Located on the southeastern edge of Michigan, Ecorse is proud of its many community offerings — like Dingell Park and the Ecorse Rowing Club. After a day spent on the water or in the gazebo, Ecorse residents should expect nothing less than a perfectly cooled home in the summertime Michigan heat. FLAME Heating, Cooling, Plumbing and Electrical can help get your home temperature where it needs to be.
And in the harsh winter months in Wayne County, MI, FLAME is your go-to provider of HVAC systems.
Did you know eliminating excess humidity from your home is essential to your family’s health and comfort? An Aprilaire whole-home dehumidifier is the answer for getting rid of mold, mildew, airborne bacteria, and musty odors. Contact FLAME, and give your family cleaner air today!
Call FLAME today, at (586) 217-2512, or sign up online, and we’ll call you!
Recent Jobs and Reviews in Ecorse , MI
Job Locations and Reviews
Completed furnace inspection and tune-up for rental certification on a 16-year-old unit located in the basement of a vacant property. System was found operating properly with no reported issues or deficiencies noted during the comprehensive inspection. All components tested within normal parameters and unit approved for certification.
Conducted on-site assessment of existing HVAC equipment for replacement estimate at residential property. Evaluated exterior-mounted utility connections, electrical meter infrastructure, and current system configuration including fuel type determination and equipment accessibility along building exterior. Documented existing conditions with photographic evidence showing weathered meter equipment, drainage systems, and outdoor unit placement area adjacent to brick structure for proper sizing and installation planning of replacement system.
Completed full HVAC system installation including a 70,000 BTU furnace and 2-ton air conditioning unit in basement utility closet with rear yard condenser placement. Installed new thermostat, condensate pump, and established all electrical connections at breaker panel with dedicated circuits for furnace and AC unit. Secured all required mechanical and electrical permits, reconnected existing ductwork, and remeasured return air for proper system airflow and efficiency.
Conducted comprehensive inspection of 10-year-old furnace system located in basement following reports of operational concerns. Upon examination, identified cracked heat exchanger requiring immediate shutdown for safety reasons. Evaluated existing R22 refrigerant air conditioning system and outdoor condensing unit positioned on concrete pad in backyard area. Provided full system estimate for complete HVAC replacement due to failed heat exchanger and obsolete R22 refrigerant technology, documenting equipment condition through photographic records of outdoor condensing unit installation, electrical connections, and refrigerant line routing.
Completed comprehensive tune-up and inspection on 10-year-old furnace system located in basement. During inspection, identified significant crack in supply plenum ductwork that requires immediate attention to prevent air loss and efficiency degradation. Documented aged and deteriorated insulation on main trunk line ductwork in attic space showing visible dirt accumulation and wear at connection points. Performed standard maintenance procedures including filter inspection, burner assembly cleaning, heat exchanger examination, blower motor lubrication, thermostat calibration, and combustion analysis to ensure safe and efficient operation. System is currently operational but recommend scheduling ductwork repairs to address the cracked plenum and consider re-insulating trunk line to restore proper thermal efficiency and airflow distribution throughout the home.
Responded to gas pressure concerns affecting entire residence in 70-year-old home. Performed comprehensive pressure test on gas line and meter assembly located in basement to identify potential leaks or pressure irregularities that had been present for approximately one week. Conducted thorough inspection of gas piping system throughout basement area, examining exposed black iron pipe runs, joints, and connections along ceiling joists and support beams. Utilized pressure testing equipment to pressurize gas lines and monitor for pressure drops indicating leaks. Testing apparatus was set up at exterior gas meter location to isolate and test the complete system from meter through interior distribution lines. Applied industry-standard pressure testing protocols, monitoring gauge readings over extended period to ensure system integrity. Inspected all visible pipe hangers, support clips, and connection points for proper installation and signs of deterioration consistent with age of home. D
Performed routine maintenance and inspection on a five-year-old main floor furnace unit with no reported operational issues. Conducted comprehensive tune-up including visual inspection of blower motor assembly, electrical connections, and wiring harnesses, verifying all components were properly secured and functioning within normal parameters. All systems tested and confirmed operational with no deficiencies noted.
Completed comprehensive Gold AC inspection on residential cooling system with equipment age over 10 years. Performed full system evaluation including outdoor condenser unit and attic-located air handler, verifying operational status, measuring system performance parameters, and inspecting all major components. Advised customer to maintain clear area around condenser unit free of debris for optimal airflow and system efficiency.
Conducted on-site assessment for air conditioning unit installation at residential property. Evaluated existing HVAC ductwork configuration in attic/crawlspace area, including rectangular metal supply ducts, air handler components, and flexible duct connections with foil-faced insulation. Inspected exterior electrical service panel and conduit routing on building exterior to verify electrical capacity and determine optimal placement for new AC condenser unit. Documented current system layout and utility connections through photographic documentation. Provided comprehensive equipment replacement estimate including recommended unit sizing, installation requirements, and necessary modifications to existing ductwork and electrical infrastructure to accommodate new air conditioning system.
Completed comprehensive Gold-level furnace inspection on 13-year-old unit located in basement. Performed thorough examination of all internal mechanical and electrical components including blower motor assembly, burner assembly, heat exchanger, electrical connections, and wiring harness. Verified proper operation of all system components and documented equipment condition with photographic records.
Performed routine maintenance tune-up on a gas furnace less than 5 years old located in basement. Conducted comprehensive inspection of all system components including gas valve, burner assembly, and electrical connections. Verified proper ignition sequence and observed clean blue flame pattern across burner ports, indicating optimal combustion. Inspected and replaced 16x25x1 air filter which showed dust accumulation. Checked all wiring connections, tested safety controls, and confirmed unit operating within normal parameters. No deficiencies or repairs required at this time.
Responded to water leak complaint in utility room. Upon inspection, identified leaking pipes connected to Rheem water heater. Assessed plumbing connections, valves, and supply lines for source of leak. Documented equipment condition and leak location through photo documentation of water heater, surrounding piping infrastructure, and HVAC system in mechanical space. Provided customer with findings and recommended repair options to resolve active leak condition.
Completed comprehensive A/C system inspection on residential cooling unit. Performed electrical diagnostics using clamp meter, recording amperage draw of 23.75 amps at condenser unit. Inspected indoor mechanical components including gas line connections with shutoff valve, PVC condensate drain system, and electrical wiring connections. Evaluated outdoor condenser unit condition, noting normal operational wear and proper electrical terminal connections. System operating within normal parameters at time of inspection.
Completed NSP AC inspection on 3-year-old system with basement coil and furnace. Verified operation of ASPEN refrigerant evaporator coil (Model DC24A3G-175L-416) containing R-410A refrigerant at 448 PSI design pressure. Inspected Honeywell Home air filter (Model FC100A1029, 16x25x4, MERV 11 rating) and provided customer education regarding proper filter maintenance intervals and MERV rating specifications for optimal system performance and air quality.
Responded to leak investigation and completed stack rebuild, toilet, and flange repair per approved estimate. Rebuilt plumbing stack system, replaced toilet flange, and reinstalled toilet assembly to resolve water leak issue. Verified all connections were properly sealed, tested system for leaks, and confirmed water supply was functioning correctly upon completion.
Completed installation of a new 70,000 BTU ECM furnace system with associated thermostat and condensate pump. Obtained mechanical and electrical permits prior to installation and ensured all work met local code requirements. Installed new PVC venting system, established proper electrical connections, configured gas supply lines, and verified all safety controls and operational parameters. System tested and confirmed operational, with utility rebate documentation submitted for energy-efficient equipment.
Provided estimate for complete furnace replacement following previous shutdown due to critical safety issues including seized inducer motor, failed blower motor with significant oil leakage, and cracked heat exchanger. The 10+ year old natural gas furnace located in basement was deemed non-operational and unsafe for continued use. Assessed existing ductwork configuration and utility connections to determine replacement specifications for new equipment installation.
Responded to service call for leaking downstairs wastewater pipe in basement area. Upon inspection, identified compromised PVC drainage piping running along concrete block foundation wall. Assessed plumbing system configuration including vertical and horizontal drain lines with multiple joints and fittings. Evaluated pipe connections and determined source of water leak in wastewater drainage system. Completed necessary repairs to eliminate active leak and restore proper drainage function. Verified system integrity and confirmed no additional moisture intrusion following repair completion.
Responded to service call for a clogged drain in basement laundry area that had been problematic for approximately 5 days. Upon inspection, removed floor drain cleanout access cap and identified significant buildup of debris restricting water flow. Successfully cleared the blockage using appropriate snaking equipment, restored proper drainage function, and documented the condition with photos before and during service.
Performed comprehensive tune-up on 12-year-old HVAC system located in basement. Noted previous water damage with visible flood mark on unit exterior. Conducted electrical diagnostics using multimeter, verifying proper voltage readings and electrical connections. System is operational but shows signs of age and previous water exposure.