Every Summer and Fall, Allen Park residents and visitors from all over Wayne County Michigan come to visit the Farmer’s Market. This fresh food market takes place right in downtown on Park Avenue between Harrison and McLain. It’s a staple for Allen Park, just like FLAME is an HVAC staple in the state of Michigan for over 67 years.
FLAME is proud to keep your home cozy all year long. With average temperatures reaching 16°F in the winter and 86°F in the summer, Allen Park residents expect nothing less than high quality and high efficiency products. After all, Allen Park was once recognized in Money Magazine’s list of America’s Best Small Cities. That is why FLAME technicians always performs thorough HVAC repairs and maintenance. And when it comes time for a new part or product, FLAME only installs high quality Bryant products.
So why choose FLAME for your Allen Park heating and cooling needs? Because we do high-quality HVAC work and install only the most reliable Bryant products, and it’s all backed by a 100% satisfaction guarantee.
Call us today or sign up online and we’ll call you!
(586) 217-2512
Recent Jobs and Reviews in Allen Park , MI
Allen Park, MI at a glance
Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Allen Park, MI between May 2026 and September 2026.
The most recent job was on September 26, 2026.
Flame Heating, Cooling, Plumbing, Electrical has completed 34 jobs in Allen Park, MI in the last 12 months.
Job Locations and Reviews
Completed on-site assessment for new whole home generator installation. Evaluated existing electrical service entrance with dual utility meters and main distribution panel, documented current 200-amp service configuration, and determined optimal generator placement and transfer switch requirements for seamless integration with existing electrical infrastructure.
Responded to service call for 1-year-old furnace in basement displaying thermostat error code 200 with only blower fan operating. Upon inspection, identified heavily soiled air filter restricting airflow and causing pressure switch fault. Replaced dirty filter with new filter, verified proper system operation including ignition sequence, gas valve function, and blower motor performance. System restored to normal heating operation with error code cleared and all components functioning within manufacturer specifications under parts and labor warranty.
Responded to no-cooling call on 3-year-old residential air conditioning system with basement evaporator coil. Upon arrival, confirmed unit was completely non-operational with no power to outdoor condensing unit. Inspected outdoor unit located along foundation and found excessive vegetation growth, debris accumulation, and obstructed airflow around condenser. Cleared weeds, grass, and organic matter from around unit perimeter. Verified electrical connections, tested capacitor, and checked refrigerant lines for damage. Restored power to system and confirmed proper startup sequence with compressor engaging and fan motor operating normally. Unit now cooling effectively with proper airflow restored.
Conducted on-site evaluation of existing SUN PURE under-sink water filtration system for replacement estimate. Assessed current dual-stage filter configuration with vertical cylindrical housings and horizontal mounting assembly, documented plumbing connections and cabinet space constraints. Photographed installation area including P-trap configuration, electrical connections, and cabinet condition to provide accurate replacement system specifications and labor requirements.
Completed comprehensive estimate for replacement of 10+ year old air conditioning and furnace system located in basement. Assessed existing HVAC equipment, documented current installation including white cabinet-style unit with associated PVC condensate drainage system, and evaluated infrastructure requirements for new system installation. Photographed equipment location, available workspace, existing ductwork connections, and utility access points to provide accurate replacement specifications and equipment recommendations.
Completed comprehensive Gold AC Inspection on aging outdoor condenser unit located at rear of property. Performed full system tune-up including cleaning of condenser coils, inspection of electrical connections and disconnect box, verification of refrigerant levels, testing of fan motor operation, and assessment of overall unit condition. Unit operational upon completion of maintenance service.
Responded to service call for AC system not cooling properly, with indoor temperature stuck at 77 degrees. Upon arrival, found system had previously experienced freezing issues with water pooling at furnace base. Performed diagnostic evaluation of 4-year-old outdoor condensing unit and indoor air handler. Verified thermostat operation and confirmed recent air filter replacement by homeowner. Documented system conditions with photos showing thermostat reading and indoor HVAC equipment setup. System had been allowed to thaw for two hours prior to arrival, with no active water accumulation present at time of inspection.
Completed comprehensive Gold AC Inspection on 2-year-old residential cooling system. Performed full tune-up on outdoor condenser unit, inspecting fan motor assembly, electrical connections, and refrigerant levels. Verified proper airflow through coil fins and checked compressor operation. Inspected indoor furnace blower motor and electrical wiring harnesses, confirming all connections secure and components operating within specifications. Cleaned condenser coils, checked voltage and amperage readings at both units, and tested thermostat communication. All systems found operating efficiently with no deficiencies noted. Unit showing normal wear consistent with age, with all safety controls functioning properly. Documented equipment condition with photos of both indoor furnace cabinet and outdoor condenser unit for maintenance records.
Completed installation of 2-ton air conditioning system with evaporator coil at rear location. Installed ML13KC1-024-230A03 condenser unit and CK4DCT-18/24A-71 evaporator coil, reconnected electrical service, and performed refrigerant charging and system startup. Verified proper system pressures, superheat, and subcooling readings using digital manifold gauges, confirming all operating parameters within manufacturer specifications. Installation completed per mechanical and electrical permits, with all equipment properly labeled and system operational.
Responded to warranty call for water leak on 10-month-old furnace located in basement. Upon inspection, discovered deteriorated and damaged foam insulation on condensate drain line allowing moisture accumulation. Replaced compromised insulation material and verified proper drainage from condensate system. Inspected blower assembly and internal components for water damage, confirmed no secondary issues present. Unit tested and operating within normal parameters with no further leakage detected.
Responded to service call for residential air conditioning system not cooling while fan continued to operate. Inspected 25-year-old outdoor condensing unit located in backyard against brick wall foundation. Upon evaluation of the aged system and current operating conditions, provided comprehensive replacement estimate for new HVAC equipment. Documented existing unit configuration, electrical connections, and indoor air handler installation in garage for proper system sizing and replacement planning.
Responded to no cooling call on 25-year-old air conditioning system with fan operation but no cooling affecting entire residence. Upon arrival, performed diagnostic testing of outdoor unit and indoor air handler components. Utilized digital multimeter to test electrical connections, capacitor values, and control board functionality at the air handler. Measured voltage readings at control board showing 27.1V on low voltage circuit. Inspected refrigerant lines, ductwork connections, and all electrical wiring at indoor unit. Documented equipment condition with photographs showing air handler installation, ductwork configuration, and diagnostic measurements. Based on age of system and diagnostic findings, provided customer with assessment of unit condition and repair options. System requires further evaluation of outdoor condensing unit components including compressor operation, capacitor condition, and refrigerant charge to determine root cause of cooling failure.
Responded to service call for newly installed photovoltaic system electrical issues causing repeated circuit tripping. Upon inspection, identified improper electrical installation in basement utility area where new PV system interconnection was affecting existing circuits. Traced electrical wiring through ceiling joists and verified proper conduit routing from basement to service panel. Corrected circuit protection issues, ensured proper grounding and bonding of electrical system, and verified all connections met NEC standards for PV installations. System tested and operational without further tripping incidents.
Completed comprehensive Gold AC inspection on 14-year-old residential air conditioning system with outdoor condenser unit and basement-located air handler. Performed full system evaluation including refrigerant levels, electrical connections, condenser coil cleaning, fan motor operation, thermostat functionality, and airflow assessment. All components found operating within normal parameters; system currently functioning properly with no immediate repairs required.
Installed new ice maker supply line from basement plumbing to refrigerator location. Routed flexible braided stainless steel water line through ceiling joists and connected to existing copper water supply system with appropriate fittings and shut-off valve for future service access.
Responded to service call for A.O. Smith ProMax tanked water heater with pilot light that would not remain lit. Inspected thermocouple, gas control valve, and pilot assembly for proper operation and connectivity. Cleaned pilot orifice, verified gas supply pressure, and tested flame sensor functionality to diagnose ignition system failure and restore reliable pilot operation.
Completed comprehensive Gold AC inspection on residential split system less than one year old with air handler located in basement and condenser unit positioned on concrete pad in backyard. Performed thorough visual examination of outdoor condensing unit, confirming fan grille in excellent condition with no damage or debris accumulation, proper clearances maintained around equipment, and unit operating as designed. All system components found to be functioning properly with no service issues identified during inspection.
Completed comprehensive Gold AC inspection on 5-year-old air conditioning system with air handler located in basement. Inspected outdoor condensing unit positioned on concrete pad against exterior brick wall, noting unit operational with proper electrical connections and refrigerant lines secured. Advised customer that debris including fallen leaves and twigs surrounding condenser unit should be cleared to maintain optimal airflow and system efficiency.
Provided comprehensive estimate for complete air conditioning system replacement due to non-functional 13-year-old unit with refrigerant leak. Assessed existing outdoor condenser unit, basement-mounted evaporator coil, electrical service panel, and natural gas furnace compatibility for new equipment installation. Documented current system configuration including electrical connections and outdoor unit placement to prepare detailed replacement proposal.
Completed removal and replacement of gas line to dryer in basement utility area. Existing gas line was disconnected and removed, and new gas line was installed and properly secured to supply dryer appliance. All connections were tested for leaks and verified operational upon completion.