Heating and Cooling Taylor

The city of Taylor in Wayne County is a part of what is known as the “Downriver” community in Southeast Michigan. Taylor is also home to the Southland Shopping Center, the Taylor Sportsplex, and the Taylor Meadows Golf course. Let FLAME focus on your heating and cooling needs, so you can focus on everything else that Taylor has to offer.

Taylor is proudly the birthplace of Hungry Howie’s Pizza. Residents that keep their families full also need to keep their homes comfortable. FLAME helps you stay comfy all year long with high quality heating and cooling products like a highly efficient gas furnace. And, when it comes to humid Michigan summers, FLAME has the perfect air conditioner for your home. FLAME also has dehumidifiers, to keep the excess moisture out of your basements.

Call FLAME today, at (586) 217-2512, or sign up online, and we’ll call you!

Recent Jobs and Reviews in Taylor , MI

Taylor, MI at a glance

Flame Heating, Cooling, Plumbing, Electrical has completed 20 jobs in Taylor, MI between June 2026 and September 2026.

The most recent job was on September 29, 2026.

Flame Heating, Cooling, Plumbing, Electrical has completed 68 jobs in Taylor, MI in the last 12 months.

Job Locations and Reviews

Completed comprehensive Gold furnace inspection on 10+ year old forced air unit located in basement. Performed combustion analysis using digital analyzer, recording optimal readings: 93.0% efficiency, 31 ppm CO, 9.4% O₂, 6.5% CO₂, and 108°F stack temperature. All measurements within acceptable parameters indicating proper combustion and system operation, with unit functioning normally at time of inspection.
Completed comprehensive Gold furnace inspection on 10+ year old forced air unit located in basement. Performed combustion analysis using digital analyzer, recording optimal readings: 93.0% efficiency, 31 ppm CO, 9.4% O₂, 6.5% CO₂, and 108°F stack temperature. All measurements within acceptable parameters indicating proper combustion and system operation, with unit functioning normally at time of inspection.
FL W.
FL W. Checked in
Completed comprehensive Gold furnace inspection on 10+ year old forced air unit located in basement. Performed combustion analysis using digital analyzer, recording optimal readings: 93.0% efficiency, 31 ppm CO, 9.4% O₂, 6.5% CO₂, and 108°F stack temperature. All measurements within acceptable parameters indicating proper combustion and system operation, with unit functioning normally at time of inspection.
Taylor, MI 48180
Taylor, MI - Performed site assessment of HVAC system requiring thermostat and condenser wiring upgrade. Identified need for shielded wire installation to run from thermostat location to outdoor condensing unit. Documented existing smart thermostat control panel and wall conditions with photos for future wire routing reference.
RZ H.
RZ H. Checked in
Performed site assessment of HVAC system requiring thermostat and condenser wiring upgrade. Identified need for shielded wire installation to run from thermostat location to outdoor condensing unit. Documented existing smart thermostat control panel and wall conditions with photos for future wire routing reference.
Taylor, MI 48180
Responded to service call for rooftop unit not operating properly at commercial facility. Accessed RTU via ladder on flat membrane roof. Upon inspection, found unit's filter/coil section heavily contaminated with dirt and debris accumulation, restricting airflow and reducing system efficiency. Documented existing conditions showing significant soiling on coil guard and general unit maintenance needs. Unit requires thorough coil cleaning and filter replacement to restore proper operation and cooling capacity.
Responded to service call for rooftop unit not operating properly at commercial facility. Accessed RTU via ladder on flat membrane roof. Upon inspection, found unit's filter/coil section heavily contaminated with dirt and debris accumulation, restricting airflow and reducing system efficiency. Documented existing conditions showing significant soiling on coil guard and general unit maintenance needs. Unit requires thorough coil cleaning and filter replacement to restore proper operation and cooling capacity.
FL C.
FL C. Checked in
Responded to service call for rooftop unit not operating properly at commercial facility. Accessed RTU via ladder on flat membrane roof. Upon inspection, found unit's filter/coil section heavily contaminated with dirt and debris accumulation, restricting airflow and reducing system efficiency. Documented existing conditions showing significant soiling on coil guard and general unit maintenance needs. Unit requires thorough coil cleaning and filter replacement to restore proper operation and cooling capacity.
Taylor, MI 48180
Completed comprehensive furnace inspection and tune-up on a 12-15 year old Bryant forced air system located in basement. Performed combustion analysis using Bacharach analyzer, which confirmed optimal performance with 93.7% efficiency, 37 ppm CO, 7.4% O2, 7.6% CO2, and 110°F stack temperature. Inspected blower motor assembly, electrical connections, and internal components; all found to be in proper working condition with no immediate repairs needed.
Completed comprehensive furnace inspection and tune-up on a 12-15 year old Bryant forced air system located in basement. Performed combustion analysis using Bacharach analyzer, which confirmed optimal performance with 93.7% efficiency, 37 ppm CO, 7.4% O2, 7.6% CO2, and 110°F stack temperature. Inspected blower motor assembly, electrical connections, and internal components; all found to be in proper working condition with no immediate repairs needed.
FL W.
FL W. Checked in
Completed comprehensive furnace inspection and tune-up on a 12-15 year old Bryant forced air system located in basement. Performed combustion analysis using Bacharach analyzer, which confirmed optimal performance with 93.7% efficiency, 37 ppm CO, 7.4% O2, 7.6% CO2, and 110°F stack temperature. Inspected blower motor assembly, electrical connections, and internal components; all found to be in proper working condition with no immediate repairs needed.
Taylor, MI 48180
Performed comprehensive tune-up on five-year-old furnace located in basement. Conducted complete system inspection including burner assembly, heat exchanger, blower motor, and all safety controls. Verified proper operation of ignition system, tested airflow, and confirmed all components functioning within manufacturer specifications with no issues identified.
Performed comprehensive tune-up on five-year-old furnace located in basement. Conducted complete system inspection including burner assembly, heat exchanger, blower motor, and all safety controls. Verified proper operation of ignition system, tested airflow, and confirmed all components functioning within manufacturer specifications with no issues identified.
FL M.
FL M. Checked in
Performed comprehensive tune-up on five-year-old furnace located in basement. Conducted complete system inspection including burner assembly, heat exchanger, blower motor, and all safety controls. Verified proper operation of ignition system, tested airflow, and confirmed all components functioning within manufacturer specifications with no issues identified.
Taylor, MI 48180
Completed on-site assessment of plumbing configuration conflict where existing water supply lines and PVC drain connections protruding from floor were preventing relocation of stackable washer/dryer unit that was blocking side door access. Evaluated current utility sink installation with existing copper water supply lines, braided flex connectors, and floor-mounted P-trap assembly. Provided professional recommendations for reconfiguring water supply and drain piping to allow appliance repositioning while maintaining functionality of utility sink, including options for relocating stub-outs and drain connections to accommodate both fixtures in desired layout.
Completed on-site assessment of plumbing configuration conflict where existing water supply lines and PVC drain connections protruding from floor were preventing relocation of stackable washer/dryer unit that was blocking side door access. Evaluated current utility sink installation with existing copper water supply lines, braided flex connectors, and floor-mounted P-trap assembly. Provided professional recommendations for reconfiguring water supply and drain piping to allow appliance repositioning while maintaining functionality of utility sink, including options for relocating stub-outs and drain connections to accommodate both fixtures in desired layout.
FL A.
FL A. Checked in
Completed on-site assessment of plumbing configuration conflict where existing water supply lines and PVC drain connections protruding from floor were preventing relocation of stackable washer/dryer unit that was blocking side door access. Evaluated current utility sink installation with existing copper water supply lines, braided flex connectors, and floor-mounted P-trap assembly. Provided professional recommendations for reconfiguring water supply and drain piping to allow appliance repositioning while maintaining functionality of utility sink, including options for relocating stub-outs and drain connections to accommodate both fixtures in desired layout.
Taylor, MI 48180
Completed preventative maintenance and filter replacement on two rooftop HVAC units at commercial facility. Accessed roof-mounted RTUs and replaced 20x30x2 filters on both units per maintenance schedule. All equipment operational upon completion with proper airflow restored.
Completed preventative maintenance and filter replacement on two rooftop HVAC units at commercial facility. Accessed roof-mounted RTUs and replaced 20x30x2 filters on both units per maintenance schedule. All equipment operational upon completion with proper airflow restored.
FL C.
FL C. Checked in
Completed preventative maintenance and filter replacement on two rooftop HVAC units at commercial facility. Accessed roof-mounted RTUs and replaced 20x30x2 filters on both units per maintenance schedule. All equipment operational upon completion with proper airflow restored.
Taylor, MI 48180
Taylor, MI - Installed ground fault circuit interrupter (GFI) outlet at exterior deck location to provide code-compliant electrical protection for outdoor receptacle. Verified proper wiring connections, tested device functionality, and confirmed GFI trips appropriately when ground fault is detected.
FL B.
FL B. Checked in
Installed ground fault circuit interrupter (GFI) outlet at exterior deck location to provide code-compliant electrical protection for outdoor receptacle. Verified proper wiring connections, tested device functionality, and confirmed GFI trips appropriately when ground fault is detected.
Taylor, MI 48180
Responded to service call for water leaking from bottom of furnace causing wet floors in encapsulated crawl space. Upon inspection, found recently installed furnace and AC system with unit not shutting off properly, though system was still providing cooling. Identified water intrusion originating from underneath the unit area. Inspected exterior condensate drainage system and flexible discharge line routing. Photographed conditions including crawl space access point and exterior mechanical components with drainage piping. Documented weathered deck structure near unit location and condensate line pathway through vegetation and ground-level area. System evaluated for proper drainage function and potential sources of water accumulation beneath furnace installation.
Responded to service call for water leaking from bottom of furnace causing wet floors in encapsulated crawl space. Upon inspection, found recently installed furnace and AC system with unit not shutting off properly, though system was still providing cooling. Identified water intrusion originating from underneath the unit area. Inspected exterior condensate drainage system and flexible discharge line routing. Photographed conditions including crawl space access point and exterior mechanical components with drainage piping. Documented weathered deck structure near unit location and condensate line pathway through vegetation and ground-level area. System evaluated for proper drainage function and potential sources of water accumulation beneath furnace installation.
FL W.
FL W. Checked in
Responded to service call for water leaking from bottom of furnace causing wet floors in encapsulated crawl space. Upon inspection, found recently installed furnace and AC system with unit not shutting off properly, though system was still providing cooling. Identified water intrusion originating from underneath the unit area. Inspected exterior condensate drainage system and flexible discharge line routing. Photographed conditions including crawl space access point and exterior mechanical components with drainage piping. Documented weathered deck structure near unit location and condensate line pathway through vegetation and ground-level area. System evaluated for proper drainage function and potential sources of water accumulation beneath furnace installation.
Taylor, MI 48180
Completed full HVAC system installation including a 70,000 BTU furnace and 2.5-ton air conditioning unit in left-side utility closet configuration. Performed system flush, installed condensate pump, reconnected electrical service, and installed 16x25x1 filter. Mechanical and electrical permits were obtained prior to installation, and all ductwork connections were secured and sealed to manufacturer specifications.
Completed full HVAC system installation including a 70,000 BTU furnace and 2.5-ton air conditioning unit in left-side utility closet configuration. Performed system flush, installed condensate pump, reconnected electrical service, and installed 16x25x1 filter. Mechanical and electrical permits were obtained prior to installation, and all ductwork connections were secured and sealed to manufacturer specifications.
FL L.
FL L. Checked in
Completed full HVAC system installation including a 70,000 BTU furnace and 2.5-ton air conditioning unit in left-side utility closet configuration. Performed system flush, installed condensate pump, reconnected electrical service, and installed 16x25x1 filter. Mechanical and electrical permits were obtained prior to installation, and all ductwork connections were secured and sealed to manufacturer specifications.
Taylor, MI 48180
Conducted comprehensive site assessment for full HVAC system installation in residential property with no existing equipment. Evaluated basement area and crawl space access for optimal furnace placement, noting floor construction and available utility connections. Documented existing conditions including unfinished space, electrical infrastructure, and water presence in subfloor area to determine equipment specifications and installation requirements for both heating and cooling systems, with primary focus on furnace installation per homeowner preference.
Conducted comprehensive site assessment for full HVAC system installation in residential property with no existing equipment. Evaluated basement area and crawl space access for optimal furnace placement, noting floor construction and available utility connections. Documented existing conditions including unfinished space, electrical infrastructure, and water presence in subfloor area to determine equipment specifications and installation requirements for both heating and cooling systems, with primary focus on furnace installation per homeowner preference.
FL S.
FL S. Checked in
Conducted comprehensive site assessment for full HVAC system installation in residential property with no existing equipment. Evaluated basement area and crawl space access for optimal furnace placement, noting floor construction and available utility connections. Documented existing conditions including unfinished space, electrical infrastructure, and water presence in subfloor area to determine equipment specifications and installation requirements for both heating and cooling systems, with primary focus on furnace installation per homeowner preference.
Taylor, MI 48180
Responded to service call for fluid leaking from 12-year-old furnace located in basement. Upon inspection, identified source of leak as heavily clogged humidifier pad with significant mineral buildup and debris accumulation causing water overflow from humidifier unit. Removed and inspected saturated evaporator pad, which showed extensive contamination and reduced water flow capacity. Replaced soiled humidifier filter pad with new unit, cleared drain pan of accumulated sediment, and verified proper water flow and drainage operation. System tested and returned to normal operation with no further leaking observed.
Responded to service call for fluid leaking from 12-year-old furnace located in basement. Upon inspection, identified source of leak as heavily clogged humidifier pad with significant mineral buildup and debris accumulation causing water overflow from humidifier unit. Removed and inspected saturated evaporator pad, which showed extensive contamination and reduced water flow capacity. Replaced soiled humidifier filter pad with new unit, cleared drain pan of accumulated sediment, and verified proper water flow and drainage operation. System tested and returned to normal operation with no further leaking observed.
FL F.
FL F. Checked in
Responded to service call for fluid leaking from 12-year-old furnace located in basement. Upon inspection, identified source of leak as heavily clogged humidifier pad with significant mineral buildup and debris accumulation causing water overflow from humidifier unit. Removed and inspected saturated evaporator pad, which showed extensive contamination and reduced water flow capacity. Replaced soiled humidifier filter pad with new unit, cleared drain pan of accumulated sediment, and verified proper water flow and drainage operation. System tested and returned to normal operation with no further leaking observed.
Taylor, MI 48180
Responded to service call for toilet not flushing properly. Upon inspection, diagnosed and addressed the flushing mechanism issue. Tested toilet operation to ensure proper flush function and water flow were restored to normal working condition.
Responded to service call for toilet not flushing properly. Upon inspection, diagnosed and addressed the flushing mechanism issue. Tested toilet operation to ensure proper flush function and water flow were restored to normal working condition.
FL B.
FL B. Checked in
Responded to service call for toilet not flushing properly. Upon inspection, diagnosed and addressed the flushing mechanism issue. Tested toilet operation to ensure proper flush function and water flow were restored to normal working condition.
Taylor, MI 48180
Installed ground fault circuit interrupter (GFI) protection at exterior location near brick wall and chain-link fence boundary. Accessed main electrical panel in attic space, identified appropriate circuit for outdoor receptacle, and configured GFI breaker to provide required ground fault protection for exterior outlet. Verified proper operation of GFI device and confirmed circuit integrity upon completion.
Installed ground fault circuit interrupter (GFI) protection at exterior location near brick wall and chain-link fence boundary. Accessed main electrical panel in attic space, identified appropriate circuit for outdoor receptacle, and configured GFI breaker to provide required ground fault protection for exterior outlet. Verified proper operation of GFI device and confirmed circuit integrity upon completion.
FL B.
FL B. Checked in
Installed ground fault circuit interrupter (GFI) protection at exterior location near brick wall and chain-link fence boundary. Accessed main electrical panel in attic space, identified appropriate circuit for outdoor receptacle, and configured GFI breaker to provide required ground fault protection for exterior outlet. Verified proper operation of GFI device and confirmed circuit integrity upon completion.
Taylor, MI 48180
Conducted comprehensive assessment of existing 20-year-old furnace system located in utility closet for potential central air conditioning integration. Evaluated current HVAC infrastructure including furnace unit, existing ductwork configuration, and available space for AC component installation. Documented equipment specifications, duct routing through basement area, and structural considerations necessary for complete system upgrade. Photographed furnace unit with visible manufacturer labeling and existing metallic supply duct system to support estimate preparation for full HVAC system installation.
Conducted comprehensive assessment of existing 20-year-old furnace system located in utility closet for potential central air conditioning integration. Evaluated current HVAC infrastructure including furnace unit, existing ductwork configuration, and available space for AC component installation. Documented equipment specifications, duct routing through basement area, and structural considerations necessary for complete system upgrade. Photographed furnace unit with visible manufacturer labeling and existing metallic supply duct system to support estimate preparation for full HVAC system installation.
FL M.
FL M. Checked in
Conducted comprehensive assessment of existing 20-year-old furnace system located in utility closet for potential central air conditioning integration. Evaluated current HVAC infrastructure including furnace unit, existing ductwork configuration, and available space for AC component installation. Documented equipment specifications, duct routing through basement area, and structural considerations necessary for complete system upgrade. Photographed furnace unit with visible manufacturer labeling and existing metallic supply duct system to support estimate preparation for full HVAC system installation.
Taylor, MI 48180
Responded to a slow water leak from a basement pipe that had begun to calcify. Upon inspection, identified the affected piping in the basement ceiling area and assessed the extent of mineral buildup and deterioration. Documented the condition of the plumbing system, including overhead pipe routing and structural access points for future reference and repair planning.
Responded to a slow water leak from a basement pipe that had begun to calcify. Upon inspection, identified the affected piping in the basement ceiling area and assessed the extent of mineral buildup and deterioration. Documented the condition of the plumbing system, including overhead pipe routing and structural access points for future reference and repair planning.
FL B.
FL B. Checked in
Responded to a slow water leak from a basement pipe that had begun to calcify. Upon inspection, identified the affected piping in the basement ceiling area and assessed the extent of mineral buildup and deterioration. Documented the condition of the plumbing system, including overhead pipe routing and structural access points for future reference and repair planning.
Taylor, MI 48180
Completed comprehensive Gold AC inspection on 12-year-old single-unit residential air conditioning system with outdoor condenser unit located adjacent to building foundation and air handler positioned in basement. Performed thorough visual assessment of condenser unit exterior components, including top-mounted fan assembly with protective guard, vertical louvered side panels, and housing integrity. Inspected unit for signs of age-related wear, noting weathering and surface oxidation consistent with outdoor exposure on metal components and fan guard. Evaluated ground-level installation conditions, including gravel pad placement, drainage patterns, and clearance from brick and siding exterior walls. Verified adequate airflow access through intake grilles and assessed surrounding area for debris accumulation. Documented equipment condition through photographic records showing condenser positioning, component configuration, and overall operational setup. System confirmed operational at tim
Completed comprehensive Gold AC inspection on 12-year-old single-unit residential air conditioning system with outdoor condenser unit located adjacent to building foundation and air handler positioned in basement. Performed thorough visual assessment of condenser unit exterior components, including top-mounted fan assembly with protective guard, vertical louvered side panels, and housing integrity. Inspected unit for signs of age-related wear, noting weathering and surface oxidation consistent with outdoor exposure on metal components and fan guard. Evaluated ground-level installation conditions, including gravel pad placement, drainage patterns, and clearance from brick and siding exterior walls. Verified adequate airflow access through intake grilles and assessed surrounding area for debris accumulation. Documented equipment condition through photographic records showing condenser positioning, component configuration, and overall operational setup. System confirmed operational at tim
FL F.
FL F. Checked in
Completed comprehensive Gold AC inspection on 12-year-old single-unit residential air conditioning system with outdoor condenser unit located adjacent to building foundation and air handler positioned in basement. Performed thorough visual assessment of condenser unit exterior components, including top-mounted fan assembly with protective guard, vertical louvered side panels, and housing integrity. Inspected unit for signs of age-related wear, noting weathering and surface oxidation consistent with outdoor exposure on metal components and fan guard. Evaluated ground-level installation conditions, including gravel pad placement, drainage patterns, and clearance from brick and siding exterior walls. Verified adequate airflow access through intake grilles and assessed surrounding area for debris accumulation. Documented equipment condition through photographic records showing condenser positioning, component configuration, and overall operational setup. System confirmed operational at tim
Taylor, MI 48180
Responded to plumbing service call for broken bathtub in 50-year-old residential property. Upon arrival, assessed the ongoing issue that had been affecting the bathroom for approximately one week. Shut off water heater as requested to prevent further complications and potential water damage. Documented existing conditions with photographs for service records. Completed initial diagnostic assessment and secured the affected area to ensure safe conditions for the property.
Responded to plumbing service call for broken bathtub in 50-year-old residential property. Upon arrival, assessed the ongoing issue that had been affecting the bathroom for approximately one week. Shut off water heater as requested to prevent further complications and potential water damage. Documented existing conditions with photographs for service records. Completed initial diagnostic assessment and secured the affected area to ensure safe conditions for the property.
FL J.
FL J. Checked in
Responded to plumbing service call for broken bathtub in 50-year-old residential property. Upon arrival, assessed the ongoing issue that had been affecting the bathroom for approximately one week. Shut off water heater as requested to prevent further complications and potential water damage. Documented existing conditions with photographs for service records. Completed initial diagnostic assessment and secured the affected area to ensure safe conditions for the property.
Taylor, MI 48180
Conducted comprehensive assessment of existing HVAC system for full replacement estimate. Documented current equipment configuration including Honeywell thermostat and ductwork system in attic space. Evaluated flexible metallic duct installation, sheet metal components, and air handler positioning within wooden framing structure. Coordinated customer contact prior to arrival as requested to confirm appointment and discuss system replacement requirements.
Conducted comprehensive assessment of existing HVAC system for full replacement estimate. Documented current equipment configuration including Honeywell thermostat and ductwork system in attic space. Evaluated flexible metallic duct installation, sheet metal components, and air handler positioning within wooden framing structure. Coordinated customer contact prior to arrival as requested to confirm appointment and discuss system replacement requirements.
FL S.
FL S. Checked in
Conducted comprehensive assessment of existing HVAC system for full replacement estimate. Documented current equipment configuration including Honeywell thermostat and ductwork system in attic space. Evaluated flexible metallic duct installation, sheet metal components, and air handler positioning within wooden framing structure. Coordinated customer contact prior to arrival as requested to confirm appointment and discuss system replacement requirements.
Taylor, MI 48180
Taylor, MI - Completed comprehensive Gold AC inspection on 2-year-old residential outdoor condenser unit. Performed visual assessment of equipment exterior, verified fan guard integrity, inspected manufacturer labels and safety warnings for compliance, and documented unit condition through photographic records. System confirmed operational at time of inspection with no immediate service concerns identified.
FL J.
FL J. Checked in
Completed comprehensive Gold AC inspection on 2-year-old residential outdoor condenser unit. Performed visual assessment of equipment exterior, verified fan guard integrity, inspected manufacturer labels and safety warnings for compliance, and documented unit condition through photographic records. System confirmed operational at time of inspection with no immediate service concerns identified.
Taylor, MI 48180
financing-img
Heartland Academy Learn More

What To Expect

Discover the Difference
Satisfaction Guaranteed
Licensed & Insured Services
Upfront & Fair Pricing
Background Checked Technicians
Satisfaction Guaranteed
Licensed & Insured Services
Upfront & Fair Pricing
Background Checked Technicians
discover the difference
Review Image
Our Reviews

See What Your Neighbors Are Saying

When our old furnace quit working in mid-January we called FLAME to look at it. They came right out. They send a message or email when they are on their way to you. They did a great job and were very professional and tidy about their…

Poilin B.

Poilin B.

We contacted FLAME due to a gas leak at our church. It was very nice that they sent a text message with the technician’s name photo and estimated arrival time. I feel that they went above their service responsibilities by offering to work with the gas…

Danielle K.

Danielle K.

This is my first time experience and I am completely satisfied with the speed and courtesy of the company. I called the company I had been using for over 20 years to fix my central air and was given a date 8 days out...seriously?! One call…

Tina M.

Tina M.

Used this company twice, one for a same day gas line install for my dryer and then as a second opinion on an alleged leak and low refrigerant on my AC unit per another company. Turns out that there is no leak and the refrigerant levels…

Chris S.

Chris S.

I have had some bad experiences in the recent past with other contractors. FLAME has been a god send and are in the process of fixing all my issues at a reasonable price. I am a gold member and they have already installed and serviced my…

Sandra K.

Sandra K.

Hear What Our Customers Are Saying

Learn why so many choose FLAME Heating, Cooling, Plumbing & Electrical for all their HVAC, plumbing, and electrical needs.

When our old furnace quit working in mid-January we called FLAME to look at it. They came right out. They send a message or email when they are on their way to you. They did a great job and were very professional and tidy about their work. A great crew that worked well with each other.…

Poilin B.

Poilin B.

We contacted FLAME due to a gas leak at our church. It was very nice that they sent a text message with the technician’s name photo and estimated arrival time. I feel that they went above their service responsibilities by offering to work with the gas company to find the problem. Throughout this process we also…

Danielle K.

Danielle K.

This is my first time experience and I am completely satisfied with the speed and courtesy of the company. I called the company I had been using for over 20 years to fix my central air and was given a date 8 days out...seriously?! One call to FLAME and they had Jeff out within a few…

Tina M.

Tina M.

Used this company twice, one for a same day gas line install for my dryer and then as a second opinion on an alleged leak and low refrigerant on my AC unit per another company. Turns out that there is no leak and the refrigerant levels are fine. All of FLAME technicians that I have worked…

Chris S.

Chris S.

I have had some bad experiences in the recent past with other contractors. FLAME has been a god send and are in the process of fixing all my issues at a reasonable price. I am a gold member and they have already installed and serviced my furnace, AC and water heater. Thank you for always being…

Sandra K.

Sandra K.