Ferndale, Michigan in Oakland County offers a diverse collection of amenities in its downtown area with a philosophy of shopping local. FLAME believes in local, too, and provides heating and cooling solutions quickly and efficiently for Ferndale families and residents.
FLAME has over 67 years of experience in heating and cooling and we are proud of the HVAC products we install. We are also proud to offer Ferndale residents a wide-variety of energy efficient furnaces, air conditioners and small package, so you’ll be able to find the perfect solution for your home and your budget. With average temperatures dipping as low as 27°F in the winter and as high as 74°F in the summer, Ferndale residents need heating and cooling they can rely on. Which is why they call FLAME with all of their HVAC needs.
Call us today and ask about our free in-home consultation!
(888) 234-2340
Recent Jobs and Reviews in Ferndale , MI
Job Locations and Reviews
Completed full HVAC system installation including 45,000 BTU furnace and 1.5 ton air conditioning unit with humidifier in rear yard location. Coordinated mechanical and electrical permits, submitted utility rebate applications to Consumers Energy and DTE, and verified AHRI certification number 217454512. Reconnected all gas, electrical, and refrigerant lines, with electrical work completed by licensed electrician as required.
Conducted site assessment for mini split installation in living room and primary bedroom of residence currently served by 21-year-old boiler with no existing cooling system. Evaluated exterior mounting locations, photographed potential condenser placement areas and existing electrical infrastructure including red conduit routing on exterior wall. Documented site conditions including foundation access points, siding configuration, and clearance requirements for outdoor unit installation to prepare comprehensive estimate for dual-zone ductless heat pump system.
Completed full HVAC system replacement in basement of small residential property (0-1500 sq.ft.). Removed existing equipment and installed new natural gas furnace with air handler unit and added new air conditioning system to provide complete heating and cooling capability. Configured ductwork connections including flexible and rigid components, routed refrigerant lines, and integrated system with existing infrastructure. All equipment mounted, leveled, and secured per manufacturer specifications with proper clearances maintained for service access and code compliance.
Completed comprehensive Gold AC Inspection on an 11-year-old air conditioning system with air handler/coil located in basement. System was operational at time of inspection. Advised customer that area surrounding outdoor condenser unit requires clearing of debris and animal waste, as litter boxes with waste were observed in close proximity to HVAC equipment. Performed complete system evaluation including visual inspection of ductwork, air handler components, and overall equipment condition. Customer was informed that weather conditions can affect inspection parameters, requiring rescheduling if temperatures fall below 65 degrees or during precipitation.
Responded to service call for leaking sight glass on boiler system. Replaced defective sight glass assembly with new unit, ensuring proper sealing and eliminating leak. Performed comprehensive boiler cleaning including removal of sediment buildup and inspection of all components. Verified system operation and confirmed all functions working properly upon completion.
Responded to service call for gas line evaluation in residential basement where four gas leaks had been previously identified. Performed comprehensive visual inspection of gas piping system throughout unfinished basement area, including exposed gas lines running along concrete block walls and connections near water heater and HVAC equipment. Conducted pressure test on gas distribution system to verify leak locations and assess overall system integrity. Documented existing gas line configuration, including black iron pipe routing, fittings, and connection points to appliances. Evaluated condition of gas piping infrastructure, noting age, installation methods, and accessibility for potential repair work. Photographed gas line installation and mechanical room layout for estimation purposes. Identified compromised sections of gas piping requiring attention to restore system to safe operating condition. Provided homeowner with detailed assessment of gas line system and discussed options for
Completed comprehensive Gold AC inspection on 2017 residential air conditioning system with air handler located on first floor. Performed full system evaluation including condenser unit inspection, which is positioned on concrete pad in exterior yard area; noted presence of wood chips, fallen leaves, and organic debris surrounding unit that should be cleared to maintain proper airflow and prevent potential equipment issues. Advised customer to maintain clear area around condenser and remove any debris or animal waste to ensure optimal system performance and longevity.
Completed installation of a 50-gallon standard tanked water heater in basement utility area. Installed new copper supply lines with proper compression fittings and valves, including boiler drain connections for future maintenance access. Performed miscellaneous plumbing repairs including securing exposed piping to ceiling joists with appropriate mounting brackets and straps. All connections were properly soldered and tested for leaks. System was commissioned and verified operational upon completion.
Completed comprehensive tune-up on 6-year-old gas furnace located in kitchen. Inspected burner assembly and confirmed proper ignition with clean blue flames and normal orange tipping on all four burners. Examined air filter which showed moderate dust accumulation and discoloration; noted filter condition for replacement consideration. Verified equipment operational status with all components functioning within normal parameters.
Completed comprehensive HVAC estimate for full system replacement at residential property. Assessed existing furnace and ductwork configuration in mechanical room, documenting current equipment specifications and measurements for proper sizing of new air conditioning system. Evaluated outdoor installation location at side of house near basement window well area, confirming adequate clearance and access for new condensing unit placement.
Conducted on-site assessment for water heater replacement, evaluating current 40-gallon tanked unit and determining appropriate capacity requirements for household demand. Inspected existing plumbing infrastructure including supply lines, shut-off valves, and venting system in basement utility area. Examined aging laundry sink valve assembly with corroded brass fixtures and deteriorating shut-off controls serving washing machine supply lines. Provided professional recommendations for upgrading to appropriately-sized tanked water heater unit and replacing worn laundry room plumbing valves to ensure reliable water supply and prevent potential leaks.
Completed comprehensive Gold AC inspection on 6-year-old Bryant residential air conditioning system. Performed full system evaluation including outdoor condenser unit positioned on concrete pad, verified proper electrical connections from disconnect box, inspected refrigerant lines and condensate drainage, examined indoor air handler located in basement, tested system operation and airflow, and confirmed unit is functioning properly with no immediate service needs identified. All components inspected and found to be in good working condition.
Performed scheduled commercial HVAC maintenance on one Carrier rooftop unit per maintenance agreement. Inspected air filters, which were found to be in clean condition with no excessive dust accumulation or damage. Completed routine system inspection and documentation with photographic records of unit condition and filter status.
Conducted comprehensive site assessment for full HVAC system replacement including central air conditioning installation, furnace replacement, and water heater replacement. Evaluated existing electrical panel capacity and circuit breaker configuration to ensure adequate power supply for new equipment installation. Inspected basement utility area including current furnace unit, ductwork routing, and available space for equipment placement. Documented existing infrastructure conditions including electrical wiring, structural supports, and mechanical room layout. Photographed electrical panel, existing HVAC equipment, and installation area to support estimate preparation for complete system upgrade.
Completed comprehensive estimate for full HVAC system replacement on 25-year-old furnace and air conditioning units located in basement and exterior of property. Primary concern identified was cracked heat exchanger in existing furnace, which poses safety hazard and requires immediate replacement. Conducted thorough inspection of both heating and cooling systems, evaluated humidifier functionality, assessed thermostat operation, and inspected hot water tank as part of complete system evaluation. Documented existing installation conditions including ductwork configuration, electrical panel connections, and equipment placement in unfinished basement utility area. Provided detailed replacement quote for new furnace and air conditioner system to address failed heat exchanger and aging equipment that has exceeded expected service life.
Responded to service call for furnace heating failure with pilot light cycling issues. Upon inspection, diagnosed intermittent ignition system malfunction preventing reliable heating operation while cooling function remained intact. Provided estimate for complete furnace replacement to resolve ongoing reliability concerns with the existing heating system.
Performed comprehensive tune-up and inspection on 25-year-old Lennox Elite Series furnace and air conditioning system. Conducted thorough examination of furnace cabinet, heat exchanger, burner assembly, and venting system including PVC intake and exhaust piping. Inspected pressure switch operation, condensate drain lines, and all safety controls. Verified proper airflow and replaced standard pleated air filter. Performed internal camera inspection of heat exchanger to assess for cracks or deterioration, documenting findings with endoscopic imaging. Evaluated thermostat operation and calibration. Inspected humidifier system for proper function and water supply. Checked hot water tank connections and venting. Examined outdoor condensing unit components including compressor, condenser coil, refrigerant lines, and electrical connections. All systems tested and operational at time of inspection.
Responded to service call for 8-month-old HVAC system where air conditioning unit required unplugging to allow furnace operation. Inspected basement-located evaporator coil and air handler electrical components. Diagnosed control board wiring conflict between heating and cooling systems causing operational interference. Verified all wire connections on control boards, checked refrigerant line connections, and inspected condensate pump with operational LED indicators. Resolved electrical control issue allowing simultaneous proper operation of both heating and cooling systems without requiring manual disconnection.
Responded to service call for unlevel condenser unit installed in 2024. Upon arrival, confirmed condenser was not properly leveled in backyard location. Repositioned and leveled condenser unit using precision leveling tools to ensure proper drainage and optimal compressor operation. Added 90-degree elbow fittings to refrigerant linesets to accommodate proper positioning and prevent stress on copper tubing connections. Verified unit stability and confirmed all refrigerant lines maintained proper pitch and support. System restored to manufacturer specifications for level installation.
Completed comprehensive Gold AC inspection on 3-year-old Lennox residential air conditioning system with outdoor condenser unit and basement-located air handler. Performed thorough visual inspection of condenser unit, verified proper fan operation, checked refrigerant levels, inspected electrical connections, cleaned condenser coils, and evaluated overall system performance. Unit found to be in excellent operating condition with no deficiencies noted; all components functioning within manufacturer specifications.