
FLAME is here to handle any heating and cooling needs you may have in your Riverview home. Our HVAC experts are highly trained in HVAC repairs and installation. And we use the highest quality products, so you know you’ll be getting the best money can buy.
If you need advice or aren’t sure what is the best choice to keep your Michigan home comfortable all year round, a FLAME expert is here to help. With a huge line of energy efficient products, FLAME can help you find the ideal heating and cooling solution for your home and your budget.
FLAME is proud to serve Riverview and Wayne County, Michigan residents with gas furnaces, air conditioners and any other HVAC product you may need. Riverview residents trust FLAME with over 70 years of industry experience.
Call FLAME today, at (586) 217-2512, or sign up online, and we’ll call you!
Recent Jobs and Reviews in Riverview , MI
Riverview, MI at a glance
Flame Heating, Cooling, Plumbing, Electrical has completed 17 jobs in Riverview, MI between February 2026 and September 2026.
The most recent job was on September 23, 2026.
Job Locations and Reviews
Completed comprehensive Gold-level furnace inspection on a 2-year-old forced air heating system located in the basement. Unit was operational at time of service. Performed thorough multi-point inspection including visual examination of heat exchanger, burner assembly, blower motor, and all electrical connections. Verified proper wiring configurations with red, white, yellow, and black conductor bundles routing to appropriate terminals. Inspected PVC condensate drain lines for proper drainage and secure connections. Evaluated cabinet interior components, control board functionality with illuminated indicators confirming normal operation, and assessed overall system condition. Documented equipment condition through photographic records showing interior components, wiring harness, and drainage system. All safety controls tested and verified operational. System operating within manufacturer specifications with no deficiencies noted.
Completed comprehensive Gold Furnace Inspection on 2025 model forced air unit located in basement. Performed electrical diagnostics using digital multimeter, recording capacitance reading of 50.05 MFD on system components. Installed 24V power connection to humidifier control board, integrating wiring into existing ECM drive circuit for proper operation. Verified all electrical connections, tested system functionality, and confirmed equipment operating within manufacturer specifications.
Completed comprehensive Gold AC inspection on 18-year-old residential cooling system with outdoor condenser unit and basement air handler. Performed full system diagnostics including refrigerant pressure testing, electrical component evaluation, condenser coil inspection, and airflow measurements. Also conducted furnace inspection per customer request to evaluate heating system performance and safety. All equipment currently operational with findings documented and photographed for maintenance records.
Responded to service call for reported pipe leaking at rear of furnace unit. Upon arrival, inspected 11+ year old furnace/AC system located in basement. Performed electrical diagnostics using multimeter to verify system operation and identify potential issues. Inspection revealed extensive rust and corrosion on ceiling surfaces above ductwork, indicating prolonged moisture exposure. Identified copper condensate drain line showing signs of oxidation and corrosion. Water staining visible on metal ductwork surfaces confirmed active or historical moisture infiltration. Documented equipment condition with detailed photographs showing electrical readings, corroded condensate piping, and rust damage to surrounding areas. System requires condensate drain line repair or replacement to resolve leaking issue and prevent further water damage to structure and HVAC components.
Responded to no-cooling call on 11-year-old residential AC system. Customer reported cold air blowing from outdoor condenser unit accompanied by grinding noise prior to shutdown. Upon arrival, performed diagnostic evaluation of split system with indoor air handler located in basement. Inspected thermostat operation, verified settings, and checked indoor unit components and ductwork connections. Based on customer description of outdoor unit symptoms including abnormal grinding noise and reversed airflow at condenser, identified likely compressor failure or severe mechanical issue with outdoor unit requiring further evaluation of condenser components. Recommended follow-up inspection of outdoor condenser unit to assess compressor condition, fan motor operation, and refrigerant system integrity to determine appropriate repair or replacement options for aging equipment.
Completed comprehensive spring start-up and preventative maintenance on 4-year-old residential air conditioning system with basement-mounted air handler and exterior condenser unit. Performed full system inspection including electrical connections, refrigerant line assessment, condenser coil cleaning, and operational testing to ensure optimal performance for the cooling season. All components found to be in good working condition with no deficiencies noted.
Completed comprehensive Gold Plan AC inspection on 10-year-old Bryant HVAC system with air handler located in basement. Verified system operational status and performed standard tune-up procedures including temperature diagnostics at outdoor condenser unit, recording 81.5°F ambient temperature reading. Inspected furnace cabinet, ductwork connections, venting system, and PVC condensate lines for proper installation and condition. Customer enrolled in Gold Plan maintenance agreement for both air conditioning and furnace systems to ensure continued preventative maintenance coverage.
Completed full HVAC system installation including a 70,000 BTU furnace rotated 90 degrees for proper fit, 2.5 ton air conditioning unit positioned in rear yard, chimney liner, and digital programmable thermostat. Installed S40 filter system with 4x25 media filter, reconnected gas and electrical connections, and set up condensate pump. Permit was requested and system tested successfully with thermostat cooling to target temperature of 70 degrees.
Conducted comprehensive on-site evaluation for complete HVAC system replacement, including existing furnace and air conditioning equipment. Assessed current outdoor condenser unit positioned against building exterior, documented equipment condition and installation parameters, and photographed electrical service connections and meter locations to determine compatibility requirements for new system installation. Provided detailed replacement options and specifications based on existing infrastructure and customer heating and cooling needs.
Responded to service call for thermostat malfunction where heating system operated normally but air conditioning would not activate. Conducted diagnostic assessment of 10+ year old AC system and existing thermostat of unknown age located in basement. Evaluated electrical panel configuration and circuit connections serving HVAC equipment. Inspected Carrier furnace unit and associated ductwork with seasonal damper controls in utility space. Documented existing equipment conditions and electrical service setup. Provided estimate for AC system replacement based on equipment age, operational failure of cooling function, and homeowner's service requirements.
Responded to service call for thermostat not activating air conditioning system while furnace operation remained functional. Upon inspection, found thermostat wiring configuration with multiple conductors present including Y1, Y2, G, OB, RC, W1, W2 AUX, C, and Rh terminals. Verified proper wire connections at thermostat base plate and traced wiring through attic space to air handler location. Identified cooling call circuit issue preventing compressor engagement. Corrected wiring connections at thermostat terminal block to restore proper communication between thermostat and 10+ year old air conditioning unit. Tested system operation through complete cooling cycle to confirm proper compressor startup and verified furnace heating function remained intact. System now operating correctly in both heating and cooling modes.
Completed comprehensive Gold AC inspection on 4-year-old residential air conditioning system with air handler/coil located in basement. Performed thorough visual inspection of outdoor condensing unit, verified proper placement on concrete pad, inspected refrigerant line connections and insulation integrity, and assessed overall system condition. Unit found in good operating condition with proper clearances maintained around condenser; advised customer to keep area clear of debris and animal waste for optimal performance and to ensure adequate airflow to system.
Replaced failed compressor on outdoor condensing unit. Recovered remaining refrigerant from system, removed and disposed of defective compressor, and installed new replacement compressor per manufacturer specifications. Pressure tested system for leaks, evacuated to proper vacuum levels, and recharged with correct refrigerant type and quantity. Verified system operation with proper amperage draw, suction and discharge pressures within normal range, and adequate temperature split across evaporator coil. System restored to full operational status.
Completed Gold AC Inspection on 13-year-old air conditioning system with basement-located air handler. Performed comprehensive electrical diagnostics using digital multimeter, measuring voltage and capacitance readings to verify proper system operation. All electrical components tested within normal operating parameters, with voltage reading of 379.9V and secondary measurement of 1007, confirming system is functioning correctly and ready for cooling season.
Completed comprehensive Gold AC inspection on 3-year-old Goodman residential cooling system with basement coil location. Performed thorough multi-point evaluation of outdoor condensing unit and indoor air handler components, verified proper system operation, checked refrigerant levels and pressures, inspected electrical connections, tested system performance parameters, and documented equipment condition with photographic records. All components found operating within manufacturer specifications with no immediate service requirements identified.
Responded to service call for air conditioning system not starting and short cycling after approximately 20 seconds of operation. Performed diagnostic inspection on Daikin split system installed in 2017, with condenser unit located at rear of residence. Testing revealed compressor shorted to ground, rendering outdoor unit inoperable. Discussed replacement options with homeowner, who requested estimate for condenser-only replacement while acknowledging potential compatibility considerations with existing indoor air handler. Documented system conditions and captured photographic evidence of outdoor condenser unit and indoor air handling equipment for estimate preparation purposes.
Responded to service call for multiple plumbing issues. Inspected kitchen sink and bathroom fixtures. Installed new sink stopper and tub stopper, addressed kitchen sink operational concerns, and replaced vacuum breaker on shower head and basement wash tub.