It is said that the city of Novi in Michigan is “on the way to anywhere.” This is ideal for new businesses, as well as residents who enjoy world-class shopping and eateries. FLAME Heating, Cooling, Plumbing and Electrical is here to provide the best in heating and cooling for the people and business owners of Novi and surrounding areas.
FLAME offers over 67 years of experience in the industry and installs only the finest HVAC products.
Our wide-variety of home options include energy efficient gas furnaces, air conditioners or small package systems. Call today and learn about our highly efficient HYBRID HEAT® dual fuel system.
And Don’t Forget…
FLAME technicians are now certified and insured to perform electrical repairs and installations in Novi.
Call us today or sign up online and we’ll call you!
(888) 234-2340
Recent Jobs and Reviews in Novi , MI
Job Locations and Reviews
Completed comprehensive Gold AC inspection on 7-year-old residential air conditioning system with air handler/coil located in basement. Verified system operational status and confirmed single-unit configuration. Performed standard multi-point inspection protocol including refrigerant levels, electrical connections, condensate drain functionality, air filter condition, thermostat calibration, and overall system performance. Documented equipment specifications and current operating conditions through photographic records of thermostat controls and related mechanical systems. All components found functioning within normal parameters with no immediate service needs identified at time of inspection.
Completed comprehensive Gold AC Inspection on residential split system with outdoor condenser unit installed in 2023 and furnace located in basement. Performed thorough visual inspection of exterior condenser unit, verified proper installation on pad with adequate clearance, checked refrigerant lines and electrical connections, and documented equipment condition through photographs. Unit found to be in good operating condition with no visible deficiencies noted.
Completed Gold AC Inspection on a 4-year-old residential air conditioning system with outdoor condenser unit and basement-located air handler. Performed comprehensive maintenance evaluation of the outdoor unit positioned on concrete pad against brick exterior, verified proper installation on vibration dampening pad, inspected condenser coils through side grilles for cleanliness and damage, checked electrical connections and disconnect box mounting, and assessed overall system condition. Unit showed proper installation with adequate clearance, decorative lattice screening for aesthetic purposes, and appropriate electrical conduit routing, with all components appearing operational and well-maintained for the equipment age.
Responded to emergency call for broken copper water line where exterior pipe penetrates brick wall foundation and enters the building. Upon arrival, found interior wall already opened providing direct access to damaged section. Replaced compromised copper piping segment at wall penetration point, installed new fittings and connections, and pressure tested entire system to verify integrity. Confirmed all shut-off valves operational and no additional leaks present in surrounding plumbing assembly.
Installed and reconnected a 75-gallon tanked water heater in the utility room, completing all plumbing connections with copper piping and properly venting the unit through the existing exhaust system. Floor protection was utilized throughout the work area to prevent damage to hardwood flooring during the installation process. All manufacturer specifications were followed, connections were tested for proper operation, and the unit was commissioned successfully.
Responded to no heat call on 3-year-old furnace located in basement. Performed diagnostic testing using combustion analyzer, which revealed system was not operating. Inspected pressure switches, gas valve assembly, and electrical connections throughout the unit. Restored heat to the system, performed complete maintenance service including filter replacement and full system inspection. Also completed air conditioning system inspection and renewed maintenance plan as requested.
Completed Gold AC Inspection on a 10+ year old Diamond Plus outdoor condensing unit. Performed comprehensive system evaluation including visual inspection of exterior components, fan assembly, and protective grills. Unit was operational at time of inspection with condenser positioned on concrete pad in landscaped area. Documented equipment condition showing normal weathering and exterior dirt accumulation consistent with outdoor exposure and age. Verified proper unit placement and clearances around condenser for adequate airflow.
Responded to service call for toilet leaking from the bottom. Upon inspection, identified source of leak and performed necessary repairs to restore proper seal and functionality. Tested unit after completion to verify leak was eliminated and toilet was operating correctly.
Completed comprehensive Gold AC Inspection on 2016 Bryant outdoor condenser unit and basement-located air handler system. System confirmed operational with condenser positioned on proper pad foundation with adequate clearance, decorative rock surround maintained clear of debris, and all exterior components including fan grille and refrigerant lines in good condition showing normal weathering consistent with unit age.
Responded to service call for inadequate hot water temperature from basement water heater. Upon inspection, identified issue with tanked water heater system not producing sufficient heat output. Performed diagnostic evaluation and made necessary adjustments to restore proper water heating function to manufacturer specifications.
Completed comprehensive air conditioning tune-up and inspection on a 9-year-old Bryant residential cooling system with air handler located in basement. Performed standard preventive maintenance protocol including visual inspection of outdoor condenser unit, verified proper operation of all components, and assessed overall system condition. Unit found to be operating within normal parameters with no immediate service concerns identified at time of inspection.
Responded to basement sump pump backup issue affecting drainage system. Upon inspection, identified backup sump pump malfunction in utility area. Evaluated existing primary and backup sump pump configuration, including discharge piping system with dual vertical PVC pipes mounted to foundation wall. Assessed pump operation, float switch functionality, and discharge line integrity. Addressed backup pump failure that had been present for 1-2 days, restoring proper secondary pump operation to ensure continued basement water protection. Verified both primary and backup systems operational, confirmed proper drainage flow through discharge lines, and tested system cycling under load conditions. Basement water management system returned to full operational status with redundant pump protection restored.
Completed comprehensive Gold-level furnace inspection on residential forced-air heating system located in basement. Unit is less than 10 years old and operational at time of service. Performed thorough visual examination of burner assembly, confirming proper ignition sequence with uniform blue flame pattern across all five burner ports indicating optimal air-to-fuel mixture and complete combustion. Inspected internal components including electrical connections, wiring harness, motor assemblies, and mounting hardware—all found to be secure and in good working condition. Examined exterior condensing unit positioned on concrete pad against structure, verified fan operation and protective grille integrity, checked refrigerant line connections and condensate drainage system. Documented equipment condition with photographs showing active burner flames, internal component layout, and exterior unit installation. All systems functioning within normal operating parameters with no immediate safet
Responded to a plumbing leak originating from the kitchen sink and extending down to the laundry room area. Upon inspection, identified water damage to flooring and surrounding areas consistent with a progressive leak that had significantly worsened over recent days. Performed drain snaking service to clear blockage and address drainage issues contributing to the leak. Assessed plumbing connections and drainage system in the affected areas, documented conditions with photographic evidence showing workspace setup and equipment utilized during service. Completed necessary repairs to resolve the active leak and restore proper drainage function between the kitchen sink and laundry room in the residential property.
Responded to electrical code violation for air conditioning unit with improperly rated overcurrent protection. Replaced existing 30-amp fuses with correct 25-amp fuses per manufacturer specifications and local electrical code requirements, restoring the system to compliant operation.
Conducted site assessment for AC installation at commercial location with existing gas furnace and water heater in utility room. Evaluated space constraints and existing mechanical systems to determine appropriate equipment specifications. Customer requires new AC system installation with no existing cooling infrastructure present.
Successfully installed a 4-ton A/C unit and coil, completing all required refrigerant and electrical connections. Replaced aging components showing significant oxidation and corrosion, particularly on copper lines and metal surfaces. System now operational with all wiring properly connected to control board and blower assembly.
Diagnosed fluctuating water temperature issue on two commercial tankless water heaters. Inspected plumbing connections and drain assembly, identifying faulty flow sensor as the cause of temperature inconsistency. Replaced defective components and verified proper operation of both units, ensuring stable water temperature delivery to the three-compartment sink system.
Completed installation of a 40-gallon Icon System water heater in basement location. Unit features temperature control panel with safety settings and pilot light system. Installation included proper connection to existing plumbing infrastructure and verification of proper operation alongside Bryant furnace system.
Responded to callback regarding furnace continuous operation after maintenance. Inspected three units located in attic, all over 10 years old. Discovered and repaired damaged electrical connector on control board, which was causing the continuous run issue. All furnaces now cycling properly and operating within normal parameters.