Every Summer and Fall, Allen Park residents and visitors from all over Wayne County Michigan come to visit the Farmer’s Market. This fresh food market takes place right in downtown on Park Avenue between Harrison and McLain. It’s a staple for Allen Park, just like FLAME is an HVAC staple in the state of Michigan for over 67 years.
FLAME is proud to keep your home cozy all year long. With average temperatures reaching 16°F in the winter and 86°F in the summer, Allen Park residents expect nothing less than high quality and high efficiency products. After all, Allen Park was once recognized in Money Magazine’s list of America’s Best Small Cities. That is why FLAME technicians always performs thorough HVAC repairs and maintenance. And when it comes time for a new part or product, FLAME only installs high quality Bryant products.
So why choose FLAME for your Allen Park heating and cooling needs? Because we do high-quality HVAC work and install only the most reliable Bryant products, and it’s all backed by a 100% satisfaction guarantee.
Call us today or sign up online and we’ll call you!
(888) 234-2340
Recent Jobs and Reviews in Allen Park , MI
Job Locations and Reviews
Completed installation of 2-ton air conditioning system with evaporator coil at rear location. Installed ML13KC1-024-230A03 condenser unit and CK4DCT-18/24A-71 evaporator coil, reconnected electrical service, and performed refrigerant charging and system startup. Verified proper system pressures, superheat, and subcooling readings using digital manifold gauges, confirming all operating parameters within manufacturer specifications. Installation completed per mechanical and electrical permits, with all equipment properly labeled and system operational.
Responded to warranty call for water leak on 10-month-old furnace located in basement. Upon inspection, discovered deteriorated and damaged foam insulation on condensate drain line allowing moisture accumulation. Replaced compromised insulation material and verified proper drainage from condensate system. Inspected blower assembly and internal components for water damage, confirmed no secondary issues present. Unit tested and operating within normal parameters with no further leakage detected.
Responded to service call for residential air conditioning system not cooling while fan continued to operate. Inspected 25-year-old outdoor condensing unit located in backyard against brick wall foundation. Upon evaluation of the aged system and current operating conditions, provided comprehensive replacement estimate for new HVAC equipment. Documented existing unit configuration, electrical connections, and indoor air handler installation in garage for proper system sizing and replacement planning.
Responded to no cooling call on 25-year-old air conditioning system with fan operation but no cooling affecting entire residence. Upon arrival, performed diagnostic testing of outdoor unit and indoor air handler components. Utilized digital multimeter to test electrical connections, capacitor values, and control board functionality at the air handler. Measured voltage readings at control board showing 27.1V on low voltage circuit. Inspected refrigerant lines, ductwork connections, and all electrical wiring at indoor unit. Documented equipment condition with photographs showing air handler installation, ductwork configuration, and diagnostic measurements. Based on age of system and diagnostic findings, provided customer with assessment of unit condition and repair options. System requires further evaluation of outdoor condensing unit components including compressor operation, capacitor condition, and refrigerant charge to determine root cause of cooling failure.
Responded to service call for newly installed photovoltaic system electrical issues causing repeated circuit tripping. Upon inspection, identified improper electrical installation in basement utility area where new PV system interconnection was affecting existing circuits. Traced electrical wiring through ceiling joists and verified proper conduit routing from basement to service panel. Corrected circuit protection issues, ensured proper grounding and bonding of electrical system, and verified all connections met NEC standards for PV installations. System tested and operational without further tripping incidents.
Completed comprehensive Gold AC inspection on 14-year-old residential air conditioning system with outdoor condenser unit and basement-located air handler. Performed full system evaluation including refrigerant levels, electrical connections, condenser coil cleaning, fan motor operation, thermostat functionality, and airflow assessment. All components found operating within normal parameters; system currently functioning properly with no immediate repairs required.
Installed new ice maker supply line from basement plumbing to refrigerator location. Routed flexible braided stainless steel water line through ceiling joists and connected to existing copper water supply system with appropriate fittings and shut-off valve for future service access.
Responded to service call for A.O. Smith ProMax tanked water heater with pilot light that would not remain lit. Inspected thermocouple, gas control valve, and pilot assembly for proper operation and connectivity. Cleaned pilot orifice, verified gas supply pressure, and tested flame sensor functionality to diagnose ignition system failure and restore reliable pilot operation.
Completed comprehensive Gold AC inspection on residential split system less than one year old with air handler located in basement and condenser unit positioned on concrete pad in backyard. Performed thorough visual examination of outdoor condensing unit, confirming fan grille in excellent condition with no damage or debris accumulation, proper clearances maintained around equipment, and unit operating as designed. All system components found to be functioning properly with no service issues identified during inspection.
Completed comprehensive Gold AC inspection on 5-year-old air conditioning system with air handler located in basement. Inspected outdoor condensing unit positioned on concrete pad against exterior brick wall, noting unit operational with proper electrical connections and refrigerant lines secured. Advised customer that debris including fallen leaves and twigs surrounding condenser unit should be cleared to maintain optimal airflow and system efficiency.
Provided comprehensive estimate for complete air conditioning system replacement due to non-functional 13-year-old unit with refrigerant leak. Assessed existing outdoor condenser unit, basement-mounted evaporator coil, electrical service panel, and natural gas furnace compatibility for new equipment installation. Documented current system configuration including electrical connections and outdoor unit placement to prepare detailed replacement proposal.
Completed removal and replacement of gas line to dryer in basement utility area. Existing gas line was disconnected and removed, and new gas line was installed and properly secured to supply dryer appliance. All connections were tested for leaks and verified operational upon completion.
Completed comprehensive Gold AC inspection on 10+ year old single-unit air conditioning system with outdoor condenser and basement-located air handler. System was operational at time of service. Performed thorough visual inspection of outdoor condenser unit, verifying proper clearance from structure, secure mounting on concrete pad, and structural integrity of cabinet and protective grilles. Examined condenser coil fins for alignment, cleanliness, and airflow obstruction—coils appeared clean with properly aligned fins and no visible damage or deterioration. Inspected exterior housing for rust, corrosion, or weather damage; unit showed typical outdoor weathering with no significant concerns. Verified manufacturer labeling was intact and legible. Assessed overall equipment condition and confirmed unit remains in serviceable condition with no immediate repairs required. System continues to operate as designed.
Responded to service call for toilet not flushing properly. Upon arrival, inspected toilet mechanism and water flow system. Diagnosed and resolved flushing issue by adjusting internal flush valve components and verifying proper water level in tank, restoring full functionality to the toilet.
Completed commercial HVAC maintenance agreement service on single rooftop package unit. Performed routine inspection of RTU including visual assessment of cabinet condition, louvers, condenser fan assembly, and electrical disconnect. Unit found in normal operating condition with all components intact and functioning properly. Filters to be installed upon delivery to site.
Completed AC system start-up procedures for residential HVAC installation in basement mechanical room. Performed operational testing and verification of Evcon furnace unit with integrated Aprilaire whole-home humidifier system. Confirmed proper function of all components including venting configuration, ductwork connections, and humidifier water supply lines. System commissioned and running to manufacturer specifications.
Completed installation of new air conditioning system and evaporator coil in basement utility area, including furnace integration, condensate drainage lines with PVC piping, and ductwork modifications. Coordinated permit request and identified electrical work requirement for final system connection. Equipment remeasurement performed due to late specification changes to ensure proper sizing and fit.
Installed a GFCI receptacle on the exterior brick wall of the building. The outlet was properly mounted in a weatherproof protective cover with appropriate hardware to ensure code compliance and protection from the elements.
Completed comprehensive estimate for air conditioning system replacement and AC/media cabinet installation at residential property with existing 10-year-old furnace located in basement. Evaluated current outdoor condensing unit positioned along brick exterior foundation and assessed indoor thermostat controls currently set to heating mode at 70 degrees. Provided detailed replacement options and specifications for new AC system compatible with existing furnace infrastructure.
Completed Gold AC Inspection and tune-up on residential air conditioning system. Performed comprehensive maintenance including inspection of outdoor condenser unit, verified refrigerant levels, cleaned condenser coils, checked electrical connections and capacitor, tested thermostat operation, and confirmed proper system operation. Unit is operating within normal parameters with no issues identified at this time.