice, one for a same day gas line install for my dryer and then as a second opinion on an alleged leak and low refrigerant on my AC unit per another company. Turns out that there is no leak and the refrigerant levels…

Chris S.

Chris S.

I have had some bad experiences in the recent past with other contractors. FLAME has been a god send and are in the process of fixing all my issues at a reasonable price. I am a gold member and they have already installed and serviced my…

Sandra K.

Sandra K.

Hear What Our Customers Are Saying

Learn why so many choose FLAME Heating, Cooling, Plumbing & Electrical for all their HVAC, plumbing, and electrical needs.

When our old furnace quit working in mid-January we called FLAME to look at it. They came right out. They send a message or email when they are on their way to you. They did a great job and were very professional and tidy about their work. A great crew that worked well with each other.…

Poilin B.

Poilin B.

We contacted FLAME due to a gas leak at our church. It was very nice that they sent a text message with the technician’s name photo and estimated arrival time. I feel that they went above their service responsibilities by offering to work with the gas company to find the problem. Throughout this process we also…

Danielle K.

Danielle K.

This is my first time experience and I am completely satisfied with the speed and courtesy of the company. I called the company I had been using for over 20 years to fix my central air and was given a date 8 days out...seriously?! One call to FLAME and they had Jeff out within a few…

Tina M.

Tina M.

Used this company twice, one for a same day gas line install for my dryer and then as a second opinion on an alleged leak and low refrigerant on my AC unit per another company. Turns out that there is no leak and the refrigerant levels are fine. All of FLAME technicians that I have worked…

Chris S.

Chris S.

I have had some bad experiences in the recent past with other contractors. FLAME has been a god send and are in the process of fixing all my issues at a reasonable price. I am a gold member and they have already installed and serviced my furnace, AC and water heater. Thank you for always being…

Sandra K.

Sandra K.