With average temperatures in Grosse Pointe reaching lows of around 16 degrees Fahrenheit in the winter and highs of around 77 degrees Fahrenheit in the summer, you want to ensure you and your family remain warm or cool all year round.
The team at FLAME Heating, Cooling, Plumbing & Electrical can take care of all your heating and cooling in Grosse Point and surrounding areas. As your go-to HVAC provider in Michigan, we can help keep your home comfortable in all seasons.
Furnace Repair and Installation in Grosse Point
Furnaces keep your home warm even in the coldest months, and we can work with any brand or model. We provide the following furnace services:
- Furnace installation: Our technicians can install an electric or gas furnace and will do all the checks to make sure it’s running smoothly.
- Furnace maintenance and repair: If you notice your furnace is acting unusually and not providing enough heat, our team can help. We’ll inspect the unit and complete the required repairs.
Other types of heaters we install include:
- Combination boilers
- Boilers
- Heat pumps
- Ductless mini-splits
- Packaged units
AC Repair and Installation
Whether you want a ductless mini-split system or another air conditioning unit, FLAME Heating, Cooling, Plumbing & Electrical has the solutions to keep you cool and comfortable during the hot months. Our AC services include:
- AC installation: No project is too big or small for us. We’ll install the AC unit, set up the connections, and run the tests. Rest assured of comprehensive assistance when you choose us.
- AC maintenance and repair: If you’re looking for AC repair services in Grosse Pointe, you have come to the right place. As soon as you schedule a service with us, our technicians will drive to your home and restore your AC so it’s working as usual again.
Why Work With FLAME Heating, Cooling, Plumbing & Electrical?
Our team goes above and beyond, using quality tools, brands, and the latest industry technology to upgrade or repair your HVAC system. Our goal is for you to be comfortable in your living spaces and happy with your unit, which is why we provide the highest quality products and services.
Trusted HVAC Services
We only employ skilled and experienced HVAC technicians, allowing us to offer premium HVAC services in Grosse Point.
Fast Response in the Local Area
At FLAME Heating, Cooling, Plumbing & Electrical, we respect your time and want to install or repair your system as quickly as possible. That’s why we respond fast to your Grosse Pointe HVAC needs.
Competitive, Transparent Pricing
Get value for your money and budget with ease with our reasonable, transparent prices.
Contact Us Today for Reliable Heating and Cooling Services
Get started and schedule your appointment by calling us at 586-271-8813 or contacting us online.
Recent Jobs and Reviews in Grosse Pointe , MI
Grosse Pointe, MI at a glance
Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Grosse Pointe, MI between August 2026 and September 2026.
The most recent job was on September 10, 2026.
Job Locations and Reviews
Completed comprehensive Gold AC Inspection and preventive maintenance on a 1.5-2 year old air conditioning system and heating furnace located in basement. Performed full system diagnostics, inspected all internal components including blower motor assembly, electrical connections, gas lines, and refrigerant lines. Verified proper operation of all mechanical and electrical systems, checked wire terminations and connections, examined PVC intake and exhaust venting, and confirmed all safety controls functioning correctly. No issues found; system operating within normal parameters.
Completed boiler skim and startup procedure following new installation. Removed manufacturing oils and debris from boiler system through skimming process, flushed system to ensure clean operation, and performed comprehensive startup checks including burner ignition, flame sensor verification, and control sequence testing. Confirmed proper venting operation, verified all electrical connections within control panel, and validated system pressurization and water flow throughout the heating loop.
Performed comprehensive Gold-level boiler inspection on 13-year-old unit located in basement. Conducted combustion analysis using digital diagnostic meter, recording oxygen levels at 11.8%, efficiency rating of 23 EDF, and flue gas temperature of 298.9°F. All system parameters were within acceptable operating ranges, and equipment was found to be functioning properly at time of inspection.
Completed three-day boiler replacement installation including mechanical, electrical, and boiler permits with reconnection services. Installed new boiler system with automatic blowoff assembly, connected all supply and return piping, integrated PVC venting and drainage components, and verified proper operation of all controls and safety devices. All work performed to code with permits obtained and system commissioned successfully.
Conducted estimate for replacement of 10+ year old Spacepack system with attic-mounted natural gas furnace. Current equipment operational but aging, with visible dust accumulation on interior vent grilles and flexible ductwork in attic space. Documented existing installation including flexible duct routing, insulation condition, and equipment accessibility for replacement planning.
Completed comprehensive tune-up inspection on multi-zone HVAC system including gas furnace with Trion HE 1400 air handler located in basement, with additional units in backyard and second floor. Performed thorough inspection of all accessible components including burner assembly, heat exchanger, blower motor, gas lines, electrical connections, humidifier, thermostat, and hot water tank. All systems checked for proper operation and safety compliance.
Responded to service call for insufficient hot water production from tanked water heater system. Accessed basement utility room through tenant units to inspect dual A.O. Smith water heater installation consisting of units #2 and #3. Performed diagnostic evaluation of both tanked water heaters, examining gas control valves, copper supply and distribution piping, shut-off valves, and overall system configuration. Inspected manufacturer labels, safety warnings, and operational specifications on both units. Assessed piping connections, joints, elbows, and valve assemblies for proper function. Evaluated gas supply system and burner operation to determine cause of inadequate heating capacity. Documented existing installation condition including copper piping patina, insulated pipe runs, and dual-unit configuration designed for high-capacity residential hot water demand.
Completed comprehensive Gold membership inspection on 8-year-old HVAC system consisting of basement-located furnace with air handler and outdoor Daikin condensing unit. Began service with exterior AC unit per customer request due to pets, performing visual inspection of condenser cabinet, fan assembly, refrigerant line connections, and electrical conduit routing. Unit showed good overall condition with minimal weathering on cabinet exterior and properly secured mounting platform with PVC support structure. Proceeded to interior furnace inspection after exterior work completed, removing access panel to examine blower motor assembly, electrical connections, capacitors, and control wiring. Verified proper wire terminations at terminal block with color-coded connections intact, inspected blower motor and associated electrical components for signs of wear or damage, and examined refrigerant accumulator and associated piping. All internal components showed normal operating condition with no
Completed comprehensive Gold AC inspection on a 5-year-old Bryant outdoor condensing unit located on exterior pad against foundation. Performed full system evaluation including visual inspection of condenser cabinet, cooling fins, fan guard assembly, and unit mounting. Verified equipment operational status, assessed overall system condition, and documented unit placement on black plastic pad with proper clearances from building structure. Equipment showed normal weathering consistent with age and outdoor installation, with all major components functioning as designed.
Responded to service call for tanked water heater that would not stay lit. Upon arrival, accessed basement utility room through side entrance per homeowner instructions. Inspected blue cylindrical residential water heater unit and associated gas supply line, pilot assembly, thermocouple, and burner components. Diagnosed pilot light failure preventing unit from maintaining ignition. Performed troubleshooting of gas control valve, tested thermocouple operation, and cleaned pilot orifice. Verified proper gas flow and pressure to burner assembly. Re-lit pilot light, confirmed stable flame, and tested burner ignition cycle for proper operation. Inspected all plumbing connections at top of unit including copper hot water outlet and cold water inlet for leaks. Verified temperature and pressure relief valve functionality and checked flue pipe connections for proper draft. Unit restored to full operational status with pilot remaining lit and burner cycling normally to maintain water temperature
Responded to service call for intermittent loud noise from 2022 air handler located in attic. Accessed unit through closet entry point. Inspected air handler and found filter requiring replacement, which was contributing to excessive dust circulation throughout home. Replaced filter and verified proper airflow. Proceeded to outdoor condenser unit and found significant dirt and debris accumulation on exterior panels and coil surfaces, restricting airflow and potentially causing strain on system components. Cleaned condenser coils and exterior surfaces to restore proper heat exchange efficiency. Cycled system through complete operational test, monitoring for noise concerns and verifying normal operating pressures and temperatures. Unit operating within manufacturer specifications at time of departure.
Responded to basement drain backup with no prior repair attempts. Performed camera inspection of basement floor drains to diagnose the blockage and assess drain line condition. Utilized pipe wrench and plumbing tools to access drain openings in concrete floor. Documented existing plumbing infrastructure including vertical copper supply lines with visible oxidation and aging. Camera inspection completed to identify location and nature of obstruction in drainage system.
Replaced defective condenser fan motor on Lennox outdoor unit under PO 1362022-001. Unit tested and confirmed operating properly with new motor installed, adequate airflow restored, and system cooling as designed.
Completed full HVAC system installation including a 70,000 BTU furnace and 2.5 ton air conditioning unit with all associated components. Installed new programmable thermostat, humidifier, and chimney liner for proper venting. Positioned outdoor condensing unit in right side yard location with appropriate clearances. Ran new electrical service and reconnected all utilities to existing meter. Requested and obtained mechanical, electrical, and furnace permits prior to installation. System tested and verified operational upon completion, qualifying for utility rebate program.
Performed comprehensive evaluation of 20-year-old air conditioning system experiencing complete cooling failure with suspected refrigerant loss. Assessed outdoor condensing unit, indoor air handler, and ductwork system throughout the property. Based on the age of the equipment, extent of refrigerant loss, and overall system condition, provided detailed estimate for complete HVAC system replacement including new outdoor unit, indoor evaporator coil, associated ductwork modifications, and refrigerant lines to restore reliable cooling operation.
Responded to service call for non-functioning air conditioning system with no cooling throughout property. Accessed attic-mounted HVAC system through side entry and performed comprehensive assessment of existing air handler unit, flexible ductwork, and associated components. Documented current system condition including aged equipment, black flexible duct routing, insulation status, and overall installation configuration. Provided detailed replacement estimate for complete air conditioning system upgrade to restore cooling functionality.
Responded to basement plumbing issue where drain pipes had become clogged. Upon arrival, assessed the drainage system and PVC piping configuration in the basement utility area. Successfully cleared the blockage using professional-grade equipment, restoring proper water flow and drainage function to the affected pipes.
Responded to callback for dishwasher drainage issue where water was not properly evacuating from the appliance. Upon inspection of the under-sink plumbing system, examined the garbage disposal unit, drain connections, and dishwasher discharge line for potential blockages or improper drainage. Inspected all PVC trap assemblies, flexible hoses, and connection points beneath the kitchen sink for leaks or obstructions that could impede proper water flow from the dishwasher. Documented existing water staining on flooring beneath cabinet, indicating previous moisture issues. Verified all plumbing connections to disposal unit and drain system for proper installation and function.
Responded to no-cooling call on 20-year-old residential air conditioning system. Upon inspection, found outdoor condensing unit completely depleted of refrigerant, indicating significant leak in aged system. Evaluated dual capacitor and electrical connections, which showed considerable weathering and dust accumulation consistent with unit age. Inspected indoor blower motor assembly, confirming operational status. Given the system's age at two decades—well beyond typical 15-year lifespan—and complete refrigerant loss, advised customer that locating and repairing leak followed by recharge would not be cost-effective compared to full system replacement. Documented equipment condition with photos showing capacitor, wiring connections, and blower assembly. Recommended replacement with modern high-efficiency unit to restore cooling and improve energy performance.
Completed comprehensive Gold AC Inspection on a 3-year-old air conditioning system with outdoor condenser unit located in basement area. Performed full system evaluation including visual inspection of condenser unit, fan assembly, and housing condition; checked refrigerant levels, electrical connections, and overall operational performance. Unit showed normal wear with minor dust accumulation on fan grille and housing but is functioning within manufacturer specifications with no immediate service needs identified.