FLAME has a soft spot for small towns like Clawson, and FLAME offers big time deals on heating and cooling services for Clawson, Michigan residents. Let us take care of your home, so you can focus on all of the community events and entertainment opportunities offered in downtown Clawson and throughout the rest of Oakland County.
We’ll help you find the perfect, energy-efficient heating and cooling system for your home. It all starts with a free in-home consultation.
Clawson residents trust FLAME as the airflow pros at FLAME Heating, Cooling, Plumbing and Electrical of Michigan.
Call FLAME today, at (586) 217-2512, or sign up online, and we’ll call you!
Recent Jobs and Reviews in Clawson , MI
Clawson, MI at a glance
Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Clawson, MI between June 2026 and September 2026.
The most recent job was on September 30, 2026.
Flame Heating, Cooling, Plumbing, Electrical has completed 60 jobs in Clawson, MI in the last 12 months.
Job Locations and Reviews
Completed fall furnace tune-up on basement-located 5-year-old unit as part of Flame Fixed Membership plan maintenance. Performed comprehensive inspection including air filter evaluation, which showed minor discoloration but acceptable airflow capacity, and examined flame sensor component to ensure proper operation and connectivity. All systems tested and verified operational for the heating season.
Completed Gold Furnace Inspection on 4-year-old furnace system located in basement. Performed comprehensive inspection of all major heating components including burner assembly, heat exchanger, blower motor, and gas valve. Verified proper operation of ignition system and flame sensor. Inspected all electrical connections and wiring harnesses for secure connections and proper routing. Examined air filter condition and pleated media for airflow restriction. Checked humidifier system for proper operation and water supply. Tested thermostat functionality and calibration. Inspected hot water tank as part of comprehensive mechanical systems review. All safety controls and limit switches tested and confirmed operational. Burner flames observed burning blue with proper combustion characteristics. Blower motor operating smoothly without unusual noise or vibration. System cycling properly through all operational modes. No immediate safety concerns or repair needs identified at time of inspection
Completed comprehensive inspection and tune-up of steam boiler system installed in November 2022, located in basement. Inspected expansion tank, pressure gauge readings, copper piping connections, control valves, and associated ductwork for proper operation and safety compliance. All components found to be functioning within normal parameters with no immediate repairs required.
Completed comprehensive furnace inspection and tune-up on 6-year-old residential heating unit located in basement. Performed thorough visual examination of all internal components including blower motor assembly, draft inducer, heat exchanger, and electrical connections. Verified proper operation of all safety controls, checked gas connections and fittings for leaks, and inspected venting system for proper draft and clearances. All components found to be operating within manufacturer specifications with no immediate service needs identified. Unit is functioning properly and ready for heating season.
Completed comprehensive Gold Furnace Inspection on an 8-year-old forced air heating system located in basement. Performed thorough examination of all major components including gas valve assembly, burner tubes, blower motor, electrical connections, and wiring harnesses. Inspected gas line connections, verified proper operation of all safety controls, and documented equipment condition with detailed photography showing internal components and current system status. Unit is operating properly with all components functioning within normal parameters.
Responded to service call for gurgling noise coming from 2017 forced air furnace located in basement. Performed comprehensive inspection of heating system following previous repairs. Utilized Fieldpiece SC680 true RMS clamp meter to verify electrical readings and system performance. Measured incoming line voltage at 239 VAC, confirming proper power supply to unit. Tested amperage draw on system components, recording 10.2 amps during operation, which falls within normal operating parameters for equipment of this age and type. Inspected all accessible ductwork, condensate drainage system, and heat exchanger for potential sources of unusual sounds. Checked for proper condensate trap water level and drainage flow, as gurgling noises commonly originate from condensate system issues. Verified all electrical connections were secure and properly terminated. System operational at time of departure with no abnormal sounds detected during testing cycle.
Completed annual hot water boiler inspection and tune-up on a 1-year-old 96,000 BTU/h natural gas unit located in utility room. Verified operational status of control board with digital display reading 165°F, inspected all electrical connections and wiring harnesses, and examined gas valve assembly and manifold components. All safety controls, warning labels, and AHRI-certified specifications confirmed in proper working order with no deficiencies noted.
Completed prepaid maintenance inspection on a 2-year-old gas furnace located in basement. Performed comprehensive system evaluation including visual inspection of all internal components, blower motor assembly, heat exchanger, gas valve connections, venting system, and electrical wiring. All components found to be operating within normal parameters with no immediate service needs identified.
Completed comprehensive Gold-level furnace inspection on a 1-year-old forced air system located near the back door. Performed thorough examination of all furnace components including inducer fan motor, burner assembly, gas valve, ignition system, and electrical connections with all wiring harnesses verified for proper installation and function. Removed access panel to inspect internal components, confirmed proper operation of blower motor assembly, verified gas valve connections and all colored wire terminations secure, and documented equipment condition with photographic records. All burner tubes, safety controls, and ventilation components including flue pipe connections inspected and found to be operating within manufacturer specifications with no deficiencies noted at time of inspection.
Completed full electrical service upgrade including installation of new main electrical panel in basement utility area. Removed existing outdated service equipment and installed modern circuit breaker panel with proper load distribution across multiple branch circuits. Established new main breaker assembly with appropriate amperage rating, installed individual circuit breakers in organized configuration, and completed all necessary electrical connections using code-compliant wiring methods. Ensured proper grounding and bonding throughout the system, verified all circuits for correct operation, and confirmed safe installation in accordance with current electrical codes. System tested and operational.
Completed comprehensive Gold AC Inspection on a 1-year-old outdoor air conditioning system. Performed full system evaluation including visual inspection of condenser unit, verified proper operation of fan assembly and motor, checked electrical connections and disconnect, inspected refrigerant lines and housing for damage or deterioration, and confirmed unit is functioning correctly with no visible defects or maintenance concerns noted.
Responded to service call for central air conditioning system with reduced cooling capacity. Upon arrival, located Bryant brand condenser unit positioned against building exterior with overgrown vegetation restricting airflow around unit. Cleared debris and plant material from base and sides of condenser to restore proper ventilation and prevent efficiency loss. Performed electrical diagnostics using digital multimeter to verify system voltage, amperage draw, and component functionality. All electrical readings confirmed within manufacturer specifications with no detected abnormalities. Conducted thorough leak check of refrigerant system including condenser coil, service ports, and line connections - no leaks detected. System operating properly with adequate cooling output restored following vegetation clearance and diagnostic verification.
Completed comprehensive electrical inspection of residential basement electrical panel and associated wiring systems. Evaluated panel condition, circuit loading, wire routing through floor joists, and proper securing of conductors with appropriate fasteners. Assessed conduit connections, grounding systems, and overall code compliance of the electrical installation in the unfinished basement utility area.
Completed comprehensive Gold AC inspection on 6-year-old Daikin outdoor condenser unit located on exterior concrete pad. Performed full system evaluation including visual inspection of cabinet condition, refrigerant lines, electrical connections, and fan assembly. Unit found to be in clean, functional condition with no visible damage, deterioration, or immediate service concerns noted during inspection.
Responded to service call for non-operational air conditioning unit with reported unusual noise and visible wiring damage. Upon arrival, inspected 23-year-old outdoor condensing unit and identified severely deteriorated electrical connections with exposed and damaged wiring at the contactor assembly. Found evidence of arcing and heat damage at wire terminals, along with significant corrosion on metal components throughout the unit due to age and weather exposure. Documented hazardous electrical conditions with photographs showing frayed wires and compromised connections that posed safety risk. Unit was deemed unsafe for operation and customer was advised to shut down system immediately to prevent potential electrical fire or further equipment damage. Recommended complete electrical component replacement and full system evaluation given the age of the equipment and extent of deterioration observed.
Completed comprehensive Gold AC preventive maintenance inspection on a 4-year-old residential outdoor condensing unit. Performed full system evaluation including refrigerant pressure checks, electrical component testing, condenser coil cleaning, and verification of proper airflow through the top-mounted fan assembly. All components operating within manufacturer specifications with no deficiencies noted.
Completed prepaid maintenance inspection on 1-year-old Lennox residential air conditioning system. Performed comprehensive evaluation of outdoor condensing unit and indoor basement coil assembly. Unit found in excellent operational condition with no deficiencies noted at time of service.
Completed comprehensive Gold AC Inspection and tune-up on an 11-year-old outdoor air conditioning unit located in backyard. Performed full system evaluation including inspection of condenser unit, fan assembly, and protective grille which showed normal age-related wear with accumulated dirt and debris. Cleaned condenser coils, checked refrigerant levels, tested electrical connections, verified proper airflow through fan assembly, and ensured all components were operating within manufacturer specifications. Unit is functioning properly and ready for continued seasonal use.
Completed comprehensive Gold AC inspection on 2010 HVAC system with air handler located in basement. Performed thorough evaluation of all system components including ductwork, refrigerant lines, electrical connections, and condensate drainage system. Advised customer to maintain clear area around outdoor condenser unit, removing any debris and animal waste to ensure proper airflow and system efficiency.
Performed no-charge estimate for laundry room plumbing fixtures. Assessed existing valves and faucet configuration, documented current conditions with photos, and provided replacement recommendations for scheduling upcoming installation. Parts ordered and available for pickup under purchase order at supply house.