With average temperatures in Grosse Pointe reaching lows of around 16 degrees Fahrenheit in the winter and highs of around 77 degrees Fahrenheit in the summer, you want to ensure you and your family remain warm or cool all year round.
The team at FLAME Heating, Cooling, Plumbing & Electrical can take care of all your heating and cooling in Grosse Point and surrounding areas. As your go-to HVAC provider in Michigan, we can help keep your home comfortable in all seasons.
Furnace Repair and Installation in Grosse Point
Furnaces keep your home warm even in the coldest months, and we can work with any brand or model. We provide the following furnace services:
- Furnace installation: Our technicians can install an electric or gas furnace and will do all the checks to make sure it’s running smoothly.
- Furnace maintenance and repair: If you notice your furnace is acting unusually and not providing enough heat, our team can help. We’ll inspect the unit and complete the required repairs.
Other types of heaters we install include:
- Combination boilers
- Boilers
- Heat pumps
- Ductless mini-splits
- Packaged units
AC Repair and Installation
Whether you want a ductless mini-split system or another air conditioning unit, FLAME Heating, Cooling, Plumbing & Electrical has the solutions to keep you cool and comfortable during the hot months. Our AC services include:
- AC installation: No project is too big or small for us. We’ll install the AC unit, set up the connections, and run the tests. Rest assured of comprehensive assistance when you choose us.
- AC maintenance and repair: If you’re looking for AC repair services in Grosse Pointe, you have come to the right place. As soon as you schedule a service with us, our technicians will drive to your home and restore your AC so it’s working as usual again.
Why Work With FLAME Heating, Cooling, Plumbing & Electrical?
Our team goes above and beyond, using quality tools, brands, and the latest industry technology to upgrade or repair your HVAC system. Our goal is for you to be comfortable in your living spaces and happy with your unit, which is why we provide the highest quality products and services.
Trusted HVAC Services
We only employ skilled and experienced HVAC technicians, allowing us to offer premium HVAC services in Grosse Point.
Fast Response in the Local Area
At FLAME Heating, Cooling, Plumbing & Electrical, we respect your time and want to install or repair your system as quickly as possible. That’s why we respond fast to your Grosse Pointe HVAC needs.
Competitive, Transparent Pricing
Get value for your money and budget with ease with our reasonable, transparent prices.
Contact Us Today for Reliable Heating and Cooling Services
Get started and schedule your appointment by calling us at 586-271-8813 or contacting us online.
Recent Jobs and Reviews in Grosse Pointe , MI
Grosse Pointe, MI at a glance
Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Grosse Pointe, MI between August 2026 and September 2026.
The most recent job was on September 29, 2026.
Flame Heating, Cooling, Plumbing, Electrical has completed 172 jobs in Grosse Pointe, MI in the last 12 months.
Job Locations and Reviews
Responded to a drain service call for a second floor bathroom with a clogged bathtub drain and clogged sink. Upon arrival, assessed both fixtures and determined blockages were preventing proper drainage. Successfully cleared both obstructions using appropriate drain cleaning equipment and techniques. Tested water flow in both the bathtub and sink to verify proper drainage was restored. All fixtures returned to normal operation upon completion.
Responded to A03 error code on basement thermostat. Performed diagnostic inspection of HVAC system including furnace components, gas valve assembly, inducer motor, and blower motors. Verified all electrical connections, wiring harness integrity, and control board functionality. Documented system condition with photos showing internal furnace components and thermostat display reading 35 degrees. All mechanical and electrical components found operating within normal parameters.
Completed comprehensive Gold Furnace Inspection and tune-up on two 1-year-old furnace units located in basement. Performed full system diagnostics on both units including visual inspection of burner assemblies, heat exchangers, and combustion chambers. Verified proper ignition sequence and observed clean, even blue flame pattern across all burner ports indicating optimal gas-air mixture and efficient combustion. Inspected and tested gas valve operation, electrical connections, and safety controls on both systems. Checked all mechanical components, blower assemblies, and ductwork connections. Confirmed proper venting and airflow throughout both systems. Both furnaces operating within manufacturer specifications with no deficiencies noted. All safety systems tested and functioning correctly. Units require no repairs at this time and are ready for continued reliable operation.
Completed comprehensive HVAC system inspection on 10-year-old heating unit located in basement, including evaluation of furnace operation, ductwork connections, and associated mechanical components. Performed thorough assessment of humidifier functionality, thermostat calibration and operation, and hot water tank condition. Documented existing equipment configuration including blue heating unit with metal ductwork, condensate drainage system, electrical connections, and plumbing interfaces to ensure all systems were operating within manufacturer specifications and safety standards.
Completed comprehensive Gold level boiler inspection on 16-year-old unit located in basement. Performed visual examination of burner assembly, heat exchanger, and internal components, documenting condition with photographs showing operational burners with minor surface wear and accumulated dust on reflective panels. All burners firing properly with no immediate safety concerns identified; recommended routine cleaning and continued monitoring due to age of equipment.
Completed Gold Furnace Inspection and routine maintenance on 5-year-old gas furnace located in basement. Performed filter replacement, verified burner operation with all burners igniting properly and producing clean blue flames, inspected heat exchanger for cracks or damage, and confirmed all system components functioning within normal parameters. No deficiencies or safety concerns identified during inspection.
Completed comprehensive Gold Boiler Inspection and fall maintenance tune-up on a 2-year-old residential boiler system located in basement. Performed full system evaluation including visual inspection of heat exchanger, burner assembly, and all safety controls. Verified proper operation of all components, checked venting system integrity, and confirmed water heater connections. System found in excellent condition with no issues identified; unit currently in off-season standby mode and ready for heating season operation.
Completed comprehensive Gold AC Inspection and preventive maintenance on a 1.5-2 year old air conditioning system and heating furnace located in basement. Performed full system diagnostics, inspected all internal components including blower motor assembly, electrical connections, gas lines, and refrigerant lines. Verified proper operation of all mechanical and electrical systems, checked wire terminations and connections, examined PVC intake and exhaust venting, and confirmed all safety controls functioning correctly. No issues found; system operating within normal parameters.
Completed boiler skim and startup procedure following new installation. Removed manufacturing oils and debris from boiler system through skimming process, flushed system to ensure clean operation, and performed comprehensive startup checks including burner ignition, flame sensor verification, and control sequence testing. Confirmed proper venting operation, verified all electrical connections within control panel, and validated system pressurization and water flow throughout the heating loop.
Performed comprehensive Gold-level boiler inspection on 13-year-old unit located in basement. Conducted combustion analysis using digital diagnostic meter, recording oxygen levels at 11.8%, efficiency rating of 23 EDF, and flue gas temperature of 298.9°F. All system parameters were within acceptable operating ranges, and equipment was found to be functioning properly at time of inspection.
Completed three-day boiler replacement installation including mechanical, electrical, and boiler permits with reconnection services. Installed new boiler system with automatic blowoff assembly, connected all supply and return piping, integrated PVC venting and drainage components, and verified proper operation of all controls and safety devices. All work performed to code with permits obtained and system commissioned successfully.
Conducted estimate for replacement of 10+ year old Spacepack system with attic-mounted natural gas furnace. Current equipment operational but aging, with visible dust accumulation on interior vent grilles and flexible ductwork in attic space. Documented existing installation including flexible duct routing, insulation condition, and equipment accessibility for replacement planning.
Completed comprehensive tune-up inspection on multi-zone HVAC system including gas furnace with Trion HE 1400 air handler located in basement, with additional units in backyard and second floor. Performed thorough inspection of all accessible components including burner assembly, heat exchanger, blower motor, gas lines, electrical connections, humidifier, thermostat, and hot water tank. All systems checked for proper operation and safety compliance.
Responded to service call for insufficient hot water production from tanked water heater system. Accessed basement utility room through tenant units to inspect dual A.O. Smith water heater installation consisting of units #2 and #3. Performed diagnostic evaluation of both tanked water heaters, examining gas control valves, copper supply and distribution piping, shut-off valves, and overall system configuration. Inspected manufacturer labels, safety warnings, and operational specifications on both units. Assessed piping connections, joints, elbows, and valve assemblies for proper function. Evaluated gas supply system and burner operation to determine cause of inadequate heating capacity. Documented existing installation condition including copper piping patina, insulated pipe runs, and dual-unit configuration designed for high-capacity residential hot water demand.
Completed comprehensive Gold membership inspection on 8-year-old HVAC system consisting of basement-located furnace with air handler and outdoor Daikin condensing unit. Began service with exterior AC unit per customer request due to pets, performing visual inspection of condenser cabinet, fan assembly, refrigerant line connections, and electrical conduit routing. Unit showed good overall condition with minimal weathering on cabinet exterior and properly secured mounting platform with PVC support structure. Proceeded to interior furnace inspection after exterior work completed, removing access panel to examine blower motor assembly, electrical connections, capacitors, and control wiring. Verified proper wire terminations at terminal block with color-coded connections intact, inspected blower motor and associated electrical components for signs of wear or damage, and examined refrigerant accumulator and associated piping. All internal components showed normal operating condition with no
Completed comprehensive Gold AC inspection on a 5-year-old Bryant outdoor condensing unit located on exterior pad against foundation. Performed full system evaluation including visual inspection of condenser cabinet, cooling fins, fan guard assembly, and unit mounting. Verified equipment operational status, assessed overall system condition, and documented unit placement on black plastic pad with proper clearances from building structure. Equipment showed normal weathering consistent with age and outdoor installation, with all major components functioning as designed.
Responded to service call for tanked water heater that would not stay lit. Upon arrival, accessed basement utility room through side entrance per homeowner instructions. Inspected blue cylindrical residential water heater unit and associated gas supply line, pilot assembly, thermocouple, and burner components. Diagnosed pilot light failure preventing unit from maintaining ignition. Performed troubleshooting of gas control valve, tested thermocouple operation, and cleaned pilot orifice. Verified proper gas flow and pressure to burner assembly. Re-lit pilot light, confirmed stable flame, and tested burner ignition cycle for proper operation. Inspected all plumbing connections at top of unit including copper hot water outlet and cold water inlet for leaks. Verified temperature and pressure relief valve functionality and checked flue pipe connections for proper draft. Unit restored to full operational status with pilot remaining lit and burner cycling normally to maintain water temperature
Responded to service call for intermittent loud noise from 2022 air handler located in attic. Accessed unit through closet entry point. Inspected air handler and found filter requiring replacement, which was contributing to excessive dust circulation throughout home. Replaced filter and verified proper airflow. Proceeded to outdoor condenser unit and found significant dirt and debris accumulation on exterior panels and coil surfaces, restricting airflow and potentially causing strain on system components. Cleaned condenser coils and exterior surfaces to restore proper heat exchange efficiency. Cycled system through complete operational test, monitoring for noise concerns and verifying normal operating pressures and temperatures. Unit operating within manufacturer specifications at time of departure.
Responded to basement drain backup with no prior repair attempts. Performed camera inspection of basement floor drains to diagnose the blockage and assess drain line condition. Utilized pipe wrench and plumbing tools to access drain openings in concrete floor. Documented existing plumbing infrastructure including vertical copper supply lines with visible oxidation and aging. Camera inspection completed to identify location and nature of obstruction in drainage system.