Keep your Farmington Hills home’s HVAC system up and running all year round, especially during the winter. At FLAME Heating, Cooling, Plumbing & Electrical, we aim to provide you with the expert heating and cooling solutions you deserve.
If you’re looking for reliable HVAC services in Farmington Hills, schedule a service with a technician or call 586-271-8813.
Reliable Furnace Installation and Repair
A furnace provides steady heat and is a convenient option. You can also choose an electric or gas furnace, whichever suits your needs. Whether you need furnace installation or repair in Farmington Hills, Michigan, our team will handle any service with attention to detail.
Furnace Installation
We’ll work with you to determine the right furnace type for your home and will install and connect it. Our thorough installation will prepare your household for the cold winters.
Furnace Maintenance and Repair
Furnace repair in Farmington Hills, Michigan, is an important service, and our team is ready to help with any issue. Whether your system is getting old or you’re noticing strange sounds or odors, we’ll identify the problem and apply the best solution.
We also install other types of heaters, including:
- Heat pumps
- Ductless mini-splits
- Packaged units
- Boilers and combination boilers
AC Repair and Installation Services
A summer’s day outside can be great, but only if you can return to a cool home. We specialize in virtually any type of AC system, providing comprehensive services you can count on. Let the team at FLAME Heating, Cooling, Plumbing & Electrical take care of your AC needs, including:
- AC installation: Our technicians will install your AC unit so it works efficiently and effectively. From central to ductless mini-split systems, we offer expert installation, readying you for the warmer months.
- AC repair and maintenance: If your air conditioner uses more energy than usual, is noisy, or isn’t cooling your home, it might be time for a repair. Rest assured, we’ll give the unit a new lease on life with comprehensive, targeted repairs.
See Why FLAME Heating, Cooling, Plumbing & Electrical Is Different
Whether you need a heater or AC repair in Farmington Hills, Michigan, you can trust our dedication to quality. We’ve been serving the community of Farmington Hills for over 75 years and continue to deliver exceptional services. When you choose us for your heating and cooling needs, you can enjoy:
- Prompt response times: We understand the urgency of an HVAC repair or installation and start the project swiftly.
- HVAC service experts: We specialize in all things HVAC, from heating to cooling and air quality. Our technicians are expertly trained and have the skills and experience to handle all your HVAC needs.
- Full-service company: Our comprehensive services include HVAC, plumbing, and electrical services.
- Financing options: Home care for HVAC, plumbing, and electrical needs isn’t cheap. That’s why we provide financing solutions and are upfront with our pricing to ensure we’re within your budget before you use our services. We even offer extensive discounts you can take advantage of immediately.
Schedule With FLAME Today
Our licensed and insured HVAC, plumbing, and electrical technicians at FLAME Heating, Cooling, Plumbing & Electrical have proudly served the Farmington Hills area since 1949. We strive to do the best job and treat your home and office as we would our own.
Contact FLAME for HVAC, plumbing, and electrical services by calling 586-271-8813.
Recent Jobs and Reviews in Farmington Hills , MI
Farmington Hills, MI at a glance
Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Farmington Hills, MI between August 2026 and September 2026.
The most recent job was on September 14, 2026.
Job Locations and Reviews
Completed comprehensive Gold Furnace Inspection on 3-year-old furnace unit located in basement. Performed full system diagnostics including visual inspection of all components, verified proper operation of blower motor and heat exchanger, checked gas connections and electrical systems, and confirmed all safety controls functioning within normal parameters. Inspected water heater plumbing connections during routine maintenance, noting visible corrosion on copper piping and darkening on pipe surfaces that may require future monitoring. Tested temperature differentials and system pressures, documenting return air dry bulb at 85.1°F and supply air readings at 133.6°F, indicating proper heat rise across the heat exchanger. Verified all mechanical connections secure, inspected ductwork for proper sealing, and confirmed blue shutoff valve operational. System operating efficiently with no immediate repairs required; all components within manufacturer specifications for equipment age.
Completed Gold Furnace Inspection on residential heating system located in basement. Unit has been in service for approximately 2 years and is currently operating within normal parameters. Performed comprehensive inspection of furnace components, verified proper system functionality, and documented equipment condition through photographic records. Noted significant water staining on concrete floor surrounding nearby water heater, indicating potential moisture concerns in the mechanical area that should be monitored. All furnace safety controls tested and confirmed operational. System airflow and combustion parameters verified to be within manufacturer specifications.
Responded to no cooling complaint on 8-year-old AC system located in basement. Upon inspection, discovered faulty electrical connections at junction box causing system failure. Repaired and secured all wiring connections, replaced damaged wire nuts, and verified proper voltage to unit. System tested and operational upon departure.
Responded to emergency service call regarding improper placement of backup generator exhaust in relation to makeup air intake system. Upon inspection, confirmed generator exhaust was positioned too close to makeup air intake, creating potential for carbon monoxide infiltration into the building. Documented existing installation with measurements and photographs showing generator placement approximately 3-4 feet from makeup air intake on exterior wall. Assessed code requirements and manufacturer specifications for proper clearances between combustion exhaust sources and fresh air intakes. Provided recommendations for remediation including either relocating generator unit to opposite side of structure, extending exhaust termination with approved piping to achieve minimum 10-foot separation, or relocating makeup air intake to alternate exterior wall location away from all combustion sources. Verified makeup air system and furnace are currently operational but advised system remain offline
Completed comprehensive whole home electrical inspection of residential property. Evaluated exterior electrical service components including weathered meter box, disconnect junction box, and associated conduit connections, as well as interior main electrical panel mounted in basement utility area. All visible electrical infrastructure, wiring, and panel components were examined for code compliance, safety concerns, and proper installation standards.
Conducted comprehensive site evaluation for full HVAC system replacement in 1800 square foot condominium unit. Assessed existing furnace installation, ductwork configuration, refrigerant line routing, and condensate drainage system. Documented current equipment condition showing age-related wear, copper pipe oxidation, and standard operational patina on existing components. Evaluated electrical supply, clearance requirements, and mechanical room accessibility for new equipment installation. Photographed existing system layout including furnace cabinet, galvanized ductwork assembly, PVC condensate piping with proper trap configuration, copper refrigerant lines, and utility connections to provide accurate specifications for replacement system proposal. Measured available installation space and confirmed proper ventilation access for future air conditioning and furnace equipment sizing recommendations.
Completed comprehensive Gold-level furnace inspection and tune-up on 10-year-old unit. Performed full system diagnostics including burner assembly cleaning, flame sensor maintenance, blower motor lubrication, air filter replacement, and flue pipe inspection with camera documentation showing proper venting and combustion chamber condition. All components operating within manufacturer specifications with no immediate repairs required; unit cleared for continued operation through the heating season.
Installed gas shutoff valve on existing gas line to accommodate dryer installation. Accessed gas line in basement area, cut into existing black iron pipe, and installed quarter-turn ball valve with appropriate fittings to provide isolation capability for appliance connection. Tested installation for leaks using approved methods and verified proper operation of shutoff mechanism.
Completed comprehensive tune-up inspection on 15-year-old furnace system located in crawlspace. Performed thorough evaluation of all mechanical and electrical components including burner assembly, heat exchanger, blower motor, gas valve, and control board. Inspected thermostat operation, humidifier functionality, and hot water tank condition as part of standard maintenance protocol. Identified failed inducer motor assembly requiring replacement. Ordered inducer motor assembly through Carrier Great Lakes with pickup scheduled at Livonia location. Unit tagged and customer advised of pending part arrival and installation. Documented all findings with photographic evidence showing internal component condition, wiring connections, and motor assembly. System operational status communicated to customer with callback number confirmed for scheduling return visit upon part receipt.
Completed comprehensive Gold Furnace Inspection on 10-year-old furnace system located in basement. Performed full system evaluation including inspection of Honeywell Ultraviolet Treatment System with dual controls and indicator lights, verified proper operation of UV bulb assembly and reviewed bulb replacement access procedures. Examined HVAC components including ductwork connections, protective grilles, and associated refrigeration equipment. All systems found operating within normal parameters with no immediate service requirements identified.
Completed comprehensive furnace inspection and tune-up on 16-year-old unit located in basement storage room. Removed and cleaned heavily soiled aluminum mesh filters showing significant grease and dust accumulation, restoring proper airflow. Inspected evaporative cooler assembly in attic space, noting considerable mineral deposits and debris buildup on honeycomb cooling pad. Verified motor assembly, electrical connections, and ductwork connections for proper operation. System operational upon completion with improved air filtration efficiency.
Successfully installed a 90,000 BTU high-efficiency furnace with humidifier and thermostat in basement utility area. Completed all electrical reconnections, installed new circuit breaker panel connections, and integrated humidification system with existing ductwork. Mechanical permit obtained and all work performed to code specifications, with unit qualifying for utility energy rebate program.
Completed annual cooling maintenance and AC tune-up on a 9-year-old Bryant system. Performed comprehensive inspection of outdoor condenser unit, verified proper system operation, checked refrigerant levels, cleaned components, and tested all safety controls. System found to be functioning properly with no deficiencies noted.
Performed comprehensive inspection on 4-year-old mini split system located behind garage. Conducted thorough evaluation of mini split unit, humidifier, thermostat, and hot water tank as requested. Identified heavily soiled air filters requiring immediate replacement due to significant dust and debris accumulation that could restrict airflow and reduce system efficiency.
Completed comprehensive Gold level seasonal maintenance on a 10-year-old residential boiler system in basement location. Performed full system tune-up including inspection of all major components, burner assembly, heat exchanger, and flue venting. Verified proper operation of combustion air intake and exhaust ventilation through galvanized vent piping. Inspected and tested expansion tank mounting and pressure settings. Examined all copper and brass supply and return piping connections for leaks or deterioration, noting insulation condition on hot water lines. Tested thermostat functionality and verified proper communication between control system and boiler unit. Checked gas connections, electrical components, and safety controls. Measured and documented operating pressures and temperatures to ensure system is performing within manufacturer specifications. Cleaned burner components and adjusted for optimal combustion efficiency. Verified proper condensate drainage and inspected all vis
Performed comprehensive tune-up on 2021 furnace located in basement utility room. Conducted full combustion analysis using calibrated diagnostic equipment, confirming natural gas system operating within manufacturer specifications with stack temperature at 391°F, CO2 at 7.1%, excess air at 58.4%, and carbon monoxide readings at safe levels. Inspected burner assembly, heat exchanger, blower motor, and ductwork connections; verified all components functioning properly with no safety concerns identified.
Responded to master bathroom plumbing issues involving stem leaks at stall shower and two vanity sink faucets, along with a leaking showerhead. Disassembled the three-piece chrome faucet assemblies on both undermount sink installations with granite countertops, replacing worn stem cartridges and seals to eliminate water seepage at the handles. Serviced the stall shower valve stems and replaced the showerhead to resolve dripping issue. Tested all fixtures under full water pressure to verify proper operation and confirmed no leaks at stems or spout connections upon completion.
Completed comprehensive whole home plumbing inspection for new homeowner. Inspected all accessible plumbing fixtures, supply lines, drain assemblies, and shut-off valves throughout the residence. Identified non-functional drain stopper mechanism in bathroom sink and noted excessive noise during bathtub water flow, likely caused by inadequate venting or drain line restrictions. Documented bathroom plumbing configuration including under-sink P-trap assembly with plastic tailpiece and PVC connections, braided stainless steel supply lines, and toilet water supply with brass angle stop valve. Observed evidence of previous water exposure on bathroom flooring near toilet shut-off valve area with visible staining on travertine tile surface, indicating potential historical leak or condensation issue. Photographed relevant plumbing components for documentation and customer reference. Provided detailed quote for necessary repairs including drain stopper replacement and investigation of bathtub dr
Completed comprehensive evaluation of 25-year-old furnace and humidifier system located in basement. Performed thorough inspection of HVAC equipment, humidifier, thermostat, and hot water tank as requested. Provided detailed replacement estimate for aging system, documented existing ductwork measurements and current equipment condition with photographic evidence for customer review.
Responded to service call for leaking kitchen faucet. Inspected brushed nickel pull-down faucet mounted on granite countertop with stainless steel undermount sink. Identified source of leak and performed necessary repairs to stop water dripping. Tested faucet operation to ensure proper function and confirmed no further leakage present.